IMPORTANT NOTE:
Please read this manual carefully before installing or operating your wired remote controller. Make sure to save this manual
for future reference.
Copy/
Follow me
Back/ oConfirm TurbDay off/DelTimerSwing
OWNER’S MANUAL
INSTALLATION &
Universal Wired Remote Controller
Model Number:
WC-02
That’s better. That’s Actron.
1. Safety Precaution..................................................................................... 3
2. Installation Components......................................................................... 4
3. Installation Method................................................................................. 5
4. Specification............................................................................................ 10
5. Wired Controller Features and Functions................................................ 11
6. Wired Controller Display......................................................................... 12
7. Wired Controller Buttons........................................................................ 13
8. Preparatory Operation............................................................................ 14
9. Operation................................................................................................ 15
10. Timer Functions .................................................................................... 20
11. Weekly Timer........................................................................................... 23
12. Fault Alarm Handing ............................................................................... 30
Table of Contents
Installation and Owners Manual
Page 2
Page 3
1. Safety Precautions Wired Remote Controller
WARNING
Carefully read the Safety Precautions before installation. Adhere to this installation manual.
Only trained and qualified HVAC technicians should install, repair and service this air conditioning unit, strictly follow the
installation instructions set forth in this manual. Improper installation may result in electrical shock, short circuit,
leaks, fire or other damage to the equipment and personal property.
Reinstallation must be performed by a qualified service technician.
WARNINGS FOR PRODUCT USE
DO NOT install the unit in a place vulnerable to leakage of flammable gases. If flammable gases leak or linger around the
wired controller, fire may occur.
CODES, REGULATIONS, AND STANDARDS
The installer/contractor assumes responsibility to ensure that the installation complies with the releveant council,
state/federal codes, regulations and building code standards. All electrical wiring must be in accordance with current
electrical authority regulations and all wiring connections to be as per the electrical diagram/s provided with the unit.
This manual gives detailed description of the precautions
that should be brought to your attention during operation.
To ensure the correct service of the wired controller
read this manual carefully before using the unit.
Keep this manual after reading for future reference.
This manual is a controlled document which contains confidential and proprietary information.
Distribution, modification, copying and/or reproduction are prohibited without written consent from ActronAir
Product design and specifications are subject to change without prior notice for product improvement.
Read Safety Precautions Before Installation
Thank you for purchasing this air conditioner. This manual will provide you with information on how to operate, maintain,
and troubleshoot your air conditioner. Following the instructions will ensure the proper function and extended lifespan of
your unit.
Please pay attention to the following signs:
WARNING
Failure to observe a warning may result in death or serious injury. The
appliance must be installed in accordance with national regulations.
Failure to observe a caution may result in injury or equipment damage.
MUST BE INSTALLED BY A
LICENSED ELECTRICIAN
D I Y
D Y
FOR COMPLIANCE WITH
QUEENSLAND ELECTRICAL SAFETY
REGULATIONS 2002
This refers to electrical works only

Especificaciones del producto

Marca: ActronAir
Categoría: aire acondicionado
Modelo: LRC-100CS
Color del producto: Zwart
Peso.: 2300 g
Ancho: 370 mm
Profundidad: 320 mm
Altura: 44 mm
Material de la carcasa: Metaal
red LAN: Ja
Formatos de compresión de vídeo: H.264, H.265, M-JPEG
Sistema de audio: 2-weg
Número de puertos USB 2.0: 2
Número de puertos HDMI: 1
Número de puertos Ethernet LAN (RJ-45): 1
Consumo de energía (máx.): 28 W
Certificación: UL, CE, FCC, KC
Formato de señal analógica: NTSC, PAL
Resolución máxima de vídeo: 3840 x 2160 Pixels
Salida de audio: 1
Tipo de comida: DC
Protocolos de red compatibles: TCP/IP, UDP/IP, RTP (UDP), RTP (TCP), RTSP, NTP, HTTP, DHCP (Server, Client), PPPoE, SMTP, ICMP, IGMP, ARP, DNS, DDNS, uPnP, HTTPS, SNMP, ONVIF (ProfileS), SUNAPI(Server, Client)
Tipo de interfaz Ethernet: Gigabit Ethernet
Idiomas soportados: CZE, DAN, DEU, DUT, ENG, ESP, FIN, FRE, GRE, HUN, ITA, JPN, KOR, NOR, POL, POR, RUM, RUS, SER, SWE, THA, TUR
Interfaz de disco duro: SATA
Control PTZ: Ja
Número de canales: 4 kanalen
Puertos de salida BNC: 1
Número máximo de HDD por gabinete: 2
Puertos de entrada BNC: 4
Puertos de salida VGA (D-Sub): 1
Canales de entrada de alarma: 4
Temperatura de funcionamiento (TT): 0 - 40 °C
Humedad relativa de funcionamiento (VV): 20 - 85 procent
Función de copia de seguridad: Ja
Tensión continua (CC): 12 V
Canales de salida de alarma: 2