INSTALLATION
RCI 4/7 SERIES
ELECTRIC STRIKES
© 2019 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.comIS47A
PCN18041
R03-19TG
A 1-1/4 1.250 31.75
B 4-7/8 4.875 123.83
C 3-3/8 3.375 85.73
D 7/8 .875 22.23
E 3/8 .375 9.53
F 1/8* .125* 3.18*
G 1-11/16 1.688 42.86
X
R 5/32 .156 3.97
K 4-1/8 4.125 104.78
M 12-24
C
RCI 7104, 7304 Aluminum Frames, 1-1/2D
RCI 4104, 4304 Aluminum Frames, 1-1/2D
Any modular or A41 A43 A71, , A73
with B4704 faceplate
MEASUREMENT
FRACTIONAL
INCHES
DECIMAL
INCHES
METRIC
mm
Vertical Centerline
of Door**
RCI 7105, 7305 Aluminum & Wood Frames, 1-1/2” D
RCI 4105, 4305 Aluminum & Wood Frames, 1-1/2” D
Any modular or A41 A43 A71, , A73
with B4705 faceplate
MEASUREMENT
FRACTIONAL
INCHES
DECIMAL
INCHES
METRIC
mm
A 1-1/8 1.125 28.58
B 5-7/8 5.875 149.23
C 3-3/8 3.375 85.73
D 7/8 .875 22.23
E 1/4 .250 6.35
F 1/8* .125* 3.18*
G 1-11/16 1.687 42.86
X
R 5/32 .156 3.97
K 5-3/8 5.375 136.53
M 12-24
1. Determine the vertical centerline of the door lock face and
the horizontal centerline of the latch.
IMPORTANT: When determining the horizontal centerline
observe the following:
FOR MORTISE LOCKS: Align the angled ramps of the lip
bracket with the deadlock trigger of the mortise latch.
FOR CYLINDRICAL LOCKS: Align the center of the latch with
the center of the strike opening.**
2. Transfer both the horizontal and vertical centerlines to the
doorframe.**
3. Prepare the doorframe for cutting as per the appropriate
drawing.
4. If required, install “no weld” mounting brackets as per the
instructions on page 3.
5. Attach the strike insert (coil unit or “motor”) to the
lip bracket with the small machine screws provided.
(M4 x 9.5mm)
6. Attach the strike faceplate to the lip bracket with machine
screws (M4 x 9.5mm) provided. (It may be desirable to leave
these screws slightly loose to facilitate insertion into the
doorframe.)
7. Connect the incoming wiring from the power supply to the
terminal screws on the strike insert. RCI door strikes are
not polarity sensitive although be certain to observe proper
polarity if a suppression diode is required for access control
applications.
8. Install the door strike in the doorframe using the screws
provided.
Instructions
NOTE: Specifications subject to change without notice.
* Dimension F is measured from face of mounting tab to face of frame.
** Dimension X on the drawing is determined by the vertical centerline of the door. If the latch incorporates a deadlocking pin additional steps will be
necessary to ensure proper operation of the deadlocking pin. Measure the thickness of the deadlocking pin and add this thickness to Dimension X to
relocate the vertical centerline an appropriate distance on the frame.
For wood frame door installations, substitute #12 wood screws for dimension M.
Vertical Centerline
of Door**
© 2019 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.com
C
RCI 7107, 7307 Aluminum & Wood Frames, 1-1/2” D
RCI 4107, 4307 Aluminum Frames, 1-1/2D
Any modular or with faceplateA41 A43 A71, , A73 B4707
RCI 7108, 7308 Aluminum & Wood Frames, 1-1/2” D
RCI 4108, 4308 Aluminum & Wood Frames, 1-1/2” D
Any modular or with faceplateA41 A43 A71, , A73 B4708
C
RCI 7114, 7314 Hollow Metal Frames, 1-1/2D
RCI 4114, 4314 Hollow Metal Frames, 1-1/2D
Any modular or with faceplateA41 A43 A71, , A73 B4714
C
G
G
K
B
A
D
X
E
C
L
C
RCI 7119, 7319 Hollow Metal & Wood Frames, 1-1/2” D
RCI 4119, 4319 Hollow Metal & Wood Frames, 1-1/2” D
Not available in modular program
MEASUREMENT
FRACTIONAL
INCHES
DECIMAL
INCHES
METRIC
mm
A 1-3/8 1.375 34.93
B 9 9.0 228.60
C 3-3/4 3.75 95.25
D 1-1/2 1.50 38.10
E 5/16 .312 7.94
F 1/8* .125* 3.18*
G 1-7/8 1.875 47.63
X
K 8-3/8 8.375 212.73
M 12-24
Vertical Centerline
of Door**
A 1-1/4 1.250 31.75
B 6-7/8 6.875 174.64
C 3-3/8 3.375 85.73
D 7/8 .875 22.23
E 3/8 .375 9.53
F 1/8* .125* 3.18*
G 1-11/16 1.687 42.86
X
R 5/32 .156 3.97
K 6-1/8 6.125 155.58
M 12-24
MEASUREMENT
FRACTIONAL
INCHES
DECIMAL
INCHES
METRIC
mm
MEASUREMENT
FRACTIONAL
INCHES
DECIMAL
INCHES
METRIC
mm
A 1-1/4 1.250 31.75
B 4-7/8 4.875 123.83
C 3-3/8 3.375 85.73
D 7/8 .875 22.23
E 3/8 .375 9.53
F 1/8* .125* 3.18*
G 1-11/16 1.687 42.86
X
K 4-1/8 4.125 104.78
M 12-24
Vertical Centerline
of Door**
Vertical Centerline
of Door**
MEASUREMENT
FRACTIONAL
INCHES
DECIMAL
INCHES
METRIC
mm
A 1-7/16 1.438 36.51
B 7-15/16 7.938 201.61
C 3-3/8 3.375 85.73
D 7/8 .875 22.23
E 1/4 .250 6.35
F 1/8* .125* 3.18*
G 1-11/16 1.687 42.86
X
R 5/32 .156 3.97
K 7-7/16 7.438 188.91
M 12-24
Vertical Centerline
of Door**
NOTE: Specifications subject to change without notice.
* Dimension F is measured from face of mounting tab to face of frame.
** Dimension X on the drawing is determined by the vertical centerline of the door. If the latch incorporates a deadlocking pin additional steps will be
necessary to ensure proper operation of the deadlocking pin. Measure the thickness of the deadlocking pin and add this thickness to Dimension X to
relocate the vertical centerline an appropriate distance on the frame.
For wood frame door installations, substitute #12 wood screws for dimension M.
When installing an electric strike on an inactive door of a set of double doors, it can be treated the same as a frame installation in most situations.
For more information contact the Technical Service Department.
© 2019 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.com
Mounting Tab Kit Instructions
The mounting tab kit is for use with aluminum and steel frames
that do not have factory installed mounting tabs for electric
strike installation.
1. Prepare the frame as shown in the approximate drawing.
Fasten the mounting tab to the faceplate of the strike,
selecting the appropriate shims for the installation.
2. Using the assembled strike and tabs as a template, place
against the frame and mark the mounting hole locations that
suit best. Remove and drill two 3/16” holes in frame for each
mounting tab and countersink the frame.
3. Remove the tabs from the faceplate and install in the frame
using the 12-24 x 3/8” machine screws supplied. Tabs are
zinc plated and drilled and tapped for this purpose.
4. Make final electrical connections per wiring instructions
and mount strike to the tabs with the 12-24 x 3/8” machine
screws.
Trim Plate Instructions
1. Position the Trim Plate on the frame cut-out to verify fit and
coverage.
2. Adjust cut-out if required.
3. Bend the four tabs to hold the Trim Plate onto the frame.
4. For a tighter fit, pre-bend the two long flange tabs before
sliding onto the frame where space allows.
5. Secure the strike to the frame as per strike installation
instructions.