Hitachi RAS-08CH8B Manual de Usario
Hitachi
aire acondicionado
RAS-08CH8B
Lee a continuación 📖 el manual en español para Hitachi RAS-08CH8B (2 páginas) en la categoría aire acondicionado. Esta guía fue útil para 5 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/2
SPLIT UNIT AIR CONDITIONER
INSTALLATION MANUAL
Indoor Unit Outdoor Unit
RAS-08CH8/RAS-08CH8(B) RAC-08CH8
RAS-10CH8/RAS-10CH8(B) RAC-10CH8
RAS-14CH8/RAS-14CH8(B) RAC-14CH8
● + – Screwdriver ● Measuring Tape ● Knife
● Saw ● ø 65mm Power Drill ● Hexagonal Wrench
Key ( 4mm) ● Wrench (14, 17, 22mm) ●
Gas
Leakage Detector ● Pipe Cutter ● Putty ● Vinyl
Tape ● Pliers ● Flare Tool
●Carefully read through the procedures of proper
installation before starting installation work.
●The sales agent should inform customers regarding
the correct operation of installation.
Tools Needed For Installation Work
SAFETY PRECAUTION
●Read the safety precautions carefully before operating the unit.
●The contents of this section are vital to ensure safety. Please pay special attention to the following sign.
WARNING ........ Incorrect methods of installation may cause death or serious injury.
CAUTION ......... Improper installation may result in serious consequence.
Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating
the unit as described in the user’s guide.
!
!
WARNING
!
CAUTION
!
●A circuit breaker or fuse must be installed. Without a circuit breaker or fuse the danger of electric shock exists.
A main switch with a contact gap of more than 3mm has to be installed in the power supply line to the outdoor unit.
●Do not install the unit near a location where there is flammable gas. The outdoor unit may
catch fire if flammable gas leaks around it.
●Please ensure smooth flow of water when installing the drain hose.
●Piping shall be suitable supported with a maximum spacing of 1m between the supports.
●Please request your sales agent or qualified technician to install your unit. Water leakage, short circuit or fire may occur if you
do the installation work yourself.
●Please observe the instructions stated in the installation manual during the process of installation. Improper installation may
cause water leakage, electric shock and fire.
●Make sure that the units are mounted at locations which are able to provide full support to the weight of the units. If not, the
units may collapse and impose danger.
●Observe the rules and regulations of the electrical installation and the methods described in the installation manual when
dealing with the electrical work. Use power cables approved by the authorities of your country.
●Be sure to use the specified wire for connecting the indoor and outdoor units. Please ensure that the connections are tight
after the conductors of the wire are inserted into the terminals. Improper insertion and loose contact may cause over-heating
and fire.
●Please use the specified components for installation work. Otherwise, the units may collapse or water leakage, electric shock
and fire may occur.
●Be sure to use the specified piping set for R22. Otherwise, this may result in broken copper pipes or faults.
●When installing or removing an air conditioner, do not allow air or moisture to remain in the refrigeration cycle. Otherwise,
pressure in the refrigeration cycle may become abnormally high so that a rupture may be caused.
●Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes into contact with fire, a poisonous
gas may occur.
●After completion of installation work, check to make sure that there is no refrigeration gas leakage. If the refrigerant gas leaks
into the room, coming into contact with fire in the fan-driven heater, space heater, etc., a poisonous gas may occur.
●Unauthorized modifications to the air conditioner may be dangerous. If a breakdown occurs please call a qualified air conditioner
technician or electrician. Improper repairs may result in water leakage, electric shock and fire, etc.
FOR SERVICE PERSONNEL ONLY
THE CHOICE OF MOUNTING SITE (Please note the following matters and obtain permission from customer before installation).
WARNING
!
●The unit should be mounted at stable, non-vibratory location which
can provide full support to the unit.
WARNING
!
●The Outdoor unit must be mounted at a location which can sup-
port heavy weight. Otherwise, noise and vibration will increase.
CAUTION
!
●
No nearby heat source and no obstruction near the air outlet is allowed.
●
The clearance distances from top, right and left are specified in figure
below.
●
The location must be convenient for water drainage and pipe connection
with the Outdoor unit.
●
To avoid interference from noise please place the unit and its remote
controller at least 1m from the radio, television and inverter type fluorescent
lamp.
●
To avoid any error in signal transmission from the remote controller,
please put the controller far away from high-frequency machines and
high-power wireless systems.
●
The installation height of indoor unit must be 2.3m or more.
CAUTION
!
●
Do not expose the unit under direct sunshine or rain. Besides, ventilation
must be good and clear of obstruction.
●
The air blown out of the unit should not point directly to animals or plants.
●
The clearances of the unit from top, left, right and front are specified in figure
below. At least 3 of the above sides must be open air.
●
Be sure that the hot air blown out of the unit and noise do not disturb the
neighbourhood.
●
Do not install at a location where there is flammable gas, steam, oil and
smoke.
●
The location must be convenient for water drainage.
●
Place the Outdoor unit and its connecting cord at least 1m away from the
antenna or signal line of television, radio or telephone. This is to avoid noise
interference.
●
Do not install outdoor unit facing strong wind direction. It may damage the
fan motor.
INDOOR UNIT
Names of Indoor Components
Hanger
QtyNo. Item
The Length of Indoor Unit
Connecting Cord
Figure showing the Installation
of Indoor and Outdoor Unit.
OUTDOOR UNIT
11
Screw for holder of
Remote Controller
( 3 . 1 x 1 6 )
AAA Size Battery
Direction of Piping
Dimension of Mounting Stand
of the Outdoor unit
(unit : mm)
Holder for Remote
Controller There are 4 directions
allowed, namely, horizontally
perpendicular to the unit,
vertically down from right,
horizontally out from right and
horizontally out to left.
Don’t form the piping
downward at the left of the unit.
( 4 . 1 x 3 2 )
Remote Controller
Purifying Filter
26
31
42
52
6
7
9
1
0
1
Screw for Hanger
Names of Outdoor Components
QtyNo. Item
Drain Pipe
1
0.8m 1.5m
Connection
Horizontally
perpendicular
to the unit
500
100
35
35
12
225
8
mounting stand
!
CAUTION
• The installation height
of indoor unit must be
2.3m or more.
Bush
2
8
Holder
1
!2
Bush
@
Bush
1
For RAC-08/10CH8 only
For RAC-14CH8 only
For RAC-14CH8 only
above 50mm
above 100mm
above
0.45m
above 300mm
must not bend
above 100mm
2,300mm or more
12
4
5
3
Maximum pipe length 10m
Minimum pipe length 5m
Plug
6
above 100mm
❈ above 300mm above 200mm
❈ above 100mm
❈ give clearance
as wide as
possible
above 50mm when
installed on the
ceiling of balcony
above 200mm
●The difference in height between
the indoor and outdoor unit should
be kept max 10m.
●The connecting pipe, no matter big
or small, should all be insulated
with insulation pipe and then
wrapped with vinyl tape. (The
insulator will deteriorate if it is not
wrapped with tape).
The connection of insulated drain hose.
Please use insulated drain hose for the
indoor piping (commercial product).
The indoor piping should be
insulated with the enclosed
insulation pipe. (If the insulator
is insufficient, please use
commersial products).
inner diameter 16mmø
Be sure to
completely
seal any
gap with
putty.
Maximum pipe length 15m
Minimum pipe length 5m
above 200mm
above 700mm
above 200mm
)
above 100mm
above 100mm
give clearance as
wide as possible
above 50mm when
installed on the
ceiling of balcony
(
For RAC-08/10CH8 only
Dimension of Mounting Stand
of the Outdoor unit
(unit : mm)
57
12
35
124
500
320 10
20
(10)
340
mounting stand
For RAC-14CH8 only
For RAC-14CH8 only
Installation of Hanger, Wall Penetration and Installation of Protection Pipe
1
CAUTION
!
●The draining of the water container inside the indoor unit can be done from the left.
Therefore the hanger must be fixed horizontally or slightly tilted towards the side of
drain hose. Otherwise, condensed water may overflow the water container.
Direct Mounting On The Wall
●Please use hidden beams in the wall to hold the hanger.
Wall Penetration and Installation of Protection Pipe
●Drill a 65mm hole onø
wall which is slightly tilted
towards the outdoor side.
Drill the wall at a small
angle.
●Cut the protection pipe
according to the wall
thickness.
●Empty gap in the sleeve
of protection pipe should
be completely sealed
with putty to avoid
dripping of rain water into
the room.
Procedures of Installation and Precautions
●Procedures to fix the hanger.
1. Drill holes on wall. 2. Push plug into the holes. 3. Fix the hanger on wall
(As shown below) (As shown below) with 4.1 x 32 screw
(As shown in figure below)
●Procedures to fix the holder of remote control.
1. Drill holes on wall. 2. Push plug into the holes.
(As shown below) (As shown below)
Installation of the Indoor Unit2
VERTICALLY DOWNWARD PIPING
Preparation
●Connect connecting cord.
●Pull out the pipe, connecting cord and drain hose.
Installation
●The upper part of the Indoor unit is hanged on the hanger.
●The projection at the lower part of the Indoor unit is hooked onto the hanger.
Please pull the lower part of
the Indoor unit outwards to
check if the unit is hooked
onto the hanger. Improper
installation may cause
vibration and noise.
!
CAUTION
HORIZONTAL PIPING
Preparation
Change of Drain Hose and Installation Procedures.
●
Exchange the location of drain hose and drain cap during horizontal piping as shown in
figure below. Be sure to plug in the drain hose until the insulating material folds upon itself.
●Please use pliers to pull out the drain cap.
(This is an easier way to remove the drain cap).
INSTALLATION OF REFRIGERATING PIPES AFTER CONNECTION
●The refrigerating pipes should be adjusted to fit into
the hole on the wall and then ready for further
connection.
●The terminals of 2 connected pipes must be covered
with insulator used for terminal connection. Then the
pipes are wrapped with insulation pipe.
●Connect the connecting cord after removing electrical
cover. (Refer to “CONNECTION OF POWER CORD”)
●After adjustment, fit the connecting cord and pipes
into the space available under the indoor unit. Use
holder to hold them tight.
!
CAUTION
●
The rubber strap used for
fixing the insulator should
not be tied with great force.
Otherwise, this will damage
heat insulation and causes
water condensation.
●Holder can be attached at the either of 2 places.
Please select the easier position.
THE CONNECTION OF REFRIGERATING PIPE DURING THE
INSTALLATION OF INDOOR UNIT
Preparation To Install Refrigerating Pipes
!
CAUTION
●Please fix in the plastic core
after flaring to avoid plastic
chips entering the pipes.
CAUTION
!
You are free to choose the side (left or right) for the installation of drain
hose. Please ensure the smooth flow of condensed water of the Indoor
unit during installation. (Carelessness may result in water leakage.)
!
CAUTION
Be sure that the
drain hose is not
loosely connected
or bend.
Be sure that the wire is not
in contact with any metal
in the wall. Please use the
protection pipe as wire
passing through the hollow
part of the wall so as to
prevent the possibility of
damaged by mouse.
Unless it seals completely,
any air with high humidity
flows from outdoor and
any dew may drop.
!
WARNING
●The refrigerating pipes and connecting cord
transform and are attached.
●The end of the refrigerating pipes are at locations
marked with symbol.“ ”
Installation of Drain Hose
3
Installation
Hang the Indoor unit onto the hanger. Use the temporary stand
at the back of the Indoor unit to push its lower part 15cm
forwards.
●Place the drain hose through the hole on the wall.
●Wrap the refrigerating pipes with insulation pipe after
connecting refrigerating pipe.
●Connect the connecting cord after removing electrical cover.
(Refer to Connection of Power Cord“ ”)
●After adjustment, the connecting cord and refrigerating pipes
are placed into the space available under the Indoor unit.
●The projection of Indoor unit must hook to the hanger.
INDOOR UNIT
<
IA321: A
>
HOW TO REMOVE INDOOR UNIT
●Push up the (PUSH) sections at the
bottom of the indoor unit and pull the
bottom plate towards you. Then the
claws are released from the stationary
plate.
(The (PUSH) sections are indicated by
2 arrows in the right figure)
Sleeve of
protection
pipe
WALL
Protection
pipe
Seal with
putty
Seal with
putty
2 ~ 5mm
OutdoorIndoor
Connecting cords, pipe and
drain hose must be laid
together with Vinyl tape.
Lift the body
of the unit
upwards and
then force it
downwards.
Hanger
Refrigerating
Pipe
Protection
Pipe Drain Hose Connecting
Cord
Hanger
1
Projection
2
[Push] mark positions
!
CAUTION Condensed water may leak out if not inserted properly.
HORIZONTAL & DOWNWARD PIPING – MAKING OPENINGS
●During horizontal or downward piping, use a knife to cut
openings as shown in figure. Then smoothen the edges of
openings with a file.
●Turn the piping while holding down the lower
portion of pipe-support by hand.
Drain hoseDrain cap
Drain cap
Please insert
until here
Drain hose
Please insert
until here
Pipe
support
Pull up the pipe after
bending downward
Openings
Pipe
Connecting
cord
Drain hose
Insulation pipe (must be wrapped with
vinyl tape at every 120mm).
8 Holder
Pipe Rubber strap tied with great force
below
5mm
Please bend at a small
radius to form an arc
0.85m
about 15cm
Hook
Projection
Protection pipe
Connecting cord
Holder Connected section
Drain hose
HITAC H
I
Heat insulation pipe
Connecting
cord
Refrigerating pipe
Bending
upwards
Condensed
water pond
Ditch Condensed
water pond
Pull this to the front
during the connection
of refrigerating pipes to
ease task.
125mm
45mm
200mm
60mm
80mm
780mm
125mm
280mm
45mm
115mm
450mm
Level
Hanger
Hole for pipe
Weight
Mark
Line
Please use more
than 4 screws.
Screw for Hanger
OUTDOOR UNIT
Removal Of Air From The Pipe And Gas Leakage Inspection
Gas Leakage Inspection
Please use gas leakage detector to check if leakage
occurs at the connection of Flare nut as shown on
the right.
If gas leakage occurs, further tighten the connection
to stop leakage.
FINAL STAGE OF INSTALLATION
Insulation And Maintenance Of Pipe Connection
1
●The connected terminals should be completely sealed with
heat insulator and then tied up with rubber strap.
●Please tie the pipe and power line together with vinyl tape as
shown in the figure showing the installation of Indoor and
Outdoor units. Then fix their position with holders.
●To enchance the heat insulation and to prevent water
condensation, please cover the outdoor part of the drain hose
and pipe with insulation pipe.
●Completely seal any gap with putty.
Installation Of Remote Controller2
Power Source And Operation Test3
●The remote controller can be placed in its holder which is
fixed on wall or beam.
●To operate the remote controller at its holder, please ensure
that the unit can receive signal transmitted from the controller
at the place where the holder is to be fixed. The unit will beep
when signal is received from the remote controller. The signal
transmission is weaken by the fluorescent light. Therefore,
during the installation of the remote control holder, please
switch on the light, even during day time, to determine the
mounting location of the holder.
Power Source
CAUTION
!
●Please use a new socket. Accident may occur due to the use of old
socket because of poor contact.
●Please plug in and then remove the plug for 2 – 3 times. This is to
ensure that the plug is completely plugged into the socket.
●Keep additional length for the power cord and do not render the
plug under external force as this may cause poor contact.
●Do not fix the power cord with U-shape nail.
Operation Test
●Please ensure that the air conditioner is in normal
operating condition during the operation test.
●Explain to your customer the proper operation
procedures as described in the user’s manual.
<
IA321: A
>
The controller must
be hooked onto the
hook at the lower
part of the holder.
Push in the remote
controller in the
direction as shown
in figure below.
3
Procedures of using Vacuum Pump for Air Removal
As shown in right figure, remove the cap
of valve core. Then, connect the charge
hose. Remove the cap of valve head.
Connect the vacuum pump adapter to
the vacuum pump and connect the
charge hose to the adapter.
Fully tighten the “Hi” shuttle of the
manifold valve and completely unscrew
the “Lo” shuttle. Run the vacuum pump
for about 10–15 minutes, then completely
tighten the “Lo” shuttle and switch off
the vacuum pump.
2
Completely unscrew the spindle of the
service valve (at 2 places) in anti-
clockwise direction to allow the flow of
coolant (using Hexagonal Wrench key).
3
Remove the charge hose and tighten the
cap of valve head. Check the cap’s
periphery if there is any gas leakage.
The task is then completed.
4
1
Preparation of Pipe1
●Use a pipe cutter to cut the copper pipe.
●Jagged edge will cause leakage.
●Point the side to be trimmed downwards during trimming to prevent copper
chips from entering the pipe.
●Before flaring, please put on the flare nut.
Pipe Connection2
INSTALLATION OF REFRIGERATING PIPES AND AIR REMOVAL
CAUTION
!
AIR REMOVAL
WARNING
●If you cannot attach the side cover due to the
connecting cord, press the connecting cord in
direction to the front panel to fix it.
●Be sure that the hooks of the side cover is fixed
in certainly. Otherwise water leakage may occur
and this causes short circuit or faults.
●The connecting cord should not touch to service
valve and pipes. (It becomes high temperature
in heating operation.)
●The naked part of the wire core should be 10 mm and fix
it to the terminal tightly. Then try to pull the individual wire
to check if the contact is tight. Improper insertion may
burn the terminal.
●Be sure to use only power cables approved from the
authorities in your country. For example in Germany: Cable
type: NYM 3x1.5mm2.
●Please refer to the installation manual for wire connection
to the terminals of the units. The cabling must meet the
standards of electrical installation.
●There is an AC voltage drop between the L and N terminals
if power is on. Therefore, before servicing, be sure to
remove the plug from the AC outlet or switch off the main
switch.
●Do not make any connection in the middle of the connecting
cable. It may cause the wire overheating, emit smoke and
fire.
Checking for the electric source
and the voltage range
●Before installation, the power source must be checked and
necessary wiring work must be completed. To make the wiring
capacity proper, use the wire gauges list below for the lead-in from
a pole transformer and for the wiring from a switch board of fuse
box to the main switch and outdoor unit in consideration of the
locked rotor current.
●
Investigate the power supply capacity and other
electrical conditions at the installation location.
Depending on the model of room air conditioner
to be installed, request the customer to make
arrangements for the necessary electrical work
etc.
The electrical work includes the wiring work
up the outdoor. In localities where electrical
conditions are poor, use of a voltage regulation
is recommended.
IMPORTANT
Cable length
up to 16m
up to 15m
up to 25m
Wire cross-section
1.6mm2
2.5mm2
4.0mm2
IMPORTANT
●THIS APPLIANCE
MUST BE EARTHED.
Procedures of Wiring
Wiring of The Outdoor Unit
●Please remove the side cover for wire connection.
!
WARNING
!
CONNECTION OF POWER CORD
●Please be careful when bending the copper pipe.
●Screw in manually while adjusting the center. After that, use of torque wrench to
tighten the connection.
WARNING
!
In case that power is supplied from Indoor Unit
How to Remove The Front Cover
BASE
DRAIN PIPE
●Please use exclusive
tool
CAUTION
!
In case of removing flare nut of an Indoor unit, first remove a nut
of small diameter side, or a seal cap of big diameter side will fly
out. Prevent water from entering into the piping when working.
When the meter reaches - 101KPa
(-76cmHg) during pumping, fully
tighten the shuttle.
Meter showing pressure
Closed
Manifold valve
Vacuum
pump
Valve
Charge hose
Valve
Vacuum pump
adapter
When pumping starts, slightly loosen the
flare nut to check of air sucked in. Then
tighten the flare nut.
Fuse Capacity
10A time delay fuse
After remove the screw
and cover, and put the
connecting cords and fix
the cover with screw.
1 Remove the front panel.
●Please remove and attach the front panel by both hands.
●After opening the front panel by both hands.
1Undo the right arm while pushing it inside.
2Slide the front panel to right as shown in figure. Then
remove while pulling it to front.
2 Remove the filters.
3 After removing two screws, pull the center of the front
cover towards you and release the claws.
4 Pull the side faces (lower sections) of the front cover
towards you as shown in the figure and remove the
cover.
How to Attach the Front Cover
1 Check that the drain pan is securely attached.
2 After installing the front cover onto the unit, hook three
claws at upper side of the cover securely. Then, push the
center of the front cover to lock the claws.
3 Tighten the two screws.
4 Install the filter.
5 Slide the shafts of the right and left arms on the washable
panel along the steps to insert the shafts into the holes till
they stop. After checking that the shafts are securely
inserted, close the panel.
CONDENSED WATER DISPOSAL OF OUTDOOR UNIT
There are holes on the base of Outdoor unit for condensed
water to exhaust.
In order to flow condensed water to the drain, the unit is installed on a
stand or a block so that the unit is 100mm above the ground as shown
figure. Join the drain pipe to one hole.
At first insert one portion of the hook to the base (Portion A), then pull the
drain pipe in the direction shown by the arrow while inserting the hook
into the base. After installation, check whether the drain pipe cling to the
base firmly.
When using in cold region, etc.
In cold region with severe cold climate and heavy snow, water
discharged from heat exchanger freeze on the base surface and this
may affect drainage. In such a region, remove bush on the bottom face
of outdoor unit for better drainage. When using drainpipe, consult our
dealer.
A
A
A
AA
Copper pipe
Trimming tool
A
Die Die
Copper pipe
Wrench Torque
wrench
Flare nut
Lo Hi
The body of
service valve
Cap of
valve core
Hexagonal
Wrench Key
Cap of valve head
Cap of valve head
L
N
DCBADCBA
Indoor Unit
Line Cord
AC 220-240V
Outdoor Unit
Connecting Cord
1.6 or 2.0
2.0
Sleeve of
protection pipe
Putty
Putty
Insulation material for pipe connection
Remote
Controller
Holder for
Remote Controller
Screw (2 pieces)
●Mount the outdoor unit on stable ground to prevent vibration and
increase of noise level.
●Decide the location for piping after sorting out the different types of
pipe available.
Procedure to remove the
cover of wiring terminals
●Remove the screw (1
piece).
●Hold the projected
part at the lower left
of the cover and push
the cover upwards to
remove it.
●To close the cover,
insert the upper part
of the cover into the
body of outdoor unit,
then be sure that the
hook below the cover
is plugged in before
screwing.
Hook
Please face this side (suction side)
of the unit to the wall
Please remove
the cover for
wire connection.
Outer
Diameter (mm)
6.35
9.52
12.70
For R410A tool
0.0 ~ 0.5mm
0.0 ~ 0.5mm
0.0 ~ 0.5mm
For R22 tool
A (mm)
1.0mm
1.0mm
1.0mm
Method to remove the low cover
●Pull the cover at 1 and 2 in the directions as shown by
arrows to remove the cover.
Drain Pipe
Bush
9
10
100 mm ABOVE
Wiring Of The Indoor Unit
●
For wire connection of the Indoor unit, you need to remove low
cover and front cover.
Method to remove front cover.
●
Refer to FINAL STAGE OF INSTALLATION How to Remove The“ –
Front Cover”.
Connection wire
is put under here
Side cover
A B C D
Connection wire Screw for earth line
Power line Control line
Indoor
Unit
Outdoor
Unit
GRN + YEL
GRN + YEL
Strip wires
25mm
25mm
10mm
30mm
10mm
30mm
10mm
10mm
70mm
10mm
10mm
35mm
Earth terminal
BA C D
Fuse Capacity
15A time delay fuse
For RAC-14CH8 only
●Please mount the Outdoor unit on stable ground to prevent vibration
and increase of noise level.
●Decide the location for piping after sorting out the different types of
pipe available.
●When removing side cover, please pull the handle after undoing the
hook by pulling it downward.
Please face this side (suction
side) of the unit to the wall.
Please remove side cover
when connecting the piping
and connecting cord.
Pull downward
BASE
DRAIN PIPE
CONDENSED WATER DISPOSAL OF OUTDOOR UNIT
There are holes on the base of Outdoor unit for condensed
water to exhaust.
In order to flow condensed water to the drain, the unit is installed on a
stand or a block so that the unit is 100mm above the ground as shown
figure. Join the drain pipe to one hole.
At first insert one portion of the hook to the base (Portion A), then pull
the drain pipe in the direction shown by the arrow while inserting the
hook into the base. After installation, check whether the drain pipe cling
to the base firmly.
When using in cold region, etc.
In cold region with severe cold climate and heavy snow, water
discharged from heat exchanger freeze on the base surface and this
may affect drainage. In such a region, remove bush on the bottom face
of outdoor unit for better drainage. When using drainpipe, consult our
dealer.
A
A
A
AA
DRAIN PIPE
BUSH
100 mm ABOVE
9
11
BUSH
12
For RAC-14CH8 only
For RAC-14CH8 only
For RAC-08/10CH8
Outer
dia.of pipe
6.35 (1/4")
9.52 (3/8")
12.7 (1/2")
6.35 (1/4")
9.52 (3/8")
12.7 (1/2")
Valve
head cap
Torque N·m
(kgf · cm)
13.7 – 18.6 (140 – 190)
34.3 – 44.1 (350 – 450)
44.1 – 53.9 (450 – 550)
19.6 – 24.5 (200 ~ 250)
19.6 – 24.5 (200 ~ 250)
29.4 – 34.3 (300 – 350)
12.3 – 15.7 (125 ~ 160)
Small dia. side
Large dia. side
Valve core cap
Small dia. side
Large dia. side
H
ITAC
HI
HITACHI
Step
Shaft
Hole
Especificaciones del producto
Marca: | Hitachi |
Categoría: | aire acondicionado |
Modelo: | RAS-08CH8B |
¿Necesitas ayuda?
Si necesitas ayuda con Hitachi RAS-08CH8B haz una pregunta a continuación y otros usuarios te responderán
aire acondicionado Hitachi Manuales
30 Septiembre 2024
23 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
16 Septiembre 2024
14 Septiembre 2024
14 Septiembre 2024
14 Septiembre 2024
14 Septiembre 2024
14 Septiembre 2024
aire acondicionado Manuales
- aire acondicionado Zibro
- aire acondicionado Candy
- aire acondicionado Electrolux
- aire acondicionado Samsung
- aire acondicionado LG
- aire acondicionado Bosch
- aire acondicionado AEG
- aire acondicionado Panasonic
- aire acondicionado BEKO
- aire acondicionado Delonghi
- aire acondicionado Daewoo
- aire acondicionado Grundig
- aire acondicionado Honeywell
- aire acondicionado Inventum
- aire acondicionado Siemens
- aire acondicionado Toshiba
- aire acondicionado Unold
- aire acondicionado Whirlpool
- aire acondicionado Vaillant
- aire acondicionado Adler
- aire acondicionado Akai
- aire acondicionado Apc
- aire acondicionado Amana
- aire acondicionado Argo
- aire acondicionado Arcelik
- aire acondicionado Bartscher
- aire acondicionado Tosot
- aire acondicionado Eurom
- aire acondicionado GE
- aire acondicionado Orbegozo
- aire acondicionado Ozito
- aire acondicionado Sharp
- aire acondicionado Klarstein
- aire acondicionado Gorenje
- aire acondicionado Nedis
- aire acondicionado Thomson
- aire acondicionado Korona
- aire acondicionado Black And Decker
- aire acondicionado Innoliving
- aire acondicionado Tristar
- aire acondicionado Domo
- aire acondicionado Trisa
- aire acondicionado Hotpoint-Ariston
- aire acondicionado Calor
- aire acondicionado Rowenta
- aire acondicionado Tomado
- aire acondicionado Livoo
- aire acondicionado Manta
- aire acondicionado SereneLife
- aire acondicionado Hisense
- aire acondicionado Hyundai
- aire acondicionado Vox
- aire acondicionado Westinghouse
- aire acondicionado Emerio
- aire acondicionado RCA
- aire acondicionado Clatronic
- aire acondicionado Hotpoint
- aire acondicionado Sencor
- aire acondicionado Midea
- aire acondicionado Blaupunkt
- aire acondicionado Mabe
- aire acondicionado Concept
- aire acondicionado Frigidaire
- aire acondicionado Svan
- aire acondicionado Logik
- aire acondicionado Danby
- aire acondicionado Anslut
- aire acondicionado Stirling
- aire acondicionado Daikin
- aire acondicionado Carson
- aire acondicionado Mesko
- aire acondicionado Profilo
- aire acondicionado Tripp Lite
- aire acondicionado Truma
- aire acondicionado Heinner
- aire acondicionado Sanyo
- aire acondicionado Eldom
- aire acondicionado Jocca
- aire acondicionado Einhell
- aire acondicionado Kenmore
- aire acondicionado Philco
- aire acondicionado TCL
- aire acondicionado Nabo
- aire acondicionado Guzzanti
- aire acondicionado Defy
- aire acondicionado Infiniton
- aire acondicionado Mitsubishi
- aire acondicionado Dometic
- aire acondicionado Aspes
- aire acondicionado Dimplex
- aire acondicionado DCG
- aire acondicionado Emerson
- aire acondicionado White Knight
- aire acondicionado Suntec
- aire acondicionado Profile
- aire acondicionado Orima
- aire acondicionado Haier
- aire acondicionado Gree
- aire acondicionado Evolar
- aire acondicionado Elba
- aire acondicionado Proline
- aire acondicionado Royal Sovereign
- aire acondicionado Corberó
- aire acondicionado Zelmer
- aire acondicionado Meaco
- aire acondicionado Fujitsu
- aire acondicionado Be Quiet!
- aire acondicionado Kelvinator
- aire acondicionado Element
- aire acondicionado Malmbergs
- aire acondicionado Everglades
- aire acondicionado Heylo
- aire acondicionado Insignia
- aire acondicionado Daitsu
- aire acondicionado Sanus
- aire acondicionado Milectric
- aire acondicionado Wilfa
- aire acondicionado Carrier
- aire acondicionado Olimpia Splendid
- aire acondicionado Trotec
- aire acondicionado Saunier Duval
- aire acondicionado Camry
- aire acondicionado Qlima
- aire acondicionado Alpatec
- aire acondicionado Jocel
- aire acondicionado Comfee
- aire acondicionado Godrej
- aire acondicionado Sauber
- aire acondicionado Maiko
- aire acondicionado MPM
- aire acondicionado Tectro
- aire acondicionado Rotel
- aire acondicionado Becken
- aire acondicionado Bavaria
- aire acondicionado Essentiel B
- aire acondicionado Equation
- aire acondicionado Vivax
- aire acondicionado Edy
- aire acondicionado HTW
- aire acondicionado Maxicool
- aire acondicionado Fuave
- aire acondicionado KDK
- aire acondicionado Dantherm
- aire acondicionado Thermex
- aire acondicionado Bimar
- aire acondicionado HQ
- aire acondicionado Be Cool
- aire acondicionado Master
- aire acondicionado MundoClima
- aire acondicionado Argoclima
- aire acondicionado Baxi
- aire acondicionado Proklima
- aire acondicionado Sonnenkonig
- aire acondicionado Lavorwash
- aire acondicionado Climadiff
- aire acondicionado Home Electric
- aire acondicionado REMKO
- aire acondicionado Fairland
- aire acondicionado Toyotomi
- aire acondicionado Just Fire
- aire acondicionado Avidsen
- aire acondicionado Teco
- aire acondicionado Furrion
- aire acondicionado Cecotec
- aire acondicionado Iceberg
- aire acondicionado Livington
- aire acondicionado Whynter
- aire acondicionado Chigo
- aire acondicionado Firstline
- aire acondicionado Holland Electro
- aire acondicionado Evapolar
- aire acondicionado Orava
- aire acondicionado EcoFlow
- aire acondicionado Duracraft
- aire acondicionado Khind
- aire acondicionado Fronius
- aire acondicionado NewAir
- aire acondicionado Kogan
- aire acondicionado ActronAir
- aire acondicionado Klimaire
- aire acondicionado SEEGER
- aire acondicionado LERAN
- aire acondicionado General Electric
- aire acondicionado Mistral
- aire acondicionado Friedrich
- aire acondicionado Simplicity
- aire acondicionado Starlyf
- aire acondicionado Moa
- aire acondicionado Fuji Electric
- aire acondicionado Kibernetik
- aire acondicionado Prem-i-air
- aire acondicionado Céliera
- aire acondicionado Bodin
- aire acondicionado Brivis
- aire acondicionado MRCOOL
- aire acondicionado B-Air
- aire acondicionado Rinnai
- aire acondicionado GoldAir
- aire acondicionado Ravanson
- aire acondicionado Create
- aire acondicionado Daizuki
- aire acondicionado Bonaire
- aire acondicionado Woods
- aire acondicionado Evapcool
- aire acondicionado Protector
- aire acondicionado Krone
- aire acondicionado IFB
- aire acondicionado Artrom
- aire acondicionado Coolix
- aire acondicionado Heat Controller
- aire acondicionado Luma Comfort
- aire acondicionado Norpole
- aire acondicionado Kaco
- aire acondicionado Omega Altise
- aire acondicionado Goodwe
- aire acondicionado Swegon
- aire acondicionado InAlto
- aire acondicionado JHS
- aire acondicionado FREONIC
- aire acondicionado ARCTIC WIND
- aire acondicionado SHE
- aire acondicionado Electroline
- aire acondicionado BLUEPALM
- aire acondicionado KuulAire
- aire acondicionado Keystone
- aire acondicionado Cool-Space
- aire acondicionado BOSFOR
- aire acondicionado Aconatic
- aire acondicionado AireMax
- aire acondicionado VänEE
- aire acondicionado Mayer
- aire acondicionado Perfect Aire
- aire acondicionado Koldfront
- aire acondicionado Yamazen
Últimos aire acondicionado Manuales
27 Octubre 2024
27 Octubre 2024
27 Octubre 2024
27 Octubre 2024
27 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
25 Octubre 2024