Danfoss TP5000 Si Manual de Usario
Danfoss
Termostato
TP5000 Si
Lee a continuación 📖 el manual en español para Danfoss TP5000 Si (2 páginas) en la categoría Termostato. Esta guía fue útil para 5 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/2

Fig.1
TP5000 Si/TP5000 RF Si
User Instructions
Mon-Fri Sat-Sun
Fig.2
Before programming the thermostat press and release the RESET button to restart
the unit. (Fig. 1)
Setting the Clock and Day
The day and time are set in the factory and therefore it will not normally be necessary
to do this on site. Changes between summer and winter time are handled automatically
by the unit.
Accepting the Factory Pre-settings
The TP5000 Si has pre-set times already programmed in, which often suit most people
(see table below).
Note: If set up for 4 events per day, events 3 & 4 are skipped. If set up for 2 events per
day, events 2, 3, 4 & 5 are skipped and the events are re-numbered.
To adjust the factory pre-settings & set your own time and temperature
programmes
For Days 1-5 (weekdays)
a) Press PROG (Fig. 2) until the 1st pre-set time and temperature (Event 1 Days 1,2,3,4,5)
(Fig. 3).
b) Use + or – buttons (Fig. 4) to adjust the TIME (press and hold to change in 10 min
increments).
c) Use Λ or V buttons (Fig. 5) to adjust the TEMPERATURE.
d) Press PROG (Fig. 2) to move to next preset time & temp (Event 2) (Fig. 6).
e) Repeat steps b, c & d for programming Events 3, 4, 5 & 6.
For Days 6-7 (weekends)
Press •PROG (Fig. 2) to show 1st pre-set time and temperature (Event 1 Days 6-7)
(Fig. 7).
Repeat steps b, c and d above to programme time and temperature events for •
the weekend.
Returning to RUN mode
Press PROG (Fig. 2) – the colon in the LCD display will start to flash (Fig. 8).
Fig.5
Fig.4
Fig.6
Fig.7
Fig.8
Event Time Temp. °C
1 06:30 20
2 08:30 15
3 11:30 20
4 13:30 15
5 16:30 21
6 22:30 15
Event Time Temp. °C
1 07:30 20
2 09:30 20
3 11:30 20
4 13:30 20
5 16:30 20
6 22:30 15
RESET
Fig.3
Complete Shut off - Summer time
Press Λ and V together to enter thermostat mode. A frost protection symbol (snowflake in a
shield) will appear in the display . Press the down arrow ∨ once, OFF will appear in the display.
To return to automatic programming press both ∧ and ∨ together.

Danfoss Randall Ltd
Ampthill Road
Bedford, MK42 9ER
Tel: 0845 1217 400
Fax: 0845 1217 515
Email: danfossrandall@danfoss.com
Website: www.danfoss-randall.co.uk
Fig.10
Fig.11
Selection of time
or actual room
temperature in main
LCD display
Temporary
override of
programmed
temperature
press
together
Frost
Protection
Fig.9
Fig.12
Temporary User Overrides
The TP5000 has several useful overrides which can be selected without affecting the
thermostat programming.
• Selection of time or actual room temperature in main LCD display – press +
and – together to change between settings (Fig. 9).
• Temporary override of programmed temperature – press Λ or V until required
temperature is displayed (override will automatically cancel at beginning of next
programmed event) (Fig. 10).
• Frost Protection – a constant low temperature can be selected whilst away from
home - press Λ and V together (Fig.11). Then use Λ or V to select the required
temperature. To return to automatic programming press Λ and V together again.
Battery Replacement
• Alowbattery symbol will flash in the LCD display (Fig. 12)
You have 15 days to replace the battery before the unit will switch off. •
Remove old batteries and insert new ones. All settings including time are •
maintained.
Press and release the •RESET button to restart the unit. (Fig. 1)
NB. If the display ever goes blank during normal operation, the batteries will need
to be renewed with high quality alkaline cells. The reset button should be pressed
to restart the unit. All times, dates and events will be retained and need not be re-
programmed.
If the property is owned by a landlord he may, for gas safety reasons, have instructed the installer
to set the service interval timer.
If set a visual and audible warning will alert you that the boiler will need servicing within the next
28 days. This warning is repeated each day at noon. (Fig. 15)
If the boiler is not serviced within 28 days the daily audible warning will sound continuously and
can only be cancelled each day by pressing any button on the unit.
In addition, all overrides and programming buttons will be disabled and the heating and hot water
will only operate for 15 minutes in each programmed hour.
As this is a gas safety feature only an installer can reset the service interval timer. This will be done
as part of the boiler service as part of the boiler service.
Service Interval Timer
Fig. 15
Commissioning Instructions
If the thermostat and the receiver have been supplied together in a combined pack, the
units have been paired in the factory and no commissioning is required (RX1 only).
To tune the RX receiver to the frequency of the thermostat signal, follow steps 1-5 below.
Step 1
TP5000-RF Si - Reset the unit by pressing the recessed reset button.
Step 2
Press and hold V and + buttons (fig. 13) for 3 seconds (TP5000 RF Si now transmits unique signal
continuously for 3 minutes).
Step 3
RX1 - Press and hold buttons PROG and CH1 for 3 seconds until green light flashes once.
(Fig. 14)
Step 4 (Fig.14)
RX2 (if applicable)
Stat 1 - perform steps 1-3 and 5.
Stat 2 -perform steps 1-2 and then press PROG and CH2 on RX2.
RX3 (if applicable)
Stat 1 - perform steps 1-3 and 5.
Stat 2 - perform steps 1-2 and then press PROG and CH2 on RX3 then step 5.
Stat 3 - perform steps 1-2 and then press PROG and CH3 on RX3.
Step 5
TP5000Si-RF - Press V or Λ to select temperature - the unit will revert back to operating mode.
IMPORTANT RF Models only
To ensure that the factory programmes are set and the micro-computer is operating correctly
it is essential that you press and hold the RESET button before you begin any commissioning or
programming.
Fig.13
Fig.14
Especificaciones del producto
Marca: | Danfoss |
Categoría: | Termostato |
Modelo: | TP5000 Si |
¿Necesitas ayuda?
Si necesitas ayuda con Danfoss TP5000 Si haz una pregunta a continuación y otros usuarios te responderán
Termostato Danfoss Manuales

27 Octubre 2024

6 Octubre 2024

5 Octubre 2024

23 Septiembre 2024

17 Septiembre 2024

9 Septiembre 2024

6 Septiembre 2024

4 Septiembre 2024

1 Septiembre 2024

Danfoss Ally - Radiator Thermostat Thermostaat Manual de Usario
1 Septiembre 2024Termostato Manuales
- Termostato ATAG
- Termostato Bosch
- Termostato AEG
- Termostato Panasonic
- Termostato Honeywell
- Termostato Junkers
- Termostato Nefit
- Termostato Remeha
- Termostato Siemens
- Termostato Vaillant
- Termostato Ambiano
- Termostato Amfra
- Termostato Google
- Termostato GE
- Termostato Renkforce
- Termostato Itho
- Termostato De Dietrich
- Termostato TP Link
- Termostato Elro
- Termostato EMOS
- Termostato Truma
- Termostato Intergas
- Termostato Energenie
- Termostato Schneider
- Termostato Hama
- Termostato Fenix
- Termostato Theben
- Termostato AVM
- Termostato Elektrobock
- Termostato Devi
- Termostato Stiebel Eltron
- Termostato Buderus
- Termostato Velleman
- Termostato Dimplex
- Termostato Emerson
- Termostato Vemer
- Termostato Profile
- Termostato Magnum
- Termostato Horstmann
- Termostato Salus
- Termostato Tylö
- Termostato Somfy
- Termostato Grohe
- Termostato Corberó
- Termostato Oventrop
- Termostato King
- Termostato Technoline
- Termostato Devolo
- Termostato Arnold Rak
- Termostato Heatmiser
- Termostato Viessmann
- Termostato Carrier
- Termostato Nest
- Termostato Itho-Daalderop
- Termostato Hive
- Termostato Saunier Duval
- Termostato Netatmo
- Termostato Seitron
- Termostato Hager
- Termostato Sygonix
- Termostato TFA
- Termostato Tado
- Termostato Hunter
- Termostato Plieger
- Termostato Busch-Jaeger
- Termostato Zehnder
- Termostato Bulex
- Termostato UPM
- Termostato Optima
- Termostato AWB
- Termostato Finder
- Termostato Xavax
- Termostato Fantini Cosmi
- Termostato Delta Dore
- Termostato Orbis
- Termostato Boneco
- Termostato EBERLE
- Termostato Grasslin
- Termostato Gira
- Termostato Jung
- Termostato Basetech
- Termostato Wolf
- Termostato HQ
- Termostato Max
- Termostato Eneco
- Termostato Frico
- Termostato Vasco
- Termostato Radson
- Termostato Nobo
- Termostato Baxi
- Termostato Fibaro
- Termostato Nexa
- Termostato EQ3
- Termostato Homematic IP
- Termostato Go Green
- Termostato Weishaupt
- Termostato REMKO
- Termostato ICY
- Termostato HomeMatic
- Termostato Computherm
- Termostato Avidsen
- Termostato SPC
- Termostato Crestron
- Termostato ORNO
- Termostato Berker
- Termostato Drayton
- Termostato Westfalia
- Termostato Heatit
- Termostato 2Heat
- Termostato Bryant
- Termostato Watts
- Termostato Eqiva
- Termostato Etherma
- Termostato Veria
- Termostato Emmeti
- Termostato Eurotronic
- Termostato Oregon Scientific
- Termostato Muller
- Termostato Worcester-Bosch
- Termostato Econo-Heat
- Termostato VDH
- Termostato Vimar
- Termostato PECO
- Termostato IR-V
- Termostato H-Tronic
- Termostato EasyTemp
- Termostato Elgato
- Termostato Intertechno
- Termostato Schwaiger
- Termostato Helios (Amfra)
- Termostato EQ-3
- Termostato Tru Components
- Termostato Emko
- Termostato Easy Timer
- Termostato Z-Wave
- Termostato Hugo Muller
- Termostato IMIT
- Termostato Innogy
- Termostato Wallair
- Termostato Maico
- Termostato Levica
- Termostato HomePilot
- Termostato Ouellet
- Termostato Techno Line
- Termostato THERMAFLEX
- Termostato Wachendorff
- Termostato Yokis
- Termostato ChiliTec
- Termostato Eliwell
- Termostato Plugwise
- Termostato Johnson Control
- Termostato Webasto
- Termostato Drayton Erie
- Termostato OJ ELECTRONICS
- Termostato Tellur
- Termostato RWE
- Termostato Lowes
- Termostato Jumo
- Termostato Warmup
- Termostato Qubino
- Termostato STI
- Termostato ELKO
- Termostato TrickleStar
- Termostato Gewiss
- Termostato Sinustec
- Termostato Rose LM
- Termostato Otio
- Termostato MundoControl
- Termostato Enda
- Termostato Bearware
- Termostato GENERAL Life
- Termostato Oreg
Últimos Termostato Manuales

27 Octubre 2024

26 Octubre 2024

26 Octubre 2024

26 Octubre 2024

26 Octubre 2024

26 Octubre 2024

26 Octubre 2024

26 Octubre 2024

26 Octubre 2024

26 Octubre 2024