Blodgett BCX-14E Manual de Usario

Blodgett horno BCX-14E

Lee a continuación 📖 el manual en español para Blodgett BCX-14E (12 páginas) en la categoría horno. Esta guía fue útil para 4 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/12
BCX-14G, BCX-14E, BX-14G, BX-14E,
CNVX-14G AND CNVX-14E
INSTALLATION - OPERATION - MAINTENANCE
BLODGETT OVEN COMPANY
www.blodgett.com
44 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone: (802) 658-6600 Fax: (802)864-0183
PN 39678 Rev AC (9/15)
© 2015 - G.S. Blodgett Corporation
Your Service Agency’s Address:
Model
Serial number
Oven installed by
Installation checked by
11
Installation
Electrical Connections
ELECTRICAL CONNECTION
All Models
NOTE: Electrical connections must be performed by a
qualied installer only.
Before making any electrical connections to these appli-
ances, check that the power supply is adequate for the
voltage, amperage, and phase requirements stated on
the rating name plate mounted on the appliance.
The circuit breaker that is used to provide power to this
appliance must have a minimum of .076(3mm) contact
spacing. The circuit breaker must meet all Local and Na-
tional installation standards.
All appliances must be installed in accordance with Local
or National Electrical codes.
A wiring schematic is located on the inside of the remove-
able side panel.
NOTE: Disconnect the power supply to the appliance
before servicing.
WARNING!!
Improper installation may invalidate your war-
ranty.
Electric Models
A strain relief for the power supply cord is provided. The
installer must supply a cord that meets all Local and Na-
tional installation standards.
Gas Models
U.S. and Canadian Installations
A power cord (115V units only) is supplied with a plug at-
tached. Plug the power cord into the desired receptacle.
This oven model uses a variable frequency inverter drive.
Appliances that use variable frequency inverter drives
produce high frequency noise and require lters and
shielded motor cabling. This causes higher leakage cur-
rent toward Earth Ground. Especially, at the moment of
switching ON this can cause an inadvertent trip of the ap-
pliance’s ground fault interrupter (GFCI). Some GFCIs
are more sensitive than others. Blodgett has qualied
the Pass and Seymour brand, part number 2095, 20 A,
125 VAC, 60 Hz, specication grade GFCI duplex recep-
tacle as being immune to the variable frequency inverter
drive’s noise. Blodgett recommends using this specic
GFCI for this model oven.
WARNING!!
If the supply cord is damaged, it must be re-
placed by a special cord or assembly available
from the manufacturer or its service agent.

Especificaciones del producto

Marca: Blodgett
Categoría: horno
Modelo: BCX-14E
Color del producto: Grijs
Peso.: 3000 g
Ancho: 1290 mm
Profundidad: 135 mm
Altura: 112 mm
Número de lámparas: 1 lampen
tipo-de-lámpara: FD
Lámpara de encendido: 36 W
Código de seguridad internacional (IP): IP65
Certificación: EC, RINA, ENEC
Cantidad por paquete: 1 stuk(s)
Los activos totales: 36 W
clase de protección: I
voltaje-de-entrada-de-CA: 230 V
Frecuencia-de-entrada-de-CA: 50 Hz
Portalámparas: G13

¿Necesitas ayuda?

Si necesitas ayuda con Blodgett BCX-14E haz una pregunta a continuación y otros usuarios te responderán




horno Blodgett Manuales

horno Manuales

Últimos horno Manuales