Place the Back-UPS to avoid:
Direct sunlight
Excessive heat
Excessive humidity or contact with fluids
bu054a
ON/OFF and
LED Status
Indicator Battery backup and
surge protected outlets
2
3
990-3333B-005 © 2009 American Power Conversion Corp.
All other trademarks are property of their respective owners.
APC, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.
Connect the Battery and Turn on the Unit
Connect the battery to the UPS before use. To connect the battery:
Pull the top of the battery connector lever out of the unit, until the lever is horizontal.
Push the battery connector lever completely into the unit, until the end of the lever is flush with the rear panel.
Press ON/OFF to turn on the unit.
A single short beep, and the green “Power On” indicator confirms that the Back-UPS is on and ready to provide
protection.
The Back-UPS should charge for at least 10 hours to ensure sufficient runtime. The unit is being charged
whenever it is connected to utility power, whether the unit is turned ON or OFF.
Status Indicators
The Back-UPS indicates its operating status using a combination of visual and audible indicators.
Power On LED Buzzer Condition
On Off On-line - Back-UPS is supplying conditioned utility power
to the connected equipment
On (Off during 4
beeps) 4 beeps repeated
every 30 seconds
On-Battery - Back-UPS is supplying battery power
Flashing Rapid Beeping
(every 1/2 second)
Low Battery Warning - The Back-UPS has 1.5 minutes of
remaining battery power
Flashing Constant tone Bad Battery Detected - Battery needs to be charged, or is
at end of life. (See Battery Replacement.)
Off Short beep every
4 seconds
Low Battery Shutdown - During On Battery operation the
battery power was almost completely exhausted, and the
Back-UPS is waiting for utility power to return to normal
Off Constant Tone On Battery Overload - Connected equipment requires
more power than provided by the Back-UPS battery.
Unplug devices one at a time to remove overload, if not
corrected Contact APC Technical Support
On Constant Tone On Line Overload - The power drawn by the connected
equipment exceeds the power capacity of the Battery
Backup
Flashing Chirp every 2
seconds
Charger Warning -Back-UPS has experienced an internal
problem, but continues to power the load. Contact APC
Technical Support
Off Constant Tone Charger Fault - Back-UPS has an internal problem, and is
no longer powering the load. Contact APC Technical
Support
Adjusting Transfer
Voltage and Sensitivity
Settings
Automatic Voltage Regulation boosts the utility voltage
when it drops below safe levels. This allows the
equipment plugged into the unit to operate during low
voltage conditions, conserving the battery power in the
event of a power outage.
The Back-UPS will switch to battery power if the input
voltage level becomes too low for the Automatic
Voltage Regulation to compensate, or if the utility
power is distorted.
If the Back-UPS switches to battery power too
frequently or too infrequently, adjust the transfer
voltage and sensitivity settings:
1. Ensure the Back-UPS is off. Plug it into utility
power.
2. Press and hold ON/OFF until the LED repeatedly
flashes. The unit is now in Program Mode.
3. Release the button. The LED will flash once,
twice, or three times per second, indicating the
current setting. See Transfer Voltage and
Sensitivity Settings.
4. Press ON/OFF within two seconds to change the
setting. Each time the button is pressed, the LED
will flash at a different rate: once, twice, or three
times per second, indicating the new setting.
Continue pressing the button until the desired
setting is reached. If the button is not pressed
within five seconds, the Back-UPS will exit the
Program Mode.
5. To exit Program Mode, release the button and
wait for the LED to stop flashing.
Connect Equipment
Battery Backup Surge Protection
These outlets are powered whenever the Back-UPS is switched
ON. During a power outage, or other utility problems (brownouts,
over-voltages), these outlets will be powered for a limited time by
the Back-UPS. Plug the computer and monitor into these two
outlets.
Connect AC Power Cord
Plug the Back-UPS power cord into a wall outlet, not a surge
protector or power strip. The outlet should be near the equipment
and easily accessible.
Back-UPS® RS 500
BR500CI-AS User Guide
Transfer Voltage and Sensitivity Settings
LED Flashing Transfer Voltage
Setting
Input Voltage
Range
(For Utility
Operation)
Usage
Once per second Low 155 - 280 The Back-UPS will switch to battery power less often. Use with equipment that is not
sensitive to low or high level voltage levels or minor voltage waveform distortions.
Twice per second Medium
(factory default) 160 -280 Default, use in normal conditions.
Three times per second
High 165 - 270 The Back-UPS will switch to battery power during any small fluctuation in voltage.
Use with equipment that is sensitive to low or high level voltage levels or minor
voltage waveform distortions.
bu053a
Troubleshooting
Specifications
Input Voltage 230 Vac nominal
Frequency 45-65 Hz
Brownout Transfer 160 ±8% VAC, typical
Over-voltage Transfer 280 VAC, typical
Output UPS Capacity (total) 500 VA / 300 W
Voltage On Battery 230 Vac rms
(step-approximated sine wave)
Frequency - On Battery 50 Hz ±1 Hz, 60 Hz ±1 Hz
Transfer Time 50 Hz: 6ms typical, 10ms maximum
60 Hz: 5ms typical, 8ms maximum
Protection and
Filter AC Surge Protection Full time, 273 joules
AC Input Re-settable circuit breaker
Battery Type Maintenance free
Average Life 2 - 5 years depending on the number of discharge cycles and
environmental temperature
Typical Recharge Time 10 Hours
Physical Net Weight 5.4 kg
Dimensions (H x W x D) 18.55 cm (H) x 11.5 cm (W) x 21.3 cm (D)
Operating Temperature 0 oC to 40 oC (32 oF to 104 oF)
Storage Temperature -15 oC to 45 oC (5 oF to 113 oF)
Operating Relative
Humidity 0 to 95% non-condensing
Operating Elevation 0 to 3000 m (0 to 10,000 ft)
Service
Please DO NOT RETURN Back-UPS to the place of purchase under any circumstances.
1. Consult the Troubleshooting section to eliminate common problems.
2. If you still have problems or questions, please contact APC via the internet or at one of the phone numbers listed below.
3. Before contacting APC, please be sure to record the date purchased, UPS model, and serial number (on bottom of unit).
4. Be prepared to troubleshoot the problem over the telephone with a Technical Support Representative. If this is not successful, the representative will issue a Return
Material Authorization Number (RMA#) and a shipping address.
5. Pack the unit in its original packaging. If the original packaging is not available, ask APC Technical Support about obtaining a new set. Pack the unit properly to avoid
damage in transit. Never use foam beads for packaging. Damage sustained in transit is not covered under warranty (insuring the package for full value is
recommended).
6. Write the RMA# on the outside of the package.
7. Return the unit by insured carrier to the address given to you by APC Technical Support.
APC Worldwide Customer Support
Technical Support http://www.apc.com/support
Internet http://www.apc.com
Worldwide +1 800 555 2725
Problem Probable Cause Solution
Back-UPS will not turn on. Circuit Breaker has tripped. Reduce the amount of equipment plugged into the “Battery Backup + Surge Protection
outlets. Reset the circuit breaker by pushing it back in.
Utility power is not available at the wall
outlet. Ensure the fuse or circuit breaker for the wall outlet is okay, and the wall switch controlling
the wall outlet (if any) is in the ON position.
Connected equipment loses
power. The Back-UPS is overloaded. Ensure the equipment plugged into the outlets of the unit are not overloading the capacity
of the unit. Try disconnecting some of the equipment one device at a time, and see if the
problem continues.
The Back-UPS has exhausted its available
battery power. The unit can only operate on battery power for a limited amount of time. The unit will
eventually turn off when the available battery power has been used. Allow the unit to
recharge for 10 hours before continuing to use the unit.
The equipment connected to the Back-UPS
does not accept the step-approximated sine
waveform from the unit.
The output waveform is designed for computers and computer-related equipment. It is not
designed for use with motor-type equipment.
The Back-UPS may require service. Contact APC Technical Support for further troubleshooting.
The ON/OFF button is lit, and
the unit is beeping four times
every 30 seconds, or it is
emitting a constant tone.
The unit is using battery. The unit is operating normally and using battery power. Save any current work, turn off all
equipment, and turn the unit OFF. Once normal power is restored, turn the unit back ON,
and turn on all equipment.
The On/Off button flashes once
per second, and the Back-UPS
beeps once per second at the
same time.
Battery capacity is low (there is about 2
minutes of use remaining). The unit is about to shut down due to a low battery charge condition! When the unit beeps
once every second, the battery has about 2 minutes of power remaining. Immediately
power down your computer, and turn the unit OFF. When power returns to normal, the unit
will recharge the battery.
Inadequate runtime. The battery is not fully charged. Allow the unit to charge by leaving it plugged in, and switched on for 10 hours.
The battery is near the end of useful life. As a battery ages, the amount of runtime available will decrease. Batteries also age
prematurely if the unit is placed near excessive heat. If the battery will not charge, the
Back-UPS is no longer operable.
Battery Replacement
The battery in the Back-UPS 500 is not user-replace-
able. Contact APC Sales and Technical Support for a
list of authorized service centers near you.
Warranty
The standard warranty is 2 years from the date of
purchase. The APC standard procedure is to replace the
original unit with a factory reconditioned unit. APC will
ship the replacement unit once the defective unit is
received by the repair department or cross-ship upon the
provision of a valid credit card number. The customer
pays for shipping to APC, and APC pays ground freight
transportation costs back to the customer. Customers
who must have the original unit back due to assigned
asset tags and set depreciation schedules must declare
such a need at first contact with APC Technical Support.
Indonesia 0800 1088 088
Malaysia 1800 80 1030
Philippines 1800 1651 0302
Singapore +65 6389 6823
Thailand 001 800 65 6340
Vietnam (1201 0288) 1 888 576 6432
1
Tránh để Back-UPS nơi có:
N ế ự ếng chi u tr c ti p
Nhit độ quá cao
Độ m quá cao hoc tiếp xúc vi các cht lng
bu054a
Nút ON/OFF
v
à Đèn LED
Báo Trng thái Các cm c quy d
phòng chng sc đi
n
2
3
990-3333B-036 © 2009 American Power Conversion Corp.
Tt c các thương hiu khác là tài sn ca các ch s hu tương ng ca chúng.
APC, Back-UPS và PowerChute là các thương hiệ đ u ã đăng ký c a American Power Conversion Corp.
N ii c quy vào và Bt B Lưu đ ện lên
Ni c quy vào UPS trước khi s dng. Để ni c quy:
1 Kéo đầ đếu c ư đ ện n i c quy ra ngoài b l u i n, cho n khi cầ ằn n m ngang.
2 iĐẩy hết cn ni c quy vào trong b lưu đ ện, cho đến khi cán ca nó ngang bng vi mt sau.
Nhn ON/OFF để bt b lưu đ ệi n.
Thiết b phát ra mt tiếng bíp ngn, và đèn báo "Ngun B ế ằ đ t" màu xanh cho bi t r ng Back-UPS ã b t và s n
sàng hot động.
Back-UPS cầ ạn được s c ít nht 10 tiếng đồng h để đả m bo p đủ c đ ệ ư đ ệi n. B l u i n đưc sc bấ ứt c lúc nào
có ngu đ ện i n cp cho nó, cho dù đang BT hay TT.
Các Ch th Trng thái
Back-UPS biu thnh trng ho ng ct độ ủa nó bng cách sử ụ d ng kết h thp các chỉ ị nghe và nhìn.
Đ ồ èn LED Ngu n Âm báo Tình tr ng
Bt T đ đ ệ tĐ ệi n lưới - Back-UPS ang c p i n ngu n hi u d ng công
sut cho thiết b kết ni
Bt (Tt trong sut
4 tiếng bíp)
4 tiếng bíp lặ ạp l i
mi 30 giây
Đ ệ i n c quy - Back-UPS đ đ ệ ang c p i n t ngu n c quy
Chp liên tc Tiếng bíp phát
liên tc
(mi 1/2 giây)
Cnh báo Gn Hết c quy - Back-UPS còn li 1,5 phút
c p i n đ ệ
Chp liên tc Tông đuPhát hiệ Ắn c quy Không n - ạ ặc quy c n đưc s c, ho c
đ ế ã h t tu i th . (Xem Thay c quy.)
Tt Tiế ắng bíp ng n
mi 4 giây
Ngt ngun Do Sp hết c quy - Trong sut quá trình hot
độ ủ Ắng c a c quy, ngu đ ệ n i n c a c quy h ư đu nh ã cn
kit, và Back-UPS đang chờ ấ đ c p ngu n hi u d ng tr v
hot động bình thường
T t Tông u đề Quá t ế Đ ệ i Ch độ ng i n c quy - c quy ca Back-
UPS không đ sc c c s đ ệp i n cho thiết bị đ ang đượ ử ụ d ng.
Rút t ra ng thiết bị đ gim ti, nếu vẫ ắn không kh c phc
đượ ỗ ợ c Hãy Liên h H tr K thu t cậ ủa APC
Bt Tông đều Quá t ế Đ ệi Ch độ ng i n Lưới - Thiết b kết ni tiêu
thụ đ i n vượt quá công sut ca c quy D phòng
Chp liên tc Kêu nhỏ ỗ m i 2 giây C cnh báo B s - Back-UPS trc trc bên trong, nhưng
vn tiếp tc cp ngun cho ti. Hãy liên h H tr K thut
ca APC
T ụ ặt Tông đềuL ci B s - Back-UPS tr c tr c bên trong, và không n
cp ngun cho ti. Hãy liên h H tr K thut ca APC
Đ ề Đ ệi u ch nh i n áp
Chuyn và Các Thiết
l yp Độ nh
ă đ ệ n áp T động t ng i n áp hi u d ng khi nó t t dưới
m i c an toàn. Đ ều này cho phép thiết b cm vào b
l i iưu đ ện tiếp tc vn hành trong sut thi gian đ ện áp
thp, bo tn ngun c quy trong trường hp m đ ệt i n.
The Back-UPS s chuyn sang dùng ngun c quy nếu
điệ ấn áp ngõ vào quá th p đến mc n áp T động kng
đưc, hoc nếu ngun hi u dệ ụng kng n nh.đị
Nếu Back-UPS chuyn sang ngun c quy quá
thường xuyên hoc ít khi, hãy đ ềi u chnh đ ệi n áp
chuyn và các thiết lp độ nhy:
1. Hãy chắ ắc ch n rng Back-UPS đã tt. Cm
vào ngun hiu dng.
2. Nhấ ữ đn và gi ON/OFF cho đến khi èn LED
chp liên lc. B lưu ang đ ệi n y giờ đ ở ế Ch
đ Lp trình.
3. Th t ra. Đèn LED s ch ộ ầ p m t l n, hai l n,
hoc ba ln mi giây, biu th thiết lp hin hành.
Xem Đ ệ ế i n áp Chuy n và Các Thi t l p Độ nh y.
4. Nhn ON/OFF trong vòng hai giây để thay đổi
thiết lp. Mi ln nhn nút, đèn LED s chp vi
m c t mứ độ khác nhau: mt ln, hai ln, hoc ba
ln mi giây, biu th thiết lp m p ti. Tiế ục nhn
nút cho đến khi có được thi p theo ý muết lậ ốn.
Nếu trong năm giây không nhn nút, Back-UPS
s thoát khi Chế độ Lp trình.
5. Đ thoát khi Chế độ Lậ ảp trình, hãy th nút ra
ch cho đến khi đèn LED ngưng không chp na.
Kết ni Thiết b
đ ệc quy D phòng Ch ng S c i n
Các cm này có đ ệi n bt c khi nào BT Back-UPS n. Trong
lúc m đ ệt i n, hay khi có các trc trc thc tế ặ ư hay g p khác (nh
t it áp, quá áp), Back-UPS s cp đ ện ra các cm này trong
khong thi gian có giớ ạ i h n. C m máy tính và màn hình vào
các cm này.
Ni Dây Ngun AC
C im dây ngun ca Back-UPS vào cm đ ện trên tường,
không cm vào bộ ố ch ng s đ ệc i n ho ổ ắc c m rờ Ổ ắi. c m nên
gn thiết b và d cm.
B lưu đin Back-UPS
®
RS 500
H iướng dn S dng B lưu đ ện BR500CI-AS
Đ ệ ế i n áp Chuy n và Các Thi t l p Đ nh y
Đ ớèn LED ch p Thiết lp Đ ệi n áp
Chuyn
Phm vi Đ ệi n áp
Ngõ vào
( iĐ ện áp Hiu dng) Công dng
M n t ln mt giây Thp 155 - 280 Back-UPS s ít thường xuyên chuyn sang nguồ ắc quy hơn. Dùng vi thiết b không
nhạ ảy c m vi các mc đ ệi n áp cao hay thấ ặp ho c các nhiu sóng đ ệi n áp nh.
Hai ln mt giây Trung bình
(mc đnh khi xut
x ng)ưở
160 -280 Mặ địc nh, dùng trong đ ềi u kin bình thường.
Ba lầ ộn m t giây Cao 165 - 270 Back-UPS s chuyn sang nguồ ắn c quy trong sut thi gian có bt c dao độ đ ệng i n
áp nh nào. Dùng vi thi t bế ị nh i các mạ ảy c m v đ ệc i n áp cao hay thấ ặp ho c các
nhiu sóng đ ệi n áp nh.
bu053a

Especificaciones del producto

Marca: Apc
Categoría: Unión Postal Universal
Modelo: Back-UPS 500VA

¿Necesitas ayuda?

Si necesitas ayuda con Apc Back-UPS 500VA haz una pregunta a continuación y otros usuarios te responderán




Unión Postal Universal Apc Manuales

Unión Postal Universal Manuales

Últimos Unión Postal Universal Manuales