Apc Easy UPS SMV1000A Manual de Usario

Apc Unión Postal Universal Easy UPS SMV1000A

Lee a continuación 📖 el manual en español para Apc Easy UPS SMV1000A (8 páginas) en la categoría Unión Postal Universal. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/8
User Manual UPSEasy
SMV Series 750, 1000, 1500, 2000, 3000 VA
DANGER
DANGER
DANGER
DANGER DANGER
W
W
W
WW
A
A
A
AAR
R
R
RRN
N
N
NNI
I
I
IIN
N
N
NNG
G
G
GG
CAUTION
CAUTION
CAUTION
CAUTION CAUTION
SAVE THESE INSTRUCTIONS - This section contains important instructions that should be followed
during installation and maintenance of the UPS and batteries.
Read these instructions carefully and look at the equipment to become familiar with the device before
trying to install, operate, service or maintain it. The following special messages may appear throughout
this document or on the equipment to warn of potential hazards or to call attention to information that
clarifies or simplifies a procedure.
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious
injury.
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious
injury.
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate
injury.
NOTICE is used to address practices not related to physical injury.
Important Safety Messages
Product Handling Guidelines
The addition of this symbol to either a “Danger” or “Warning” safety label indicates that an
electrical hazard exists which will result in personal injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey
all safety messages that follow this symbol to avoid possible injury or death.
<18 kg
<40 lb
18-32 kg
40-70 lb
32-55 kg
70-120 lb
>55 kg
>120 lb
NOTICE
Easy UPS SMV Series 750, 1000, 1500, 2000, 3000VA
2
ŸAdhere to all national and local electrical codes.
ŸThis UPS is intended for indoor use only. To prevent the risk of fire or electric shock, install in a
temperature and humidity controlled indoor area, free of conductive contaminants.
ŸMains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily
accessible.
ŸUPS must be connected to an earthed mains socket outlet.
ŸConnect the power cable directly to a wall outlet. Do not use surge protectors or extension cords.
ŸCAUTION This UPS is designed to satisfy all of requirement of PCs only.
ŸCAUTION Risk of electric shock, do not remove the chassis cover. Servicing should be performed
by Qualified Engineer.
CAUTION
ŸReplacethebatteryatleastevery5years.
ŸReplacethebatteryimmediatelywhentheUPSindicatesbatteryreplacementisnecessary.
ŸReplacebatteryattheendofitsservicelife.
ŸReplacebatterieswiththesamenumberandtypeofbatteriesasoriginallyinstalledintheequipment.
ŸReplacethebatteryimmediatelywhentheUPSindicatesabatteryover-temperaturecondition,or
UPSinternalover-temperature,orwhenthereisevidenceofelectrolyteleakage.PowerofftheUPS,
unplugitfromtheACinput,anddisconnectthebatteries.DonotoperatetheUPSuntilthebatteries
havebeenreplaced.
Failure to follow these instructions can result in injury
ŸServicing of user replaceable batteries should be performed or supervised by personnel
knowledgeable about batteries and required precautions. In this case batteries are not user
replaceable.
ŸWhen replacing battery the UPS must be OFF, and its AC inlet unplugged.
ŸCAUTION Do not dispose of batteries in a fire. The batteries may explode.
ŸCAUTION Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries
according to the instructions.
ŸDo not open or mutilate batteries. They contain an electrolyte that is toxic and harmful to the skin
and eyes.
ŸCAUTION A battery can present a risk of electrical shock and high short circuit current. The
following precautions should be observed when working on batteries.
a. Remove watches, rings or other metal objects.
b. Use tools with insulated handles.
c. Wear rubber gloves and boots.
d. Do not lay tools or metal parts on top of batteries.
e. Disconnect the charging source prior to connecting or disconnecting battery terminals.
f. Determine if battery is inadvertently grounded. If inadvertently grounded, remove source from
ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood
of such shock can be reduced if such grounds are removed during installation and maintenance.
Safety and General Information
General safety
Battery safety
HYDROGEN SULPHIDE GAS AND EXCESSIVE SMOKE
ŸCAUTION The UPS contains internal batteries and may present a shock hazard even when
disconnected from AC power.
ŸCAUTION Risk of electric shock, Battery Circuit is not isolated from AC input, hazardous voltage
may exist between battery terminals and ground. Test before touching.
Radio Frequency Warning
This is a category C2 UPS product. In a residential environment, this product may cause radio
interference, in which case the user may be required to take additional measures.
Inventory
Software, User documentation
3
USB cable
Easy UPS SMV Series 750, 1000, 1500, 2000, 3000VA

Especificaciones del producto

Marca: Apc
Categoría: Unión Postal Universal
Modelo: Easy UPS SMV1000A

¿Necesitas ayuda?

Si necesitas ayuda con Apc Easy UPS SMV1000A haz una pregunta a continuación y otros usuarios te responderán




Unión Postal Universal Apc Manuales

Unión Postal Universal Manuales

Últimos Unión Postal Universal Manuales