INSTALLATION MANUAL
Salamander Broiler
PRZSAL
2
BlueStar® Salamander Broiler
MODELS PRZSAL
THIS APPLIANCE WAS DESIGNED FOR EASE OF INSTALLATION AND OPERATION. HOWEVER, WE
RECOMMEND THAT YOU READ ALL SECTIONS OF THIS MANUAL BEFORE YOU BEGIN INSTALLATION.
INSTALLATION MUST BE PERFORMED BY AN APPROVED GAS INSTALLER OR GAS SERVICE TECHNICIAN OR
THE WARRANTY IS VOID. IN THE COMMONWEALTH OF MASSACHUSETTS A LICENSED PLUMBER OR GAS
FITTER CAPABLE OF REVIEWING AND PERFORMING THE MANUFACTURER’S INSTALLATION CHECKLIST
SHOULD INSTALL THIS APPLIANCE. THE INSTALLATION CHECKLIST IS INCLUDED AT THE REAR OF THIS
BOOKLET.
DO NOT REMOVE PERMANENTLY AFFIXED LABELS, WARNINGS OR DATA PLATES FROM YOUR APPLIANCE.
THIS MAY VOID THE MANUFACTURER’S WARRANTY AND/OR HINDER EFFECTIVE SERVICING AND
MAINTENANCE.
THESE INSTRUCTIONS ARE TO REMAIN WITH THE APPLIANCE AND THE CONSUMER IS TO RETAIN THEM FOR
FUTURE REFERENCE.
WARNING: If the information in this manual is not followed exactly, a
fire or explosion may result causing property damage, personal injury
or death.
- Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance
Do not touch or activate any electrical switch
Do not use any phone in your building
Immediately call your gas supplier from a neighbor’s phone.
F ollow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department
- Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
NOTE: WARRANTY SERVICE MUST BE PERFORMED BY AN AUTHORIZED SERVICE AGENT. YOU MAY
REQUEST WARRANTY SERVICE BY CALLING 800-449-8691. YOU MAY ALSO REQUEST SERVICE VIA THE
INTERNET BY SUBMITTING THE SERVICE REQUEST FORM AT WWW.BLUESTARCOOKING.COM
In the Commonwealth of Massachusetts, gas connections must be performed by a licensed plumber or
licensed gas fitter.
Proposition 65 Warning
WARNING: THIS PRODUCT CAN EXPOSE YOU TO CHEMICALS INCLUDING CARBON MONOXIDE WHICH
IS KNOWN TO THE STATE OF CALIFRONIA TO CAUSE BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.
FOR MORE INFORMATION GO TO WWW.P65Warnings.ca.gov
© Copyright 2019 Prizer Painter Stove Works, Inc. All specifications are subject to change wi thout prior notification
Installation and Operation Instructions for
BlueStar® Infrared Salamander Broiler
THIS APPLIANCE MUST BE MOUNTED UNDER AN APPROVED VENTILATION HOOD.
CONTACT A LICENSED GAS CONTRACTOR IN ACCORDANCE WITH THE LOCAL CODES (OR
IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL FUEL GAS CODE, ANSI
Z223.1/NFPA 54) FOR INSTALLATION.
This appliance is not intended to be installed underneath a cabinet.
This appliance must be electrically grounded in accordance with the local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa ).
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½
psi (3.5 kPa ).
The appliance must not be used for space heating purposes.
The cooking area or the exterior top areas are not for storage purposes.
The appliance must be disconnected from the electrical supply before servicing.
The appliance comes set for the type of gas as specified on the rating plate and tag on the unit. If a
different gas type of gas is required, please contact your local authorized gas technician.
Leak testing of the appliance shall be conducted according to the manufacturer’s instructions.
WARNING: ELECTRICAL GROUNDING INSTRUCTIONS
This appliance is equipped with a three-prong grounding plug for your protection against shock hazard
and should be plugged directly into a properly grounded receptacle. Do not cut or remove the grounding
prong from this plug.
All specifications are subject to change without prior notification

Especificaciones del producto

Marca: BlueStar
Categoría: horno
Modelo: PRZSAL24V2
Color del producto: Roestvrijstaal
Ancho: 579 mm
Profundidad: 510 mm
Peso del embalaje: 7000 g
Ancho del embalaje: 620 mm
Empaquetadura en profundidad: 540 mm
Altura del embalaje: 290 mm
Manual de usuario: Ja
Ancho del compartimento de instalación: 559 mm
Profundidad del compartimento de instalación: 495 mm
Fregadero de forma: Rechthoekig
Material del fregadero: Roestvrijstaal
Número de lavabos: 1 kommen
Formar el primer fregadero: Rechthoekig
Dimensiones del primer recipiente (WxL): 500 x 400 mm
Primero viene la profundidad: 200 mm
Kraangat: Ja
Encimera: Nee
Grifo incluido: Nee
Tamaño del fregadero: 3.5 "

¿Necesitas ayuda?

Si necesitas ayuda con BlueStar PRZSAL24V2 haz una pregunta a continuación y otros usuarios te responderán




horno BlueStar Manuales

horno Manuales

Últimos horno Manuales