Fujitsu Lifestyle ASTG30KMTA Manual de Usario

Fujitsu aire acondicionado Lifestyle ASTG30KMTA

Lee a continuación 📖 el manual en español para Fujitsu Lifestyle ASTG30KMTA (12 páginas) en la categoría aire acondicionado. Esta guía fue útil para 7 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/12
En-1
AIR CONDITIONER
Wall Mounted Type
ASTG30KMTA
ASTG34KMTA
OPERATING MANUAL
Before using this product, read these instructions thoroughly. Also, keep this manual for future reference,
together with the installation manuals for the indoor and outdoor units.
Safety Precautions
To prevent personal injury, injury to others, or property damage, read this section carefully before you use this product, and be sure to comply to the
following safety precautions.
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classied as follows:
WARNING CAUTION
This mark warns of death or serious injury. This mark warns of injury or damage to property.
This mark denotes an action that is PROHIBITED. This mark denotes an action that is COMPULSORY.
Explanation of symbols displayed on the indoor unit or outdoor unit.
WARNING This symbol shows that this appliance uses a ammable refrigerant. If the refrigerant is leaked and exposure to an external
ignition source, there is a risk of re.
CAUTION This symbol shows that the Operation Manual should be read carefully.
CAUTION This symbol shows that a service personnel should be handling this equipment with reference to the Installation Manual.
CAUTION This symbol shows that information is available such as the Operating Manual or Installation Manual.
WARNING
The appliance, outlet and inlet shall be installed, operated
and stored in a room with a oor area larger than X m
2.
30 type M (kg) M ≤ 1.65 1.65 < M 2.05 2.05 < M 2.45 2.45 < M 2.85
X (m2)2.60 4.01 5.72 7.74
34 type M (kg) M ≤ 2.00 2.00 < M 2.45 2.45 < M 2.90
X (m2)3.81 5.72 8.02
M (kg): Amount of refrigerant charge ( IEC 60335-2-40 )
X (m 2): Minimum room area
The appliance contains no user-serviceable parts. Always
consult authorized service personnel for repairing, installation,
and relocation of this product.
Improper installation or handling will cause leakage, electric
shock, or re.
In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning o the electrical
breaker or disconnecting the power plug. Then consult
authorized service personnel.
Take care not to damage the power supply cable.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualied persons
in order to avoid a hazard.
In the event of refrigerant leakage, be sure to keep away
from re or any ammables, and consult authorized service
personnel.
If you see lightning or hear thunder, there might be a lightning
strike.
To prevent electric shock hazard, turn o the air conditioner
by using the remote controller, and do not touch this product
or the power source during thunderstorm.
The appliance shall be stored in a room without continuously
operating ignition sources (for example: open ames, an
operating gas appliance or an operating electric heater).
The appliance shall be stored in a well-ventilated area.
Be aware that refrigerants may not contain an odour.
The appliance shall be stored so as to prevent mechanical
damage from occurring.
Disposing of the product shall be done properly, in
compliance with national or regional regulations.
During transportation or relocation of the indoor unit, pipes
shall be covered with the wall hook bracket for protection.
Do not move the appliance by holding the indoor unit pipes.
(The stress applied to the pipe joints may cause the
ammable gas to leak during operation).
(continued)
Contents
Safety Precautions ..........................................................En-1
Indoor Unit Overview and Operations .............................En-3
Remote Controller Overview and Operations ..................En-4
Timer Operation...............................................................En-6
Human Sensor (Energy Saving) ......................................En-8
Demand Response and Indoor Unit Operation ...............En-8
General Informations on Operation .................................En-9
Cleaning and Care.........................................................En-10
Troubleshooting .............................................................En-12
R32
REFRIGERANT
This Air Conditioner contains and
operates with refrigerant R32.
THIS PRODUCT MUST ON BE INSTALLED OR SERVICEDLY
BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance or service of this product.
PART No. 9387081015
En-2 OPERATING MANUAL
WARNING
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
Do not use inammable gases near this product.
Do not expose yourself directly to the cooling airow for
many hours.
Do not insert your ngers or any other objects into outlet port
or inlet port.
Do not operate with wet hands.
Do not use means to accelerate the defrosting process or to
clean the appliance, other than those recommended by the
manufacturer.
Do not pierce or burn.
Do not install the unit in area lled with mineral oil such as a
factory or area containing a large amount of splashed oil or
steam such as a kitchen.
Do not start or stop the operation of this product by turning
on or o the circuit breaker.
CAUTION
Provide occasional ventilation during use.
Always operate the unit with air lters installed.
Ensure that any electronic equipment is at least 1 meter
away from either the indoor unit or outdoor unit.
Turn o power source when not using this product for
extended periods.
After long period of use, check whether the installation stand
does not deteriorate to prevent the unit from falling down.
The airow direction and the room temperature should be
carefully considered when you use this product in a room
with infants, children, elderly or sick persons.
Do not place any other electrical products or household
belongings under this product.
Dripping condensation from this product might get them wet,
and may cause damage or malfunction of your property.
Do not expose this product directly to water.
Do not use this product for preservation of food, plants,
animals, precision equipment, art work, or other objects. This
may cause quality deterioration of those items.
Do not expose animals or plants to the direct airow.
Do not drink the drainage from the air conditioner.
Do not pull the power supply cable.
Do not touch the aluminum ns of heat exchanger built-in this
product to avoid personal injury when you install or maintain
the unit.
Do not direct the airow at replaces or heating apparatus.
Do not block or cover the intake grille and the outlet port.
Do not apply any heavy pressure to radiator ns.
Do not climb on, place objects on, or hang objects from this
product.
Safety Precautions (continued)
Indoor unit accessories
Remote
controller
Batteries Filter holdersAir cleaning lters
Remote controller
holder
Tapping screws
Remote controller holder installation
321
Screws
Insert
Slide up
WARNING
Take care to prevent infants and young children from acciden-
tally swallowing the batteries.
CAUTION
Do not attempt to recharge dry batteries.
Do not use dry batteries that has been recharged.
Battery (R03/LR03/AAA × 2) loading and remote controller preparation
4
2
3
16
7
8
5
9
5 Press "CLOCK ADJUST" button to start clock setting.
6 Set the day of the week by pressing "SELECT" button (Monday
to Sunday). *By pressing the "TEMP.
( / ) " buttons, the time
indicator can be changed from a 24-hour to a 12-hour clock.
7 Press "NEXT" button to continue.
8 Set the time by pressing "SELECT" button.
Pressing or changes the value by the minute.
Pressing down on or changes the value by 10 minutes.
9 To complete, press the "SEND" button close to the indoor unit.
Settings may not be properly sent if pressed from a distance.
Notes:
Use specied type of batteries only.
Do not mix dierent types or new and used batteries together.
Batteries can be used about 1 year in ordinary use.
If the remote control range noticeably shortens, replace the batter-
ies, and press "RESET" button as shown in .page 5
En-3
AIR CONDITIONER Wall Mounted Type
OPERATING MANUAL
1 Intake grille
Before starting operation, make sure that the intake grille has been
shut completely. Incomplete closing may have an eect on the proper
function or performance of the product.
2 "MANUAL AUTO" button
Use when the remote controller is lost or there is a malfunction.
Status Action Mode or operation
In operation Press. Stop
Stopping AUTOPress less than 10 seconds.
Press more than 10 seconds.
(Only for servicing.*)
Forced cooling
*:To stop forced cooling, press this button or "Start/Stop( )" button
on the remote controller.
3 Front panel
See page 8
4 Human Sensor
Used for Energy Saving Program. Controls temperature setting by
detecting people in the room.
5 Vertical airow direction louver
Each time you press "Vertical SET" button on the remote controller,
the angle of the vertical airow direction louver moves as follows:
1
2
3
4
5
6
COOL or DRY mode HEAT mode
1 2 3 65
* *
4
*: Default setting in each mode.
Do not adjust by hand.
At the beginning of AUTO or HEAT mode, they may stay on position
1 for a while for adjustment.
If the angle is set to position 4-6 for more than 20 minutes in COOL
or DRY mode, the louver will automatically return to position 3.
Keeping the position 4-6 during COOL or DRY mode may cause
condensation to form, and the drops may damage your property.
6 Horizontal airow direction louver
Each time you press the "Horizontal SET" button on the remote
controller, the airow direction range of the horizontal airow direction
louver will change as follows:
12
3
4
5
Horizontal airow direction louver
5 4 1 3
*2
*: Default setting.
7 Drain hose
8 Remote controller signal receiver
CAUTION
For appropriate signal transmission between remote controller and
indoor unit, keep the signal receiver away from the following items
:
-Direct sunlight or other strong lights
- Flat-panel television screen
In rooms with instantaneous uorescent lights, such as in-
verter type ones, the signal may not be transmitted properly. In
such a case, consult the store of purchase.
13
1
2
3
4
5
8
9
7
6
10
11
12
9
ECONOMY indicator (green)
Lights in ECONOMY operation and in 10 °C HEAT operation.
10
TIMER indicator (orange)
Lights in TIMER operation, and blinks slowly when the timer setting
error is detected.
For details, refer to .“Auto-restart function” on page 9
11 OPERATION indicator (green)
Lights in normal operation, and blinks slowly in Automatic defrosting
operation.
Blinks during Demand Response operation. For details, refer to page
8.
See page 10
12
Air lter
See page 11
13
Air cleaning lters
Purify or deodorize the air, and provide fresh airow
Indoor Unit Overview and Operations

Especificaciones del producto

Marca: Fujitsu
Categoría: aire acondicionado
Modelo: Lifestyle ASTG30KMTA

¿Necesitas ayuda?

Si necesitas ayuda con Fujitsu Lifestyle ASTG30KMTA haz una pregunta a continuación y otros usuarios te responderán




aire acondicionado Fujitsu Manuales

aire acondicionado Manuales

Últimos aire acondicionado Manuales