FSP Clippers 2k 2000VA Manual de Usario
FSP
Unión Postal Universal
Clippers 2k 2000VA
Lee a continuación 📖 el manual en español para FSP Clippers 2k 2000VA (34 páginas) en la categoría Unión Postal Universal. Esta guía fue útil para 3 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/34
User Manual
Clippers 1-3KVA
PF1.0 Online UPS
Uninterruptible Power Supply System
Version: 1.4
Table of Contents
1. Important Safety Warning ................................................................................... 1
1- Transportation 1. ....................................................................................................... 1
1- Preparation 2. ........................................................................................................ 1
1- Installation 3. ......................................................................................................... 1
1- Operation 4. ........................................................................................................... 1
1-5. Maintenance, service and faults ........................................................................... 2
2. Installation and setup .......................................................................................... 4
2-1. Rear panel view .................................................................................................. 4
2- Operating principle 2. ........................................................................................... 11
2-3. Install the UPS (Only for RT Models) .................................................................. 11
2-4. Setup the UPS .................................................................................................. 12
2-5. Battery Replacement (Only for RT Models) ......................................................... 15
2-6. Battery Kit Assembly (option for RT Models) ....................................................... 16
3. Operations .......................................................................................................... 18
3- Button operation 1. .............................................................................................. 18
3- LCD Panel 2. ........................................................................................................ 18
3- Audible Alarm 3. ................................................................................................... 20
3-4. LCD display wordings index ............................................................................... 20
3- UPS Setting 5. ...................................................................................................... 21
3-6. Operating Mode Description .............................................................................. 26
3-7. Faults Reference Code ....................................................................................... 27
3- Warning indicator 8. ............................................................................................. 27
4. Troubleshooting .................................................................................................. 28
5. Stor and Maintenance age ................................................................................... 29
6. Specifications ..................................................................................................... 30
1
Please comply with all warnings and operating instructions in this manual strictly. Save this
manual properly and read carefully the following instructions before installing the unit. Do not
operate this unit before reading through all safety information and operating instructions
carefully.
1-1. Transportation
Please transport the UPS system only in the original package to protect against shock
and impact.
1-2. Preparation
Condensation may occur if the UPS system is moved directly from cold to warm
environment. The UPS system must be absolutely dry before being installed. Please
allow at least two hours for the UPS system to acclimate the environment.
Do not install the UPS system near water or in moist environments.
Do not install the UPS system where it would be exposed to direct sunlight or near
heater.
Do not block ventilation holes in the UPS housing.
1-3. Installation
Do not connect appliances or devices which would overload the UPS system to
the UPS output sockets.
While connecting devices like laser printers, it is important to size your UPS
appropriately. The UPS has to be sized for the maximum power draw of the laser
printer as defined by the manufacturer.
Place cables in such a way that no one can step on or trip over them.
Do not connect domestic appliances such as hair dryers to UPS output sockets.
The UPS can be operated by any individuals with no previous experience.
Connect the UPS system only to an earthed shockproof outlet which must be easily
accessible and close to the UPS system.
Please use only VDE-tested, CE-marked (or UL-marked for 100/110/115/120/127 VAC
models) mains cable (e.g. the mains cable of your computer) to connect the UPS
system to the building wiring outlet (shockproof outlet).
Please use only VDE-tested, CE-marked (or UL-marked for 100/110/115/120/127 VAC
models) power cables to connect the loads to the UPS system.
When installing the equipment, it should ensure that the sum of the leakage current
of the UPS and the connected devices does not exceed 3.5mA.
Temperature Rating - Units are considered acceptable for use in a maximum ambient
of 40°C (104°F).
For Pluggable Equipment - The socket-outlet shall be installed near the equipment
and shall be easily accessible.
1-4. Operation
Do not disconnect the mains cable on the UPS system or the building wiring outlet
(shockproof socket outlet) during operations since this would cancel the protective
earthing of the UPS system and of all connected loads.
The UPS system features its own, internal current source (batteries). The UPS output
sockets or output terminals block may be electrically live even if the UPS system is not
connected to the building wiring outlet.
In order to fully disconnect the UPS system, first press the OFF/Enter button to
disconnect the mains.
Prevent no fluids or other foreign objects from inside of the UPS system.
1. Important Safety Warning
Especificaciones del producto
Marca: | FSP |
Categoría: | Unión Postal Universal |
Modelo: | Clippers 2k 2000VA |
¿Necesitas ayuda?
Si necesitas ayuda con FSP Clippers 2k 2000VA haz una pregunta a continuación y otros usuarios te responderán
Unión Postal Universal FSP Manuales
13 Septiembre 2024
13 Septiembre 2024
12 Septiembre 2024
12 Septiembre 2024
12 Septiembre 2024
12 Septiembre 2024
12 Septiembre 2024
12 Septiembre 2024
12 Septiembre 2024
12 Septiembre 2024
Unión Postal Universal Manuales
- Unión Postal Universal AEG
- Unión Postal Universal IKEA
- Unión Postal Universal HP
- Unión Postal Universal Apc
- Unión Postal Universal Lenovo
- Unión Postal Universal Tripp Lite
- Unión Postal Universal Energenie
- Unión Postal Universal Voltcraft
- Unión Postal Universal Adj
- Unión Postal Universal Digitus
- Unión Postal Universal LevelOne
- Unión Postal Universal Eaton
- Unión Postal Universal CyberPower
- Unión Postal Universal Block
- Unión Postal Universal Avocent
- Unión Postal Universal Minuteman
- Unión Postal Universal Maruson
- Unión Postal Universal V7
- Unión Postal Universal Phoenix Contact
- Unión Postal Universal Puls Dimension
- Unión Postal Universal Salicru
- Unión Postal Universal Equip
- Unión Postal Universal Murr Elektronik
- Unión Postal Universal Altronix
- Unión Postal Universal Ditek
- Unión Postal Universal Bxterra
- Unión Postal Universal Middle Atlantic
- Unión Postal Universal Atlantis Land
- Unión Postal Universal PowerWalker
- Unión Postal Universal FSP/Fortron
- Unión Postal Universal Online USV
Últimos Unión Postal Universal Manuales
24 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
20 Octubre 2024
18 Octubre 2024
18 Octubre 2024
12 Octubre 2024
12 Octubre 2024
12 Octubre 2024