Friedrich ZoneAire PH14B Manual de Usario

Friedrich aire acondicionado ZoneAire PH14B

Lee a continuación 📖 el manual en español para Friedrich ZoneAire PH14B (10 páginas) en la categoría aire acondicionado. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/10
FRIEDRICH
Service
&
Parts
Manual
- 2012
PortableAirConditioner
Models
PH14B
Portable
Air
Conditioner-2012 Svc-Parts
(01/2012)
Important points
on
service
,
and flow
chart
for
inspecting
and
repairing
the unit
...............2
Troubleshooting .............................................2
Appearance
and
unit
dimensional...................3
Operatio
n
....................................................
4-5
Technica
l
specifications..............................
6
Refrigerator system
and
schematic
wiring
diagrams ........................................................
7
Exploded
view and Parts
Lists
....................8
-10
98081402
00
Only a qualified professional should perform any repair service(s).
When replacing any electrical components they should be OEM factory components.
Be sure that any electrical components are properly wired and secured.
POWER
BREAKER/FUSE
TRIPPED
SUPPLY CORD NOT
PLUGGED IN OR IS
LOOSE IN POWER
RECEPTACLE
REPLACE SUPPLY
CORD IF RESETTING
DOES NOT CORRECT
UNIT'S POWER CORD
TRIPPED
3 MINUTE TIME DELAY
IS ACTIVATED
ELECTRICAL
COMPONENT
COMPR ISED 20
RE-TEST UNIT
TROUBLESHOOTING
THE SEALED SYSTEM
COMPONENTS
TEMPERATURE
SETTING IS NOT
BELOW ROOM
TEMPERATURE
SET TEMPERATURE SETTING
ABOVE (HEATING MODE) OR
BELOW (COOLING MODE)
ROOM TEMPERATURE
REPAIR OR REPLACED ALL
COMPROMISED SEALED
SYSTEM COMPONENTS
WEIGH IN UNIT'S SPECIFIC
REFRIGERANT CHARGE
TROUBLESHOOT
ELECTRICAL
COMPONENTS AND
REPAIR OR REPLACE
PLUG IN SECURELY
THE SUPPLY CORD
RESET SUPPLY
CORD'S LCDI
WAIT FOR THREE
MINUTES
FLOW CHART FOR TROUBLESHOOTING OF THE UNIT
---2---
Conditioned Supply
Air Louvers
Continuous Drain
Pump Outlet
Static Water
Drain Outlet
Return Air Grille
Room Air Filter
Outside Air Inlet
Exhaust Air Outlet
Power Supply Cord
Wheel Casters
19.50 inches
33.6 inches
15.5 inches
---3---

Especificaciones del producto

Marca: Friedrich
Categoría: aire acondicionado
Modelo: ZoneAire PH14B

¿Necesitas ayuda?

Si necesitas ayuda con Friedrich ZoneAire PH14B haz una pregunta a continuación y otros usuarios te responderán




aire acondicionado Friedrich Manuales

aire acondicionado Manuales

Últimos aire acondicionado Manuales