Atosa Commercial MMF9109 Manual de Usario

Atosa No categorizado Commercial MMF9109

Lee a continuación 📖 el manual en español para Atosa Commercial MMF9109 (2 páginas) en la categoría No categorizado. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/2
Angle Curved Top Chest Freezer
(Glass Arc )Lid
Standard Features
Spec Sheet (unit : inch)
Model
Doors
Cu.Ft
Exterior
Voltage Watts
Net
Weight
WxDxH (inches)
MMF -9109
1 9.2 39 27 34 3/4 1/2 115/60/1 215W
125 lbs
MMF -9112 1 12.7 49 27 34 3/5 3/4 1/2 115/60/1 310W 147 lbs
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Atosa Glass Lid Curved Top Freezers are uniquely designed
for perfect storage of ice cream and all types of frozen
merchandise and easonal specialties. s
3 inch insulation foam wall secure good cold effect by
environmentally friendly r(134A) efrigeration system.
Maintains -10
°
°
°
°° -
-
-
-- )
)
)
)) -1°
-1°
-1°
-1°-1°
F(
F(
F(
F(F( 23.33
23.33
23.33
23.3323.33
to
to
to
to to F,
F,
F,
F,F,
ideal for both ice cream
and frozen food.
Exterior -white pre coated steel cabinet is durable and
permanent with big radius stylish blue plastic top and lid
frames.
Interior white -pre coated aluminum has NSF Sanitation
approved, and is durable and easy to clean.
Tempered glass slide lids with reflective film r educes solar
heat gain, enhances energy efficiency and minimizes
condensation.
Door locks standard provide security prevents theft.
Convenient defrost drain for easy cleaning.
2” (50MM)diameter stem castors.
MMF9112
MMF9109
Plan View
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Terms and Conditions
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
What is Not Covered y This Warrantyb
Atosa's sole obligation unde y e e e er this warrant is Iimit d to ith r r pair or
re ement m eplac of parts, subject to the additional li itations b low This warranty
ne e es e e eith r assum nor authoriz s any p rson to assume obligations oth r than
those expre ered by ssly cov this warranty.
Routine Maintenance requirements must be followed or warranty is v oid
NO CONSEQUENTIAL DAMAGES: ATOSA lS NOT RESPONSIBLE FOR
ECONOMIC LOSS; PROFIT LOSS; OR SPECIAL. IN DIRECT, CONSEQUENTIAL OR
DAMAGES, INCLUDING WITHOUT LIMITATION, LOSSES.
OR DAMAGES
ARISING FROM FOOD OR PRODUCT SPOILAGE, REGARDLESS OF WHETHER OR
NOT THEY RESULT FROM REFRIGERATION FAILURE.
WARRANTY IS NOT TRANSFE :RABLE This warranty is not assignable and
applies only in favor of user to whom delivered. /the original purchase ANY
SUCH G E E E ASSI NM NT OR TRANSF R SHALL VOID TH WARRANNTIE HERES IN
AND SHALL VOID ALL WARRANTIES. EXPRESS OR IMPLIED. INCLUDING ANY
WARRANTY OF MERC ANTABILITY OR LABOR COVERH AGE FOR COMPONENT
FAILURE OR OTHER THE WARRANTY PACKET PROVIDED WITH THE UNIT.
ALTERATION. NEGLECT. ABUSE. MISUSE, ACCIDENT, DAMAGE
DURING TRANSIT OR INSTALLATI N, FIREO , FOOD, OR ACTS OF G OD:
Atosa is not re e e eme e sponsible for the r pair or r plac nt of any parts that ar
determined to have been subjected after the date of manufacture to , alteration
neglect accident, , , abuse misuse , damage during transit or installation, , fire
flood, or act of God.
IMPROPER ELECTRICAL CONNECTIONS: Atosa IS NOT RESPONSIBLE FOR
THE REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS
RESULTING FROM ELECTRICAL POWER FAILURE, THE USE OF EXTENSION
CORDS, , LOW VOLTAGE OR VOLTAGE DROPS TO THE UNIT.
THE ONE (1) YEAR PARTS & LABOR WARRANTY AND THE ADDITI ONAI. FOUR
(4 E E) Y AR COMPR SSOR WARRANTY ARE DE E ESAS SCRIB D ABOVE. TH E
WARRANTIES ARE LEXC USIVE AND IN LIEU OF ALL. OTHER WARRANTIES
,
INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY OR FITNESS FOR
APARTICULAR PURPOSE. THERE ARE NO WARRANTIES WHICH EXTEND
BEYOND THE DESCRIPTION ON THE FACE HEREOF.
Outside U.S. and Canada: This warranty e e tdo s nor apply to ar as ou side the
continent of the Unite e e y d Stat s. Atosa is not r sponsible for any warrant claims
made on products sold or us d in such are eas.
*In some cases. a 25 % restocking fee may be charged to a buyer for returned
items.*
1 YEAR WARRANTY
All claims for eparts or labor must be made dir ctly through Atosa. All claims must
include: model number of the unit. the serial number. proof of purchase, date of
installation. and all pertinent information supporting the alleged defect In case .
of compressor replaceme nt under warranty. either compressor or compressor
tag must be returned to Atosa along with above listed information. Failure to
comply ith claims. w warranty policies will result in voiding
One Year Parts & Labor Warranty
Atosa warrants all new refrigerated components. such as the cabinet and all
parts to be free from defects in materials or workmanship. Atosa's obligation
under this warranty tis limited to a period of one(1)years from he date of original
inst f allation or 15 months a ter shipment date from Atosa. whichever occurs first.
All parts covered under this warranty that are defective within o ) year ofne (1
original installation or 5twenty five (2 ) months after shipment date from
manufacturer, , whichever occurs first are limited to repair or replacement
(including labor charges, defe e es)of ctive parts or ass mbli The labor warranty shall
include standard s only and r estraight time labor charg easonable e trav l time, as
determine y d b Atosa
Additional Four Year Compressor Warranty
In addition to the one (1) Year warranty e estat d abov . Atosa warrants its se eal d
compre e efessor to be fr e from d cts in both mate erial and workmanship und r
normal and proper use and maintenance service (4for a period of four )
additional y ears from the date of original installation but not to exceed five (5)
years. Compressors that have been determined to be defective from Atosa within
this extended period will be either repaired or replaced with a compressor or
compressor parts of similar design and capacity according to Atosa's discretion
The three (3) year extended compressor warranty applies only to sealed parts of
the compressor and does not apply to any other parts or components This
includes. the cabinet, paint finish. temperature cont , , rol refrigerant metering
device r , moto starting equipment an assembl, f y. and other electrical
componen etc.ts,
404A / 134a Compressor Warranty
The f -ive year compressor warranty detailed above will be void fif the ollowing
procedure is not carefully adhered to:
1 .This system contains R404A or R134a refrigerant and lubricant. The lubricant
has rapid oisture absorbing qualitim es.
2.Drier re eme e e en e plac nt is v ry important and must be chang d wh a syst m is
opened for se rvicing.
3.Micron level vacuums must be achi d to insueve re low moisture leve ls
in the s sy tem.
4.Compressor must be obtain d through Atosa. unl ss othe e e e erwise sp cifi d in