Accucold VLT104 Manual de Usario

Lee a continuación 📖 el manual en español para Accucold VLT104 (21 páginas) en la categoría congelador. Esta guía fue útil para 6 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/21
COMMERCIAL MANUAL DEFROST CHEST
FREEZER
COMMERCIAL CONGÉLATEUR COFFRE AVEC
DÉGIVRAGE MANUEL
Models
VT133
VLT134
VT183
VLT184
VT203
VLT204
VT252
VLT253
VT73
VLT74
VT103
VLT104
Owner's Manual / Mode d’emploi
BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.
AVANT UTILISATION, S'IL VOUS PLAÎT LIRE ET SUIVRE LES RÈGLES DE SÉCURITÉ ET
INSTRUCTIONS D'UTILISATION.
Accucold Division of Felix Storch, Inc.
An ISO 9001:2015 registered company
770 Garrison Avenue
Bronx, NY 10474
www.accucold.com
2
TABLE OF CONTENTS
Important Safeguards 3-4
Installation Instructions 5
Before Using your Freezer 5
Installing your Freezer 5
Electrical Connection 5
Operating your Freezer 6-7
Temperature Control 6
Care of Frozen Items 6
Defrosting your Freezer 7
Care and Maintenance 8
Cleaning your Freezer 8
Vacations 8
Power Failure 8
Moving your Freezer 8
Energy-Saving Tips 8
Troubleshooting 9
Limited Warranty 10
French Translation of this Manual - 11 20
CALIFORNIA CARB/SNAP DISCLOSURE
This product uses eco-friendly hydrocarbon refrigerant and fully complies with California
CARB regulations.
However, we are required by California Law to provide the following disclosure statement in every
product sold in California.
"This equipment is prohibited from use in California with any refrigerants on the 'List of Prohibited
Substances' for that specic end-use, in accordance with California Code of Regulations, title 17,
section 95374. This disclosure statement has been reviewed and approved by Felix Storch, Inc. and
Felix Storch, Inc. attests, under penalty of perjury, that these statements are true and accurate."
This product does use any refrigerants on the 'List of Prohibited Substances'" not
3
IMPORTANT SAFEGUARDS
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read
and obey all safety messages.
This is the Safety Alert Symbol. This symbol alerts you to potential hazards that can kill or
injure you and others. All safety messages will follow the Safety Alert Symbol and either the
words” DANGER”, “WARNING” or “CAUTION”.
DANGER means that failure to heed this
safety statement may result in severe
personal injury or death.
WARNING means that failure to heed this
safety statement may result in extensive
product damage, serious personal injury,
or death.
CAUTION means that failure to heed this
safety statement may result in minor or
moderate personal injury, or property or
equipment damage.
Safety messages will alert you to what the potential hazard is, tell you how to reduce the chance of injury,
and let you know what can happen if the instructions are not followed.
Before your chest freezer is used, it must be properly positioned and installed as described
in this manual, so read the manual carefully. To reduce the risk of re, electrical shock or
injury when using the chest freezer, follow basic precautions, including the following:
The VT133 VT183 VT203, and VT252 are CFC- and HFC-free and contain a small quantity of , ,
propane (R290). The VT73 VT103 are CFC- and HFC-free and contains small quantity and a of
Isobutane (R600a) These are environmentally, but ammable. They do not damage the ozone .
layer, nor do they increase the greenhou eect. Care must be taken during transportation and se
setting up the appliance that no parts cooling system are damaged. Leaking coolant can of the
ignite and damage the eyes. may
In the event of any damage:
o Avoid open ames and anything that creates a spark
o Disconnect from the electrical power line
o Air the room in which the appliance is located for several minutes and
o Contact the Service Department for advice
The more coolant there is in an appliance, the larger the room it should be installed in. In the event of
a leakage, if the appliance is in a small room, there is the danger of combustible gasses building up.
The amount of coolant in the appliance is stated on the rating label on the appliance. It is hazardous
for anyone other than the Authorized Service Person to carry out servicing or repairs to the appliance.
Take serious care when handling, moving, and using the appliance to avoid either damaging the
refrigerant tubing or increasing the risk of a leak.
Replacing component parts and servicing shall be done by factory authorized service personnel so as
to minimize the risk of possible ignition due to incorrect parts or improper service.
Plug into a grounded 3-prong outlet. Do not remove grounding prong, do not use an adapter,
and do not use an extension cord.
Replace all panels before operating.
recommended that a separate circuit, serving only your chest freezer, provided. It is be
Use receptacles that cannot be turned o by a switch or pull chain.

Especificaciones del producto

Marca: Accucold
Categoría: congelador
Modelo: VLT104

¿Necesitas ayuda?

Si necesitas ayuda con Accucold VLT104 haz una pregunta a continuación y otros usuarios te responderán




congelador Accucold Manuales

congelador Manuales

Últimos congelador Manuales