Quick Reference Guide
English EN
Español ES
Français FR
Nederlands NL
Amhaze Whisper QRG EN
2
About his T
Guide
The Amhaze Whisper Quick Reference Guide (QRG) has basic product
information such as connection, mounting, menu options, and DMX values.
Download the User Manual from for more details.www.chauvetprofessional.com
Disclaimer
The information and specifications contained in this QRG are subject to change
without notice.
Safety Notes
This product is not intended for permanent installation.
Depending on the amount of haze generated, all haze machines may set off
smoke detectors.
Drain the tank before transporting the product.
This product is for indoor use only! (IP20) To prevent risk of fire or shock, do
not expose this product to rain or moisture.
Always disconnect from power before cleaning or replacing the fuse.
Replace the fuse with the same type and rating.
Do not operate this product if the housing, fluid tank, or cables appear
damaged.
In the event of a serious operating problem, stop using immediately.
DO NOT open this product. It contains no user serviceable parts.-
Do not use for space heating purposes.
Never disconnect this product from power by pulling on the cord.
Mount this product in a location with adequate ventilation, at least
20 in (50 cm) from adjacent surfaces.
USE a safety cable when mounting this product overhead.
Do not touch the output nozzle on this product. It is very hot during operation
and it may remain hot for several hours after turning the product off.
Do not leave any flammable material within 50 cm of this product while
operating or connected to power.
Only use Chauvet (PHF) haze fluid or Grignard Pure.
Do not add anything to the fluid.
Do not drink the fluid.
Do not allow the fluid to touch your skin or eyes.
Do not connect this product to a dimmer or rheostat.
Only connect this product to a grounded and protected circuit.
Only use the handles to carry this product.
The maximum ambient temperature is 113 °F (45 °C). Do not operate this
product at higher temperatures.
To eliminate unnecessary wear and improve its lifespan, during periods of
non-use completely disconnect the product from power via breaker or by
unplugging it.
CAUTION: When transferring product from extreme temperature
environments, (e.g. cold truck to warm humid ballroom) condensation may
form on the internal electronics of the product. To avoid causing a failure,
allow product to fully acclimate to the surrounding environment before
connecting it to power.
Contact
Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact
your distributor to request support or return a product. Refer to Contact Us
at the
end of this QRG for contact information.
What Is
Included
Amhaze Whisper
Seetronic Power kon True 1
power cord
Warranty Card
Quick Reference Guide
Amhaze Whisper QRG EN
3
AC Power
This product has a fixed voltage power supply and it can work with an input
voltage of either 120 VAC, 60 Hz or 230 VAC, 50 Hz, depending on the sp
ecific
model.
AC Plug
Connection
Wire (Europe)
Screw Color
AC Live
Brown
Yellow/Brass
AC Neutral
Blue
Silver
AC Ground
Green/Yellow
Green
To eliminate unnecessary wear and improve its lifespan, during periods of
non-
use completely disconnect the product from power via breaker or by
unplugging it.
Replacing The Fuse
1. Disconnect this product from power.
2. Using a Phillips #2 head screwdriver, unscrew the fuse holder cap from the
housing.
3. Remove blown fuse and replace with a good fuse of the same type and rating.
4. Screw the fuse holder cap back in place and reconnect power.
DMX Linking
The DMXAmhaze Whisper will work with a DMX controller using a 3- or 5-pin
serial connection. A DMX Primer is available from
www.chauvetprofessional.com.
DMX Connection
The Amhaze Whisper uses a 3- or 5-pin 2-channel DMX data connection for its
DMX personalit . See the User Manualy for information about connecting
and
configuring the product for DMX operation.
Preparing for
Operation
To prepare the Amhaze Whisper for operation:
1. Open the flight case.
2. Pull out the fluid tank and remove the cap.
3. Verify that the two plastic hoses attached to the inside of the cap are in place
and in good condition.
4. Pour Chauvet PHF -cap. haze fluid or Grignard Pure inside the tank, and re
5. Reinsert the tank.
6. Make sure that the plastic hose that goes from the cap to the hazer is not bent.
7. seconds Plug in power and wait approximately 30 - for warm up to complete.
Only use approved PHF haze fluid or Grignard PureChauvet . Otherwise,
you might not have satisfactory results. In addition, unapproved fluid can
damage the Amhaze Whisper or cause harm to humans or animals.
When storing the product, ALWAYS be sure to store the fluid tank with the
cap up as seen on the
Product Mounting Diagram above before installing the
front cover to avoid tube damage that may cause leakage.

Especificaciones del producto

Marca: Chauvet
Categoría: No categorizado
Modelo: Amhaze Whisper

¿Necesitas ayuda?

Si necesitas ayuda con Chauvet Amhaze Whisper haz una pregunta a continuación y otros usuarios te responderán




No categorizado Chauvet Manuales

No categorizado Manuales

Últimos No categorizado Manuales