Danfoss TP5001M Manual de Usario

Lee a continuación 📖 el manual en español para Danfoss TP5001M (104 páginas) en la categoría Termostato. Esta guía fue útil para 9 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/104
User Guide
Danfoss Heating
MAKING MODERN LIVING POSSIBLE
TP5001 Range
Electronic Programmable Room Thermostat
2
An introduction to your programmable room thermostat
Your programmable room thermostat allows you to programme
diff erent temperatures at diff erent time periods. You can programme
one set of times and temperatures for week days with a diff erent set of
temperatures for weekend days, this is referred to as 5/2 day operation.
The thermostat can also be set up by your installer to provide one set
of times and temperatures that are repeated each day of the week. This
is referred to as 24 hour operation.
The thermostat can also be set by you to provide two diff erent
programming blocks which can then be assigned to any day of the
week, this is referred to as A/B programme operation.
All thermostats can be set by your installer to provide up 2, 4 or 6 time
and temperature settings each day.
All thermostats feature useful overrides, including a programmable
frost setting.
Your thermostat has some advanced features which the installer will
set-up if they are required. There are also a number of advanced features
which can be set up by you. These advanced settings alter the way that
your thermostat operates, some also aff ect the programming functions
and the user overrides. Please read the User Advanced Programming
instructions before programming the unit (see page 10).
Preset programmes
Your TP5001 comes ready programmed with a set of operating times and
temperatures which suit most people. Please remember that some of the
options available will depend on how the installer has set up the unit.
User Instructions
User Instructions
GB
Weekdays (Mon-Fri) Weekend (Sat-Sun)
Event Time Temp. °C Event Time Temp. °C
1 06:30 20 1 07:30 20
2 08:30 15 2 09:30 20
3 11:30 20 3 11:30 20
4 13:30 15 4 13:30 20
5 16:30 21 5 16:30 21
6 22:30 15 6 22:30 15
Note: these are also times for Block
A programmes
Note: these are also times for Block “B”
programmes
3
Note: If set up for 4 events per day, events 3 & 4 are skipped. If set up
for 2 events per day, events 2, 3, 4 & 5 are skipped. In both cases the
events are re-numbered.
Before you start
Open the fl ap on the front of the programmer and
press the RESET button with a non-metallic object
until the display goes blank. This will ensure that
the factory programmes are set and that the micro-
computer in the product is operating correctly.
Customising the display
For the sake of clarity, the instructions assume that the display setting
uses a 24 hour clock, °C and that days of the week are numbered 1-7,
(where 1 is Monday). All of these settings can be personalised after the
thermostat has been programmed, see pages 8 and 9.
Setting the correct date and time
Your TP5001 incorporates a real time clock with calendar function that
automatically changes time in both Spring and Autumn. The time and
date is set in the factory for the CET time zone, and does not normally
require adjustment. If you live in another time zone refer to Time zone
off set on page 11. However, should it be found necessary to adjust
time or date for any other reason refer to the following instructions.
User Instructions
GB
RESET
Setting the date
Press and hold Λ and PROG for 3 seconds, to
display date in dd/mm/yy format.

Especificaciones del producto

Marca: Danfoss
Categoría: Termostato
Modelo: TP5001M

¿Necesitas ayuda?

Si necesitas ayuda con Danfoss TP5001M haz una pregunta a continuación y otros usuarios te responderán




Termostato Danfoss Manuales

Termostato Manuales

Últimos Termostato Manuales