Honeywell Control Systems Ltd.
Arlington Business Park
Bracknell, Berkshire RG12 1EB
User Help Line: 01344 656511
USER GUIDE
What is a Programmable Thermostat?
The Honeywell CM61 is a programmable thermostat which controls your
heating system so that you can have comfortable temperatures when you
are at home and energy savings when you are away.
It is important to understand that the CM61 is not a traditional “ON/OFF”
controller but a “HI / LOW” temperature controller.
This means that to program the heating to go ‘OFF’ at a particular time a
lower (setback) temperature setpoint is entered which you would choose
to protect you and your home.
What will the CM61 Programmable Thermostat do
for me?
Attractive slim styling makes it ideal for location in any suitable
room in your home.
Display Backlight illuminates the display when a key is pressed for
easier viewing in low light conditions.
let you set 6 6 daily independent temperature levels any
temperatures from 5 to 30°C to match your daily lifestyle.
Holiday button saves energy by letting you reduce the temperature
for 1 to 99 days while you are on holiday, returning to normal operation
on the day you return.
Memory holds the user program indenitely so that it is never lost
even if you take the batteries out.
Outside Temperature Sensor (optional accessory) can be tted to
the CM61 to display the outside temperature.
Remote Temperature Sensor (optional accessory) can be tted to
the CM61 to control the temperature from another room.
Optimum Start option is a program which ensures that the optimum
temperature conditions are achieved at the required times as
described below (not available on T6661B1040).
What is Optimum Start?
Optimum Start is an Energy Efciency Feature that adjusts the start time
of your heating system depending upon how cold it is.
On cold days your Heating will be started earlier to ensure that your home
is warm when you get up and on warmer days the heating system will be
started later to save energy.
So, if the Optimum Start Feature is used, the time / temperature settings
which are entered into the CM61 are when you want to be warm by and
not when you want the heating to start. (not available on T6661B1040)
Comfort Solutions
What if something happens to my heating system? How can I check that the CM61 is working?
See the troubleshooting guide below. If you need assistance after this, call your installer. The CM61 should only be opened or removed by a qualied profes-
sional to prevent possible injury from electric shock.
www.honeywelluk.com
42010821-003 R1
CM61
Programmable
Thermostat
Warning.
This product and its associated documentation and packaging are protected by various intellectual property rights belonging to Honeywell Inc and its
subsidiaries and existing under the laws of the UK and other countries. These intellectual and property rights may include patent applications, registered
designs, unregistered designs, registered trade marks, unregistered trade marks and copyrights and also include the following UK registration rights:
UK patent application number 98062207.8
UK registered design numbers 2073334, 2073340 and 2073343.
Remedy
Check batteries are in the battery compartment and that the
paper tab has been pulled out
Check that the batteries have been installed in the correct
orientation.
Replace batteries
Remove battery cartridge and re-insert
Change the batteries as described previously
Check that there is power to the system
Press TEMP
to increase the temperature a few degrees
above the current room temperature. The heating should come
on after a few seconds.
Call installer to check electrical connection between the CM61
and the boiler
Call installer
Call installer
Remove battery cartridge and re-insert. If the symbol
does not clear itself in a few minutes call the installer
Call your installer to arrange a maintenance visit.
The CM61 and heating system will continue to operate as
normal.
Possible Cause
No batteries
Battery orientation
Exhausted batteries
Incorrect battery cartridge insertion
Batteries need replacing
No power to system
Program does not call for heat
CM61 not connected to boiler properly
CM61 not set correctly for your system
CM61 not set correctly for your system
Fault in the CM61
Your installer has set a scheduled
maintenance alert period on your CM61 as
a recommendation that your heating system
should receive a routine inspection.
Symptom
Blank Display
Display shows flashing symbol
Display works but heating does not
switch on
Heating switches ON/OFF too slowly
or too quickly
Temperature swings between too hot
and too cold
Display shows
symbol
Display shows the word 'SERVICE'
Trouble Shooting Guide
How can I switch the CM61 off?
Press the button. The unit has an intelligent built-in frost protection OFF
feature, so that if the temperature falls below 5°C, it will automatically
switch the heating on.
How do change the batteries?
With no other accessories tted and for applications other than electric
heating, the batteries should last about 4 years.
When the batteries need replacing, a ashing symbol will be
displayed.
To change the batteries:
1. Lift up the front ap to reveal the battery compartment. Open the
battery compartment by inserting a coin underneath the bottom right
edge of the ap and lift out.
2. Replace the used batteries with 2 new AA LR6 Alkaline Batteries and
push the battery compartment rmly back into the front of the unit.
RESPECT YOUR ENVIRONMENT!
Take care to dispose of used batteries carefully.
NOTE: If you take more than one minute to change the batteries the clock
may need to be reset - see How do I adjust the time?
Can I use my CM61 to control my air-conditioning
system?
Yes. Please refer to your installer for more information.
What does 'SERVICE' on the display of my CM61
mean (optional)?
NOTE:
This option only works if activated by your installer.
The ' ' indicator is displayed at set intervals as a reminder that SERVICE
your heating system requires a routine check. Please call your installer
to arrange a maintenance visit.
The symbol will remain on the display of the CM61 until it is either reset
or disabled by your installer. The CM61 and heating system will continue
to operate as normal.
How do I set the time?
The time can be set with the CM61 in the AUTO MAN , or operating OFF
modes. Press
or +
-
until the correct time is displayed. Each button
press will change the time by one minute. Holding the button down for a
few seconds will change the time slowly at rst, then quickly. Make sure
AM or PM is correct.
How do I get started with the factory default tem-
perature program?
Press the AUTO button. The CM61 will now control your heating using
the built-in temperature program:-
3. Press TEMP
or
to adjust the rst temperature level. Holding
the button down will change the temperature quickly. The temperature
can be set in 0.5°C steps from 5°C to 30°C.
4. Press to display the second temperature level and time PROG 2
levels. Set these by pressing
or +
-
and TEMP
or
.
5. The remaining temperature changes can be displayed by pressing
PROG 3 4 5 6 buttons , , and and adjusted by using
or +
-
and
TEMP
or
. (If you don’t want to use all the temperature change
times 2, 3, 4, 5 or 6 refer to the section “What if I don’t want to use
all 6 temperature change times?”).
6. Press AUTO when you have completed your programming, The CM61
will now control the room temperature to match your program.
What if I don’t want to use all 6 temperature
change times?
Although the CM61 has up to 6 temperature / time changes available
(PROG 1 – 6), any unused settings may be deleted by holding down the
appropriate button ( ) for 2 seconds.PROG 2 – 6
To reinstate any deleted setting hold down the button again for 2
seconds.
Can I change the programmed temperature for a
short time?
When the CM61 is in mode (display will show “AUTO”) the AUTO
temperature can be adjusted temporarily by pressing TEMP
or
. The temperature will return to the program at the next temperature
change time.
How do I check the programmed temperature?
In normal operation the temperature displayed is the actual room
temperature. To check the programmed temperature press
and the
display will show the programmed temperature with the two small
arrows.
How do I set one temperature for the whole day?
To operate as a simple thermostat with one temperature throughout the
day, press . Adjust the manual temperature by pressing MAN
TEMP
or
. The manual temperature can be set anywhere from 5°C to 30°C
in 0.5°C steps.
I am going on holiday for a few days. How do I
save energy but ensure that the house is warm
when I return?
1. Make sure the CM61 is in AUTO MAN or mode.
2. Press (HOLIDAY) to display the holiday days counter and
temperature.
3. Press
or +
-
to set the holiday time (1 - 99 days).
4. Press TEMP
or
to set the holiday temperature (5°C - 30°C).
The unit will control to the new temperature for the set number of days
holiday. At midnight the holiday counter will be reduced by one until the
selected number of days have passed. The unit will then return to normal
control as set by the or MAN AUTO button.
To cancel the HOLIDAY setting, press the button a second time.
CM61 Controls/Display Layout
The diagram below details the key button functions and display
information.
PM
What other accessories can I buy that work with
the CM61?
Honeywell provides other accessories and “Add-On” modules that can
be used with your CM61, ask your installer for details :
1. Automatic Time Setting (ATS) “Add-On” Module *
The ATS module picks up a daily time signal from a transmitter in Central
Europe and corrects the time on the CM61 display. So:
• You never need to set or adjust the time
• There is no need to adjust the unit by -/+ 1 hour in summer / winter
since the unit does this automatically
• Your CM61 is the most accurate clock in your home, so you can use
this information to set-up all your other clocks.
* Not available in all Geographic Regions depending on transmitter range
and home location.
2. Outside Temperature Sensor Accessory
The Outside Temperature Sensor accessory can be tted to your CM61
to display the outside temperature. By pressing the
twice, the CM61
displays the external temperature.
3. Remote Temperature Sensor Accessory
The Remote Temperature Sensor accessory can be tted to your CM61
to control the temperature of another room where it is inconvenient to
locate the CM61 e.g. commercial premises where the public may adjust
buttons.
Daily
Program 1 2 3 4 5 6
Time 6:30 8:00 12:00 2:00 6:00 10:30
Temperature 21°C 18°C 21°C 18°C 21°C 16°C
1 2 3 4 5 6
Battery Low
Indicator
Time Display Burner on
Indicator
Temperature
Change Buttons
= increase
= decrease
Information
Enquiry
Button
Temperature
Display
Holiday ButtonOff Button
Manual Function
Button
Battery
Compartment
Time
Change
Buttons
Program
Buttons
Automatic
Function
Button
TEMP
AUTO MAN OFF
1 2 3 4 5 6
PROG
EXT
CM61 Display Backlight
The CM61 has a backlit display that
will illuminate when a button is pressed
for easier viewing of the display in low light conditions. After the last button
press the backlight will remain on for 7 seconds.
SERVICE
How do I set my own daily temperature
program?
1. Press PROG 1. The rst temperature change time and temperature
level will ash to indicate they can be changed. (the two small
arrows are displayed only when the programmed temperature level
is shown).
2. Press or +
-
to adjust the rst temperature change time. Holding
the button down will change the time quickly. The change time can be
set in 10 minute steps from 03:00 in the morning. The change time
can be adjusted up to 02:50 on the next morning, so you can maintain
the evening temperature after midnight.
(Note: If you attempt to move a change time past the next change
time, both times will be moved).
3. Press TEMP
or
to adjust the rst temperature level. Holding
the button down will change the temperature quickly. The temperature
can be set in 0.5°C steps from 5°C to 30°C.
1 2 3 4 5 6
Especificaciones del producto
Marca: | Honeywell |
Categoría: | Termostato |
Modelo: | Chronotherm CM61 |
¿Necesitas ayuda?
Si necesitas ayuda con Honeywell Chronotherm CM61 haz una pregunta a continuación y otros usuarios te responderán
Termostato Honeywell Manuales
22 Octubre 2024
4 Octubre 2024
4 Octubre 2024
2 Octubre 2024
29 Septiembre 2024
29 Septiembre 2024
27 Septiembre 2024
23 Septiembre 2024
22 Septiembre 2024
17 Septiembre 2024
Termostato Manuales
- Termostato ATAG
- Termostato Bosch
- Termostato AEG
- Termostato Panasonic
- Termostato Junkers
- Termostato Nefit
- Termostato Remeha
- Termostato Siemens
- Termostato Vaillant
- Termostato Ambiano
- Termostato Amfra
- Termostato Google
- Termostato Renkforce
- Termostato Itho
- Termostato De Dietrich
- Termostato Elro
- Termostato EMOS
- Termostato Truma
- Termostato Intergas
- Termostato Schneider
- Termostato Hama
- Termostato Fenix
- Termostato Theben
- Termostato Elektrobock
- Termostato Devi
- Termostato Stiebel Eltron
- Termostato Buderus
- Termostato Dimplex
- Termostato Vemer
- Termostato Profile
- Termostato Magnum
- Termostato Horstmann
- Termostato Salus
- Termostato Tylö
- Termostato Somfy
- Termostato Grohe
- Termostato Oventrop
- Termostato King
- Termostato Technoline
- Termostato Devolo
- Termostato Arnold Rak
- Termostato Heatmiser
- Termostato Viessmann
- Termostato Carrier
- Termostato Nest
- Termostato Itho-Daalderop
- Termostato Hive
- Termostato Danfoss
- Termostato Saunier Duval
- Termostato Netatmo
- Termostato Seitron
- Termostato Sygonix
- Termostato Tado
- Termostato Hunter
- Termostato Busch-Jaeger
- Termostato Bulex
- Termostato AWB
- Termostato Finder
- Termostato Xavax
- Termostato Fantini Cosmi
- Termostato Delta Dore
- Termostato Orbis
- Termostato EBERLE
- Termostato Grasslin
- Termostato Gira
- Termostato Jung
- Termostato Wolf
- Termostato HQ
- Termostato Max
- Termostato Frico
- Termostato Vasco
- Termostato Radson
- Termostato Nobo
- Termostato Baxi
- Termostato EQ3
- Termostato Homematic IP
- Termostato Weishaupt
- Termostato REMKO
- Termostato ICY
- Termostato Computherm
- Termostato Avidsen
- Termostato Crestron
- Termostato ORNO
- Termostato Berker
- Termostato Drayton
- Termostato Heatit
- Termostato Watts
- Termostato Etherma
- Termostato Eurotronic
- Termostato Oregon Scientific
- Termostato Muller
- Termostato Econo-Heat
- Termostato PECO
- Termostato H-Tronic
- Termostato Intertechno
- Termostato EQ-3
- Termostato Tru Components
- Termostato Emko
- Termostato Easy Timer
- Termostato Maico
- Termostato HomePilot
- Termostato THERMAFLEX
- Termostato Johnson Control
- Termostato Drayton Erie
- Termostato Qubino
- Termostato STI
- Termostato ELKO
- Termostato TrickleStar
- Termostato Gewiss
- Termostato Sinustec
- Termostato Rose LM
- Termostato Otio
- Termostato MundoControl
- Termostato Enda
- Termostato Bearware
- Termostato GENERAL Life
- Termostato Oreg
Últimos Termostato Manuales
27 Octubre 2024
27 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024