Apc Back-UPS Pro BR1500MS2 Manual de Usario
Apc
Unión Postal Universal
Back-UPS Pro BR1500MS2
Lee a continuación 📖 el manual en español para Apc Back-UPS Pro BR1500MS2 (12 páginas) en la categoría Unión Postal Universal. Esta guía fue útil para 10 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/12
Important Safety Instructions
Inspect the package contents upon receipt. Notify the carrier and
dealer if there is any damage.
SAVE THESE INSTRUCTIONS - This section contains important
instructions that should be followed during installation and maintenance of
the UPS and batteries.
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
• This UPS is intended for indoor use only.
• Do not operate this UPS in direct sunlight, in contact with fluids, or
where there is excessive dust or humidity.
• Be sure the air vents on the UPS are not blocked. Allow adequate
space for proper ventilation.
• Connect the UPS power cable directly to a wall outlet.
Failure to follow these instructions will result in death or serious
injury.
CAUTION
RISK OF HYDROGEN SULPHIDE GAS AND EXCESSIVE SMOKE
• Replace the battery at least every 5 years or at the end of its service
life, whichever is earlier.
• Replace the battery immediately when the UPS indicates battery
replacement is necessary.
• Replace batteries with the same number and type of batteries as
originally installed in the equipment.
• Replace the battery immediately when the UPS indicates a battery
over-temperature condition, or when there is evidence of electrolyte
leakage. Power off the UPS, unplug it from the AC input, and
disconnect the batteries. Do not operate the UPS until the batteries
have been replaced.
Failure to follow these instructions could result in minor or
moderate injury and equipment damage.
User Manual Back-UPS™ Pro
BR1500MS2
Back-UPS Pro BR1500MS22
Inventory
Connect the Battery
The UPS is shipped with the battery disconnected.
Coaxial Cable
USB communication cable
Lay the UPS with the battery door facing up.
The arrows point to the locking tabs of the
battery compartment.
Press the tabs downwards and pull the
battery door away from the unit to access
the battery modules.
Using the handles on both sides of the
battery, lift the battery 30 degrees upward to
expose the battery connector. Connect the red
wire as shown above.
Push the battery into the unit.
Replace the battery door.
bu476a
bu471a
bu472a
bu473a
bu474a
b
u
4
7
5
a
Back-UPS Pro BR1500MS2 3
Install PowerChute™ Personal Edition Software
Use PowerChute Personal Edition software to configure the UPS settings.
During a power outage, PowerChute will save any open files on your
computer and shut it down. When power is restored, it will restart the
computer.
Note: PowerChute is only compatible with a Windows operating system. If
you are using Mac OSX, use the native shutdown feature to help protect your
system. See the documentation provided with your computer.
Installation
Use the USB communication cable supplied with the Back-UPS to connect
the data port on the Back-UPS to the USB port on your computer. On the
computer, go to www.apc.com Search for “PowerChute Personal Edition”
then click on “View Details” to download the latest version of PCPE
software. Click the download link and select Software product. Select the
appropriate operating system. Follow directions to download the software.
Connect the Equipment
Battery Backup and Surge Protected outlets
When the Back-UPS is receiving input power, the Battery Backup with
Surge Protection outlets will supply power to connected equipment. During
a power outage or other detected AC problems, the Battery Backup outlets
receive power for a limited time from the Back-UPS.
Connect equipment such as printers, fax machines, scanners, or other
peripherals that do not need battery backup power to the Surge Protection
Only outlets. These outlets provide full-time protection from surges even if
the Back-UPS is switched OFF.
Especificaciones del producto
Marca: | Apc |
Categoría: | Unión Postal Universal |
Modelo: | Back-UPS Pro BR1500MS2 |
¿Necesitas ayuda?
Si necesitas ayuda con Apc Back-UPS Pro BR1500MS2 haz una pregunta a continuación y otros usuarios te responderán
Unión Postal Universal Apc Manuales
18 Octubre 2024
12 Octubre 2024
12 Octubre 2024
12 Octubre 2024
12 Octubre 2024
12 Octubre 2024
12 Octubre 2024
12 Octubre 2024
12 Octubre 2024
4 Octubre 2024
Unión Postal Universal Manuales
- Unión Postal Universal AEG
- Unión Postal Universal IKEA
- Unión Postal Universal HP
- Unión Postal Universal Lenovo
- Unión Postal Universal Tripp Lite
- Unión Postal Universal Energenie
- Unión Postal Universal Voltcraft
- Unión Postal Universal Adj
- Unión Postal Universal Digitus
- Unión Postal Universal LevelOne
- Unión Postal Universal Eaton
- Unión Postal Universal CyberPower
- Unión Postal Universal Block
- Unión Postal Universal Avocent
- Unión Postal Universal Minuteman
- Unión Postal Universal Maruson
- Unión Postal Universal V7
- Unión Postal Universal Phoenix Contact
- Unión Postal Universal Puls Dimension
- Unión Postal Universal Salicru
- Unión Postal Universal Equip
- Unión Postal Universal Murr Elektronik
- Unión Postal Universal Altronix
- Unión Postal Universal Ditek
- Unión Postal Universal Bxterra
- Unión Postal Universal Middle Atlantic
- Unión Postal Universal FSP
- Unión Postal Universal Atlantis Land
- Unión Postal Universal PowerWalker
- Unión Postal Universal FSP/Fortron
- Unión Postal Universal Online USV
Últimos Unión Postal Universal Manuales
24 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
20 Octubre 2024
18 Octubre 2024
11 Octubre 2024
9 Octubre 2024
9 Octubre 2024
6 Octubre 2024