Gemini 931PSA Manual de Usario
Gemini
alarma de coche
931PSA
Lee a continuación 📖 el manual en español para Gemini 931PSA (4 páginas) en la categoría alarma de coche. Esta guía fue útil para 7 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/4
Made in Italy AC 2793 Rev. 00 - 09/10
................................................
..........................................................................................................................
931 PSA
931 PSA
UK
INSTALLATION AND
USE MANUAL
INSTALLATION CERTIFICATE
The undersigned qualified installer attests to have personally fitted the here described vehicle
security system following the manufacturer instructions.
By :
Sold on : T:ype of product
Vehicle :
GEMINI Technologies S.p.A.
Via Luigi Galvani 12 - 21020 Bodio Lomnago (VA) - Italia
Tel. +39 0332 943211 - Fax +39 0332 948080
Web site: www.gemini-alarm.com
Reg. n.532-A
UNI EN ISO 9001:2008
1.0
2.0
3.0
4.0
5.0
6.0
- PRELIMINARY ADVICE.............................................................................................
- WARRANTY CONDITIONS ..................................
- OPERATING DESCRIPTION.....................................................................................
3.1 - Complete system arming.........................................................................................
3.2 - Arming inhibit time....................................................................................................
3.3 - System armed..........................................................................................................
3.4 - Alarm, inhibit time between alarms and alarm cycles..............................................
3.5 - System disarming.....................................................................................................
3.6 - Alarm memory...........................................................................................................
- CONNECTORS TABLES............................................................................................
4.1 - 20-way connector.....................................................................................................
4.2 - 8-way connector.......................................................................................................
- COMPLETE ELECTRIC DIAGRAM...........................................................................
- ............................................................
............................................................................
............................................................................................
WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE) DIRECTIVE.......
- TECHNICAL SPECIFICATIONS...............................................................................
USER MANUAL
INSTALLER MANUAL
.....................................................
ULTRASONIC VOLUMETRIC PROTECTION
6.1 - Connections and positioning........
6.2 - Sensor adjustment........
-7.0
8.0
PAGE 02
1.0 - PRELIMINARY ADVICE
Dear Customer, the present manual illustratesthe 931 PSA CAN enabled alarm system, custom
designed for Peugeot/Citroën vehicles.
Throughout this manual specific operating modes or connections are highlighted by the following
signs:
USER MANUAL- PAGE 03
UK TABLE OF CONTENTS
For the installer.
This
.
sign indicates that the functionning of the system can vary according to
connections and programming of the system or it simply provides useful indications for
the installation
!
For the user.
This sign highlights useful information.
3.0 - OPERATING DESCRIPTION
USER M NUALA
3.1 - COMPLETE SYSTEM ARMING
3.2 - ARMING INHIBIT TIME
3.3 - SYSTEM ARMED
3.4 - ALARM, INHIBIT TIME BETWEEN ALARMS AND ALARM CYCLES
3.5 - SYSTEM DISARMING
Press the lock button on the original remote control of the vehicle; the system arming is confirmed by
t30”().
System inhibit arming time lasts approximately 30 seconds and is indicated by the status LED on;
.
After the inhibit time the system is “armed” and ready to detect any theft attempt.
When the system is fully armed, the LED flashes.
The system theft attempt indicated optic signals (turn indicators) and acoustic
signals (vehicle horn).
before another alarm starts, there are 5” of “neutral time”.
The alarm signalling has 10 cycles of 30” each for input and system arming cycles.
Press the unlock button on the original remote control of the vehicle; the system disarming is
confirmed by the status LED off (blinking).
.
(3.6) for possible causes and signals.
he LED turned on steady for pre-arming “neutral time”
s is by the system with
After the alarm has been triggered, but
If an alarm has occurred, the LED starts flashing when ignition key is turned “ON” to signal the last
alarm type
See relative paragraph
it is
possible to exit the vehicle without triggering any alarm
LED SIGNALS ALARM CAUSES Nr. OF ALARM
CYCLES
10
10
10
10
Starting attempt (+15/54)
Doors opening
Bonnet opening
Volumetric sensor
LED ON (1 second)LED OFF (2 seconds)
2.0 - WARRANTY CONDITIONS
This product is guaranteed to be free from manufacturing defects for a period of 24 months from the
installation date shown on this warranty, in compliance with the directive 1999/44/CE.
Please fill-in entirely the guarantee certificate included in this booklet and do NOT REMOVE the
guarantee label from the device.
The warranty will become void if labels are missing or torn, if the installation certificate is not fully
compiled or if the enclosed sale document is missing.
The guarantee is valid exclusively at Authorized Gemini Technologies S.p.A. Centers.
The manufacturer declines any responsibility for eventual malfunctions of the device or any damage
to the vehicle electrical system due to improper installation, use or tampering.
This alarm system is solely intended to be a theft-deterrent device.
PAGE 02
PAGE 03
PAGE 03
PAGE 03
PAGE 03
PAGE 03
PAGE 03
PAGE 03
PAGE 04
PAGE 04
PAGE 04
PAGE 05
PAGE 05
PAGE 05
PAGE 05
PAGE 0B
PAGE 0B
PAGE 02
3.6 - ALARM MEMORY
,t
.
As previously mentioned, the LED memory allows you to identify the last alarm cause.
After disarming the system urn the ignition key “ON” and look at the vehicle status LED; the blinks
indicates the last alarm condition.
The optic signals are repeated 3 times; to interrupt, turn ignition key “OFF”.
The alarm trigger signals and relative causes are indicated in the table below
To disarm the system in case of emergency (remote control out of order), simply turn ignition
key “ON” with system armed.
This type of disarming can ONLY be done with the vehicle ORIGINALKEY.
INSTALLER MANUAL - PAGE 05PAGE 04 - INSTALLER MANUAL
INSTALLER MANUAL
BLACK
RED
6-way connector to plug into
the free connector
on the BSI control unit
marked
“EA”
5.0 - COMPLETE ELECTRIC DIAGRAM
CAN BUS signal
LIGHT BLUE (CAN-L)
LIGHT BLUE-GREY (CAN-H)
3
1
6
4
6.0-U
6.1 - CONNECTIONS AND POSITIONING
6.2 - SENSOR ADJUSTMENT
Insert the WHITE connector
.
:
.
LTRASONIC VOLUMETRIC PROTECTION
in the the “W” socket on the control unit.
Insert the RED connector in the “R” socket on the control unit.
Install the transducers of the ultrasonic sensors on the top part of the windscreen internal pillars, away
from the aeration inlets and orient them towards the center of the rear window
o check sensors proceed as follows
With system disarmed, roll down the front window approx. 20 cm.
Set the trimmer on the control unit to the middle position.
Close doors, bonnet and boot and arm the system.
During the system inhibit arming time, introduce an object in the cabin and move it around; the
status LED will turn off to signal a presence.
If sensibility level is too low, adjust trimmer again and repeat above procedure
!
!
!
!
!
ULTRASONIC
CELLS
CONNECTIONS
SENSIBILITY
ADJUSTMENT
4.0 - CONNECTORS TABLES
Ground
-----
Positive
-----
-----
-----
-----
-----
-1-
-2-
-3-
-4-
-5-
-6-
-7-
-8-
-9-
-10-
-11-
-12-
-13-
-14-
-15-
-16-
-17-
-18-
-19-
-20-
-1-
-2-
-3-
-4-
-5-
-6-
-7-
-8-
-----
-----
-----
-----
-----
-----
BROWN
BLACK
RED
-----
LIGHT BLUE-GREY
LIGHT BLUE
PINK
GREEN-BLACK
-----
-----
-----
-----
-----
----
BLACK
-----
RED
-----
-----
-----
-----
-----
WIRE FUNCTION
WIRE FUNCTION
POSITION
POSITION
WIRE COLOUR
WIRE COLOUR
4.1 - 20-WAY CONNECTOR
4.2 - 8-WAY CONNECTOR
-----
-----
-----
-----
-----
-----
Grund for external sensor connector
LED negative output
LED positive output
-----
CAN BUS signal (CAN-H)
CAN BUS signal (CAN-L)
Positive output with system armed (+A)
External sensor negative input
-----
-----
-----
-----
-----
-----
For the system to work properly, the “original alarm installed” feature (BSI unit)
must first be enabled via the specific diagnostic tester available at any authorized
Peugeot-Citroën dealer (PSA group).
Moreover, this type of system DOES NOT require that you program the vehicle
code, it is already factory-registered by Gemini.
NEVER PRESS THE PROGRAMMING BUTTON LOCATED NEXT TO THE UNIT
BUILT-IN LED
!
Before carrying out all
electrical connections,
disconnect the
negative battery
terminal and re-
connect again after
completion.
!
Red
Black
Connector for external modules
Pink
Brown
Green-Black
Especificaciones del producto
Marca: | Gemini |
Categoría: | alarma de coche |
Modelo: | 931PSA |
¿Necesitas ayuda?
Si necesitas ayuda con Gemini 931PSA haz una pregunta a continuación y otros usuarios te responderán
alarma de coche Gemini Manuales
23 Septiembre 2024
20 Septiembre 2024
15 Septiembre 2024
26 Agosto 2024
24 Agosto 2024
19 Agosto 2024
15 Agosto 2024
14 Agosto 2024
29 Julio 2024
28 Julio 2024
alarma de coche Manuales
Últimos alarma de coche Manuales
4 Septiembre 2024
3 Septiembre 2024
29 Julio 2024
18 Julio 2024