Network Analyzer
User Manual
MPR-1X
Series
www.entes.eu
2
SAFETY AND WARNING .............................................................................. 3
Attention 3 ....................................................................................................
Safety 3 .......................................................................................................
OPERATING CONDITIONS 4 ..........................................................................
INTRODUCTION 5 ...........................................................................................
General Specications .............................................................................. 5
Applications .............................................................................................. 6
MPR-1 Product Family 7 ..............................................................................
Appearance and Interface 7 ........................................................................
Terminal Structures ................................................................................... 8
Structure of the MPR-14S Terminal: 8 .........................................................
Structure of the MPR-15S-22 Terminal: 9 ....................................................
Structure of the MPR-16S-21 Terminal: 10 ..................................................
Structure of the MPR-17S-23 Terminal: ...................................................11
CONNECTION TYPES ................................................................................ 12
3P4W (Three-Phase Four-Wire) Connection .......................................... 12
3P3W (Three-Phase Three-Wire) Connection ........................................ 13
ARON Connection 13 ..................................................................................
3P4W BLN
(Three-Phase Four-Wire Balanced)
Connection 14 ..................
3P3W BLN (Three-Phase Three-Wire Balanced) Connection ................ 14
Communication Line Termination Resistance ......................................... 15
Device Communication Settings ............................................................. 16
TECHNICAL INFORMATION AND ATTACHMENTS ................................... 17
Technical Information 17 ..............................................................................
IEC 61557-12 Properties ........................................................................ 18
Compliance with the Standards .............................................................. 19
Index
3
SAFETY AND WARNING
Attention
If the following instructions are not carefully followed, the circumstances which can cause
death and serious injuries might happen.
The installation of the device must be performed by the qualied and trained personnel.
Please, cut the whole power while installing the device. Please, use a suitable circuit
breaker on the installation terminal.
You must connect the power lead-ins of the device by using a current transformer. Do not
apply direct current connection.
Never, remove the front panel while the device is connected to the mains.
Never, clean the device by any solvent or similar material. Only use dry cloth for cleaning it.
Before, turning on the device, make sure that the connections are correct.
Please, contact your authorized dealer in case of any problem with your device.
The device is only for interior panel type assembly. Only the front panel of the device
should be accessible from the switchboard.
The fuse to be used must be CATIII and F type and the current limit value should be 1A
Current measurement inputs must be connected with auxiliary current
transformers which have reinforced insulation.
The power meter shall not be used for primary protection or applications where
its failure can cause harm or death.
Please de-energize the device before replacing RTC backup battery. It must be Li/MnO2
battery.
The manufacturer rm cannot be held responsible in any way for any circumstance which might
arise if the mentioned precautions are not implemented.
Safety
Please, read the entire operating manual before using the device.
Connect a button or a circuit breaker between the mains and the supply inputs of the device.
The button or circuit breaker to be connected should be close to the device.
It should be labeled that the button or circuit breaker to be connected will be used for
separating the device from the mains.
This device is used for analyzing the electricity mains and it must not be used for main
protection function.
Guarantee
The guarantee term of the device is 2 (two) years. In case of any problem, the repair of
the device must be done only by the manufacturer rm; otherwise, the guarantee of the
device becomes invalid.

Especificaciones del producto

Marca: Entes
Categoría: No categorizado
Modelo: MPR-17S-23

¿Necesitas ayuda?

Si necesitas ayuda con Entes MPR-17S-23 haz una pregunta a continuación y otros usuarios te responderán




No categorizado Entes Manuales

No categorizado Manuales

Últimos No categorizado Manuales