Installation alternatives
Dowelled on finished
floor (standard)
With mounting plate
on subfloor level
Cast-in in finished
floor level
Ø 5-1/2"
Ø 140
Ø 9-7/16"
Ø 240
5/16"
(8)
Ø 5-1/2"
Ø 140
9-13/16"
(250)
X
"Ø 5-1/2
Ø 140
Ø 4-3/4"
Ø 120
5-15/16"
(150)
Entrance systems
HSD-E03
Half-height swing doors
Entrance systems
Standard units HSD-E03
Construction
Tubular column Made of AISI 304 stainless steel, Ø 5-1/2"(Ø 140)
Barrier element Full-height glass element, 3/8" (10) TSG with straight handle bar.
Leaf radius 35-7/16" (900)
Leaf upper edge 35-7/16 (900)
Locking system Drive and toothed holding brake installed in tubular column.
Finish Stainless steel satin finish.
Function Type 2: Power-assisted motion, servo positioning drive/electrically
controlled in 2 directions.
90° opening in entrance and exit directions.
Electrical equipment Control unit and power supply unit in an external switch cabinet
H = 11-1/8" (283) / W = 6-5/8” (168) / D = 4-1/2” (115).
Power supply 100–240 VAC 50/60 Hz.
Installation Dowelled on finished floor level, FFL.
Not suitable for outdoor installation.
Protection classes Housing IP43, components conducting supply voltage IP54.
Subject to change without notice
Note
Dimensions shown as inches
followed by millimeters; for
example, 1" (25).
2
dormakaba HSD-E03 half-height swing door
HSD-E03 options
Construction
Glass element, slanted.
Glass element, half-height.
Passage width 39-3/8" (1000).
Passage width:
min. 25-9/16” (650), max. 39-5/16” (999).
Special leaf width: minimum 25-9/16” (650).
Special height:
Door leaf raised to max. 47-1/4” (1200), 55-1/8” (1400).
Function
Master for linking two units as a double swing door.
Electrical equipment
Operating panels and frames or surface mount housing.
Additional circuit boards for expanding existing inputs and outputs.
Distribution board (connection of max. 4 OPL05 possible).
Installation
Mounting plate with variable substructure, measure X = 3-1/8” – 7-1/16” (80 – 180).
Cast-in with floor element.
EO 12.18 07000508-3
dormakaba USA Inc.
Dorma Drive, Drawer AC
Reamstown, PA 17567
844.SPECNOW
www.dormakaba.us
Ø 5-1/2"
Ø 140
35-7/16"
(900)
1-9/16"
40
35-7/16" (900)
Elevation drawing
HSD-E03

Especificaciones del producto

Marca: Dormakaba
Categoría: No categorizado
Modelo: HSD-E03

¿Necesitas ayuda?

Si necesitas ayuda con Dormakaba HSD-E03 haz una pregunta a continuación y otros usuarios te responderán




No categorizado Dormakaba Manuales

No categorizado Manuales

Últimos No categorizado Manuales