Broan Elite EI59 Manual de Usario

Lee a continuación 📖 el manual en español para Broan Elite EI59 (32 páginas) en la categoría campana extractora. Esta guía fue útil para 8 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/32
MODEL EI5936SS
Page 1
Chimney Island
Range Hood
READ AND SAVE THESE INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSON(S) OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone the number listed in warranty.
2. servicing Before or cleaning unit, switch power off at service panel
and lock service disconnecting means to prevent power from being
switch on accidentally. When the service disconnecting means
cannot be a locked, securely fasten prominent warning device,
such a as tag, to the service panel.
3. Installation work and electrical be wiring must done by qualified
personnel in accordance codes standards, applicable with all and
including construction fire-rated codes and standards.
4. is combustion Sufficient air needed for proper and exhausting
of gases through the flue (chimney) burning of fuel equipment to
prevent back drafting. Follow the heating equipment manufacturer’s
guideline published and safety standards such as those by the
National Protection Association American Fire (NFPA), and the
Society Refrigeration for Heating, and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. This product may have sharp edges. Be careful to avoid cuts and
abrasions during installation and cleaning.
6. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. only Use metal ductwork.
9. Do not use this unit with any other solid-state speed control device.
10. This unit be must grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers oils that may ignite. Heat
slowly low on or medium settings.
b) Always turn hood ON when cooking at high heat or when flambéing
food Peppercorn (i.e. Crêpes Suzette, Cherries Jubilee, Beef
Flambé).
c) Clean ventilating frequently. fans be Grease should not allowed to
accumulate on fan or filters.
d) Use proper pan size. Always use cookware appropriate for the size
of surface the element.
TO REDUCE THE RISK OF INJURY TO PERSON(S) IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
1. SMOTHER a FLAMES with close-fitting lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
IF DO THE FLAMES NOT GO OUT IMMEDIATELY, EVACUATE
AND CALL THE FIRE DEPARTMENT.
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impeller, keep drywall spray, construction dust, etc. off power unit.
4. Your hood motor has a thermal overload which will automatically
shut off the motor if it becomes overheated. The motor will restart
when it will cool down. If the motor continues to shut off and
restart, the hood serviced. have
5. The bottom of the hood MUST BE LESS than 24” NOT and
recommended at maximum of 36” a above cooktop best for
capture of cooking impurities.
6. Two installers are recommended because of the size of this
hood.
7. To reduce risk of fire and to properly exhaust air, be sure duct to
air outside. Do not exhaust air into spaces within walls or ceilings
or into attics, crawl spaces, or garages.
8. Be careful when installing the decorative flue and hood, they may
have sharp edges.
9. This hood is not intended to a be used as shelf.
10. Please read specification label on product further information for
and requirements.
Installer: Leave this manual
with the homeowner.
Homeowner: Operation and Maintenance
instructions on pages 8 & 9.
WARNING
CAUTION
FOR DOMESTIC COOKING ONLY
WARNING
Register your product online at: www.broan.com
2. NEVER PICK A be UP FLAMING PAN You may burned.
3. DO NOT USE WATER, including wet dishcloths or towels a violent
steam explosion will result.
4. Use extinguisher an ONLY if:
A. You a extinguisher, know you have Class ABC and you
know how operate to it.
B. The is small fire and contained in the it area where started.
C. The department is fire being called.
D. You can fight the fire with your back to an exit.
* Based on published “Kitchen Fire Safety Tips” by NFPA
MODEL EI5936SS
Page 2
FRONT
HOOD
CENTERLINE
HOOD
CENTERLINE
5”
2”
3½”
3½”
HOUSE WIRING
IN THIS AREA
FRONT
HOOD
CENTERLINE
HOOD
CENTERLINE
DUCT
CENTERLINE
OFFSET 1” TO
REAR OF HOOD
8” MINIMUM
8½”
ON CENTER
INSTALL THE DUCTWORK
(Ducted Hoods Only)
1. Decide where the ductwork will run between the hood and
the outside.
2. A straight, short duct run will allow the hood perform most to
efficiently.
3. Long duct runs, elbows and transitions will reduce the
performance of the hood. Use as of them as possible. few
Larger ducting be required best performance with may for
longer duct runs.
4. Install wall cap or roof cap. Connect round metal ductwork to
cap and back the hood location. Use duct tape work towards
to seal the joints between ductwork sections.
PLAN THE INSTALLATION
The minimum hood distance above cooktop MUST BE NOT
LESS than 24”.
A maximum of 36 above cooktop is recommended best for
capture of cooking impurities.
Distances 36 at the installer and users discretion; over are
providing that the ceiling height permits.
INSTALL THE CEILING SUPPORT
1. Construct wood framing that is flush with interior surface of
the ceiling joists.
NOTE
Hood distance above cooktop is: Minimum 24”, Maximum
36”. 9-10 ft. ceilings require Flue Extension Model may
FXNE59SS, depending on installation height (purchase
separately). Discard the upper and lower flues, mounting
frame, and trim strips supplied with your hood and replace
them with Flue Extension Model FXNE59SS.
2. Finish opening to match surrounding ceiling carefully marking
framing location.
INSTALL THE WIRING
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by
providing an escape wire the electric current.for
Position the electrical (house wiring) within the space covered by
the decorative flue and where it will not interfere with the round
duct. Make sure the length of the house wiring is a minimum of 5
feet. It be shortened after hood is installed at correct height may
and electrical connection is made.
ROOF P CA
DECORATIVE
FLUES EAVE
VENT
6” ROUND
ELBOWS
6” ROUND
DUCT
HOOD
24” TO 36” ABOVE
COOKING SUFACE
HOOD
CENTER
LINE
DUCT CENTER LINE
(1” rear of hood centerline)to
MODEL EI5936SS
Page 3
PREPARE THE HOOD
Unpack hood and check contents. You should receive:
1 - Hood Assembly
1 - Glass Canopy
1 - Decorative Flue Assembly
(consisting of 2-upper and 2-lower flue sections)
1 - Hood Frame Assembly
(consisting of upper and lower sections)
2 - Upper Flue Trim Strips
2 - Lower Flue Trim Strips
1 - Aluminum Grease Filter (installed on hood)
4 - 35W MR16 GU10 Halogen Lamps (included on hood)
1 - Parts Bag containing:
6 - Mounting Screws (4mm x 38mm Cross Recessed Head) Pan
3 - Mounting Screws (4mm x 12mm Cross Recessed Pan Head)
12 - Mounting Screws (3mm x 5mm Cross Recessed Head) Pan
4 - Mounting Screws (.188” x .250” Cross Recessed Flat Head)
1 - Suction Cup Tool
3 - Wire Nuts
1 - Installation Manual
6 MOUNTING
SCREWS
(4mm x 50mm
Cross Recessed
Pan Head)
3 MOUNTING
SCREWS
(4mm x 12mm
C dross Recesse
Pan Head)
DECORATIVE
FLUE
ASSEMBLY
4 MOUNTING
SCREWS
(.188” x .250”
Cross Recessed
Flat H )ead
BULB SUCTION
CUP TOOL
HOOD
ASSEMBLY
GLASS
CANOPY
HOOD
FRAME ASSEMBLY
FLUE
TRIM
STRIPS
DECORATIVE
FLUE
ASSEMBLY
12 MOUNTING SCREWS
(3mm x 5mm Cross
Recessed Pan Head)
3 WIRE NUTS

Especificaciones del producto

Marca: Broan
Categoría: campana extractora
Modelo: Elite EI59
Color del producto: Zwart
Pantalla incorporada: Nee
Ancho: 43.3 mm
Profundidad: 17 mm
Altura: 115.9 mm
Amable: Basistoegangscontrolelezer
Código de seguridad internacional (IP): IP65
Indicadores LED: Status
Lector de huellas dactilares: Nee
Señal de advertencia: Ja
Impermeable: Ja
Tipo de procesador: Ja
Frecuencia: 13.56 MHz
Alimentación a través de Ethernet (PoE): Nee
Protocolos soportados: Wiegand(w26, w34)\nMIFARE
PC conectada: Nee
Temperatura de funcionamiento (TT): -20 - 65 °C
Humedad relativa de funcionamiento (VV): 10 - 90 procent
Teclado integrado: Nee
Tipo de autenticación: toegangschip/kaart
Lector de código de acceso: Nee
Acceso al lector de tarjetas/chip: Ja
frecuencia RFID: 13.56 MHz
Soporte RFID: 50 mm

¿Necesitas ayuda?

Si necesitas ayuda con Broan Elite EI59 haz una pregunta a continuación y otros usuarios te responderán




campana extractora Broan Manuales

campana extractora Manuales

Últimos campana extractora Manuales