Installation Manual
RADAR SENSOR
DRS2D/DRS4D/
DRS4A/DRS6A/DRS12A/DRS25A
SAFETY INSTRUCTIONS ............................................................................ i
SYSTEM CONFIGURATION ....................................................................... ii
EQUIPMENT LISTS.................................................................................... iv
1. MOUNTING ............................................................................................ 1
1.1 Mounting Considerations..............................................................................................1
1.2 Mounting Procedure for DRS2D/4D .............................................................................2
1.3 Mounting Procedure for DRS4A/6A/12A/25A...............................................................3
1.4 Mounting of Power Supply Unit .................................................................................... 8
2. WIRING ................................................................................................ 11
2.1 Wiring inside DRS2D/4D ............................................................................................15
2.2 Wiring inside DRS4A/6A/12A/25A..............................................................................19
2.3 Wiring of Power Supply Unit.......................................................................................23
SPECIFICATIONS ................................................................................. SP-1
PACKING LISTS...................................................................................... A-1
OUTLINE DRAWINGS............................................................................. D-1
INTERCONNECTION DIAGRAMS.......................................................... S-1
i
WARNING WARNING
Wear a safety belt and hard hat when
working on the antenna unit.
Serious injury or death can result if
someone falls from the radar mast.
Model Distance to
100 W/m2point
Distance to
10 W/m2point
DRS4A Nil 1.20 m
Nil 1.20 m
CAUTION
Do not open the equipment unless
totally familiar with electrical circuits
and service manual.
Only qualified personnel should work
inside the equipment.
Ground the equipment to prevent
electrical shock and mutual
interference.
Model Standard Steering
DRS4A 0.80 m 0.50 m
DRS6A 0.85 m 0.55 m
Radio Frequency Radiation Hazard
DRS6A
SAFETY INSTRUCTIONS
DRS12A
DRS2D Nil 0.40 m
0.10 m 1.40 m
DRS4D
DRS4D
1.40 m 0.85 m
DRS2D 1.35 m 0.80 m
0.20 m 2.40 mDRS12A (XN12A)
DRS12A (XN13A) 0.20 m 1.90 m
1.15 m 0.70 m
PSU-012
0.30 m 0.30 m
PSU-013
0.30 m 0.30 m
DRS25A 1.00 m 0.60 m
0.50 m 5.30 m
DRS25A (XN12A)
DRS25A (XN13A) 0.40 m 4.40 m
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
Read these safety instructions before installing the equipment.
WARNING
Indicates a potentially hazardous situation which, if not avoided,
canresult in minor or moderate injury.
Warning, Caution Prohibitive Action
CAUTION
Mandatory Action
The radar antenna emits electromagnetic radio
frequency (RF) energy which can be harmful,
particularly to your eyes. Never look directly into
the antenna aperture from a close distance while
the radar is in operation or expose yourself to the
transmitting antenna at a close distance.
Distances at which RF radiation levels of 100 and
10 W/m2 exist are given in the table below.
Note: If the antenna unit is installed at a close
distance in front of the wheel house, your
administration may require halt of transmission
within a certain sector of antenna revolution. This
is possible - Ask your FURUNO representive or
dealer to provide this feature.
Construct a suitable service platform
from which to install the antenna
unit.
Serious injury or death can result if the
power is left on or is applied while the
equipment is being installed.
Turn off the power at the mains
switch board before beginning the
installation.
Fire, electrical shock or serious injury
can result if the power is left on or is
applied while the equipment is being
installed.
Observe the following compass safe distance
to prevent deviation of a magnetic compass.
PSU-017
0.30 m 0.30 m

Especificaciones del producto

Marca: Furuno
Categoría: No categorizado
Modelo: DRS12A

¿Necesitas ayuda?

Si necesitas ayuda con Furuno DRS12A haz una pregunta a continuación y otros usuarios te responderán




No categorizado Furuno Manuales

No categorizado Manuales

Últimos No categorizado Manuales