Apc Smart-UPS SRT192BP Manual de Usario

Apc Unión Postal Universal Smart-UPS SRT192BP

Lee a continuación 📖 el manual en español para Apc Smart-UPS SRT192BP (20 páginas) en la categoría Unión Postal Universal. Esta guía fue útil para 8 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/20
Installation Guide Smart-UPS On-Line
External Battery Pack SRT192BP/
SRT192BP2/SRT192BPJ/SRT192BP2J
Safety Messages
SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during
installation and maintenance of the Smart-UPS and batteries.
Read these instructions carefully and look at the equipment to become familiar with the device before trying to install,
operate, service or maintain it. The following special messages may appear throughout this bulletin or on the equipment
to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.
The addition of this symbol either to a “Danger” or “Warning” safety label indicates that an electrical
hazard exists which will result in personal injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety
messages that follow this symbol to avoid possible injury or death.
Product Handling Guidelines
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious
injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious
injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate
injury.
NOTICE
NOTICE is used to address practices not related to physical injury.
<18 kg
<40 lb
18-32 kg
40-70 lb
32-55 kg
70-120 lb
>55 kg
>120 lb
Smart-UPS On-Line External Battery Pack SRT192BP/SRT192BP2/SRT192BPJ/SRT192BP2J2
Safety and General Information
Adhere to all national and local electrical codes.
Changes and modifications to this unit not expressly approved by APC by Schneider Electric could void
the warranty.
This unit is intended only for indoor use in a controlled environment.
Do not operate this unit in direct sunlight, in contact with fluids, or where there is excessive dust or humidity.
Be sure the air vents on the unit are not blocked. Allow adequate space for proper ventilation.
The UPS and external Battery Pack(s) must be properly grounded to each other and to the mains grounding
system.
Before installing or replacing the batteries, remove jewelry such as wristwatches and rings.
High, short circuit current through conductive materials could cause severe burns.
The battery typically lasts for two to five years. Environmental factors impact battery life. Elevated ambient
temperatures, poor quality mains power, and frequent short duration discharges will shorten battery life.
Replace the battery immediately when the UPS indicates battery replacement is necessary or when the batteries
reach the end of their life. Failure to do so could result in equipment damage and/or injury.
The UPS will recognize as many as 10 XLBPs connected to the UPS.
Note: For each XLBP added, increased recharge time will be required.
The equipment is heavy. Always practice safe lifting techniques adequate for the weight of the equipment.
The batteries are heavy. Remove the batteries before installing the UPS and external battery packs (XLBPs) in a
rack.
Always install XLBPs at the bottom in rack-mount configurations. The UPS must be installed above the XLBPs.
Do not dispose of batteries by burning them. The batteries may explode.
Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes, and may be toxic.
Always recycle used batteries.
Recycle the package materials or save them for reuse.
Additional safety information can be found in the Safety Guide supplied with this unit.
Overview
To verify that installation of an external battery pack (XLBP) has been successful, go to the UPS display
interface.
Perform an Alarm Test to determine if the XLBP is recognized by the UPS.
The LED on the XLBP will flash if successful communication has been established.
When viewing the status of an XLBP on the UPS display interface screen, the LED on the corresponding XLBP
will flash.
When an RBC needs to be replaced, perform a Runtime Calibration Test to verify that battery replacement is
required.
Smart-UPS On-Line External Battery Pack SRT192BP/SRT192BP2/SRT192BPJ/SRT192BP2J 3
Package Contents
Inspect the contents upon receipt. Notify the carrier and dealer if there is damage.
Included with all models
Front bezel Ground cable
2 pan head screws to secure
the ground cable
2 tie brackets
4 flat head screws to secure tie
brackets
1 pan head screw to secure
the XLBP battery cable
connector to an XLBP or to
the UPS.
Included with SRT192BP/SRT192BP2/SRT192BPJ only
User Documentation CD
Included with SRT8K/SRT10K models only
Battery communication (BATT COMM) cable
Included with SRT5K/SRT6K Tower models only
Stabilizer brackets are supplied with the SRT5K/SRT6K
models
The XLBP includes 1 stabilizer bracket connector
4 flat head screws to secure tower stabilizer brackets to the
UPS
Included with Rack-Mount models only
Rail Kit with instructions and hardware for installing rails in
a rack
1 pair rack-mount brackets
8 flat head screws to secure rack-mount brackets to the UPS
4 ornamental screws to secure rack-mount brackets to the
rails
2 cage nuts
Us e r D oc umen tation
su0434a
x8
x4
x2

Especificaciones del producto

Marca: Apc
Categoría: Unión Postal Universal
Modelo: Smart-UPS SRT192BP

¿Necesitas ayuda?

Si necesitas ayuda con Apc Smart-UPS SRT192BP haz una pregunta a continuación y otros usuarios te responderán




Unión Postal Universal Apc Manuales

Unión Postal Universal Manuales

Últimos Unión Postal Universal Manuales