Friedrich Chill Premier Inverter CCV08A10A Manual de Usario

Friedrich aire acondicionado Chill Premier Inverter CCV08A10A

Lee a continuación 📖 el manual en español para Friedrich Chill Premier Inverter CCV08A10A (15 páginas) en la categoría aire acondicionado. Esta guía fue útil para 7 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/15
Installation and Operation Manual
THE E XP ERTS IN RO OM AI R CONDI T IONIN G
93011012_01
2
US
C
TABLE OF CONTENTS
A. IMPORTANT SAFETY AND GENERAL INFORMATION .................3
A.1 Introduction 3 .............................................................................
A.2 Safety Warnings 3 ......................................................................
A.3 Warning For Using R32 Refrigerant 5 .....................................
A.3 Importance of a Quality Installation 8 .....................................
A.4 Product Inspection / Packing List 8 ........................................
B. SPECIFICATIONS .................................................................................9
B.1 Dimensions 9 ..............................................................................
C.1 Pre-Installation Checkpoints ...............................................10
C.2 Tools Required ......................................................................11
C.3. Choosing a Location 11 .............................................................
C.4 Window Installation 12 ..............................................................
E. ELECTRICAL ........................................................................................17
E.1 Electrical Safety Information 17 .........................................
J. STARTUP AND OPERATION ..............................................................18
J.1 Control Panel Operation 18 .......................................................
J.2 Remote Control Operation 22 ...................................................
J.5 Start-up...................................................................................23
L. WIFI .......................................................................................................23
M. TROUBLESHOOTING .........................................................................24
M.1. Troubleshooting Tips 24 ......................................................
R . INFORMATION FOR THE OWNER ...................................................26
R.1 Maintenance ..............................................................................26
R.2 Warranty 27 ................................................................................
CAUTION: Do Not Operate Equipment During Active Stages Of Construction
To ensure proper operation, Friedrich requires that all equipment is not operated during active construction phases. This includes active
stages of completing framing, drywalling, spackling, sanding, painting, flooring, and moulding in the equipment’s designated conditioning
space. The use of this equipment during construction could result in premature failure of the components and/or system and is in violation of
our standard warranty guidelines. The operation of newly installed equipment during construction will accelerate the commencement and/or
termination of the warranty period.
Register your Air Conditioner
Model information can be found on the name plate.
Please complete and mail the owner registration card furnished
with this product, or register online at www.friedrich.com.
For your future convenience, record the model information .
Model Number ________________________
Serial Number ________________________
A. IMPORTANT SAFE
4
A. IMPORTANT SAFETY AND GENERAL INFORMATION
Read All Instructions and Cautionary Markings Before Operation
and Installation to prevent death or injury to the user, other people,
or property damage, the following instructions must be followed.
Incorrect operation due to ignoring of instructions may cause death,
harm or damage.
This symbol indicates the possibility of a WARNING:
hazard to personnel.
This symbol indicates the possibility of CAUTION:
property damage or serious consequences.
WARNING:
1. Installation must be performed according to the installation
instructions. Improper installation can cause water leakage, electrical
shock, or fire.
2. Use only the included accessories and parts, and specified tools for
the installation. Using nonstandard parts can cause water leakage,
electrical shock, fire, and injury or property damage.
3. Make sure that the outlet you are using is grounded and has the
appropriate voltage. The power cord is equipped with a three-prong
grounding plug to protect against shock. Voltage information can be
found on the nameplate of the appliance.
4. Your appliance must be used in a properly grounded wall
receptacle. If the wall receptacle you intend to use is not adequately
grounded or protected by a time delay fuse or circuit breaker (the
fuse or circuit breaker needed is determined by the maximum current
of the appliance. The maximum current is indicated on the model
nameplate located on the appliance, have a qualified electrician install
the proper receptacle.
5. Install the appliance on a flat, sturdy surface. Failure to do so could
result in damage or excessive noise and vibration.
6. The appliance must be kept free from obstruction to ensure proper
function and to mitigate safety hazards.
7. The unit should not be in contact with any equipment that will
transmit vibration to the unit. Any excessive vibration or pulsation to
the unit could result in damage to the refrigerant tubing.
8. Do not modify the length of the power cord or use an extension
cord to power the appliance.
9. Do not share a single outlet with other electrical appliances.
Improper power supply can cause fire or electrical shock.
10. Do not install your air conditioner in a wet room such as a
bathroom or laundry room. Too much exposure to water can cause
electrical components to short circuit.
11. Do not install the appliance in a location that may be exposed to
combustible gas, as this could cause fire.
12. Do not operate the appliance if it has been dropped or damaged.
13. Do not touch the appliance with wet or damp hands or when
barefoot.
14. If the air conditioner is knocked over during use, turn off the
appliance and unplug it from the main power supply immediately.
Visually inspect the appliance to ensure there is no damage. If you
suspect the appliance has been damaged, contact a technician or
customer service for assistance.
15. In a thunderstorm, the power must be cut off to avoid damage
to the machine due to lightning. Your air conditioner should be used
in such a way that it is protected from moisture. e.g. condensation,
splashed water, etc. Do not place or store your air conditioner
where it can fall or be pulled into water or any other liquid. Unplug
immediately if it occurs.
16. All wiring must be performed strictly in accordance with the
wiring diagram located inside of the appliance.
17. The appliance’s circuit board(PCB) is designed with a fuse to
provide overcurrent protection. The specifications of the fuse are
printed on the circuit board, such as: T 3.15A/250V, etc.
18. After proper installation, condensate will not overflow during
normal use. If the fan hits the built-up water and the sound annoys
you, please remove the cap located at the back of the air conditioner
to drain the water away.
CAUTION:
1. This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities or
lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to ensure
that they do not play with the appliance. Children must be supervised
around the appliance at all times.
2. If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order
to avoid a hazard.
3. Prior to cleaning or other maintenance, the appliance must be
disconnected from the supply mains.
4. Never use this appliance if it is not working properly, or if it has
been dropped or damaged.
5. Do not run cord under carpeting. Do not cover cord with throw rugs,
runners, or similar coverings. Do not route cord under furniture or
appliances. Arrange cord away from traffic area and where it will not
be tripped over.
6. Do not operate with a damaged cord, plug, power fuse or circuit
breaker. Discard the appliance or return to an authorized service
facility for examination and/or repair.
7. To reduce the risk of fire or electric shock, do not use this fan with
any solid-state speed control device.
8. The appliance shall be installed in accordance with national wiring
regulations.
9. Contact the authorized service technician for repair or maintenance
of this appliance.
10. Contact the authorized installer for installation of this appliance.
11. Do not cover or obstruct the inlet or outlet grilles.
12. Do not use this product for functions other than those described in
this instruction manual.
13. Before cleaning, turn off the power and unplug the appliance.
14 .Disconnect the power if strange sounds, smell, or smoke comes
from it.
15. Do not press the buttons on the control panel with anything other
than your fingers.
16. Do not operate or stop the appliance by inserting or pulling out the
power cord plug.
17. Do not use hazardous chemicals to clean or come into contact with
the appliance.
18. Do not use the appliance in the presence of flammable substances
or vapor such as alcohol, insecticides, petrol,etc.
19. Always contact a qualified person to carry out repairs. If the power
supply cord is damaged, it must be replaced with a new power supply
cord obtained from the product manufacturer and not repaired.
20. Hold the plug by the head of the power plug when taking it out.
21. Turn off the product when not in use.
A. IMPORTANT SAFE

Especificaciones del producto

Marca: Friedrich
Categoría: aire acondicionado
Modelo: Chill Premier Inverter CCV08A10A

¿Necesitas ayuda?

Si necesitas ayuda con Friedrich Chill Premier Inverter CCV08A10A haz una pregunta a continuación y otros usuarios te responderán




aire acondicionado Friedrich Manuales

aire acondicionado Manuales

Últimos aire acondicionado Manuales