704492 / 00 10 / 2008
UK
Operating instructions
(Ex protection related part) for inductive sensors according to
EU directive 94/9/EC annex VIII (ATEX) group II, equipment category 3D/3G
2
Remarks for safe use in hazardous areas
Functions and features
Use in hazardous areas according to the classification
II 3D
(group II, category 3D, apparatus for dust atmosphere).
The requirements of the standards EN 61241-1 and EN 61241-0 are met.
Use in hazardous areas according to the classification
II 3G
(group II, category 3G, apparatus for gas atmosphere).
The requirements of the standard EN 60079-15 are met.
Marking (see unit or technical data sheet)
II 3D Ex tD A22 IP67 T80°C X Ta: 0°C...+60°C
II 3G Ex nA T6 X
Permissible operating temperature of the application (proper usage):
Ta: 0°C...+60°C
Installation / Set-up
The units must only be installed, connected and set up by qualified staff. The qualified staff
must have knowledge of protection classes, regulations and provisions for apparatus in
hazardous areas.
Check whether the classification (see "Marking" above and marking on the unit) is suitable
for the application.
Installation remarks / Installation
Adhere to the respective national regulations and provisions as well as the relevant
installation regulations.
Avoid electrostatic charging on plastic units and cables.
To avoid electrostatic charging clean the unit with a damp cloth only. Rubbing with non-
conductive materials must be strictly avoided.
To avoid electrostatic charging steps must be taken to ensure the equalisation of potential
of metal parts (plug housing, fixing elements, protective housing, etc.).
Do not mount the unit in the dust flow.
Avoid dust deposits on the units.
Protect the units and the cables efficiently against damage.
For the connections and the electrical technical data please see the unit marking or the
technical data sheet.
To avoid soiling, do not remove the connector cover until attaching the socket.
Avoid direct radiation with high UV components (sunlight). Mount the unit in a protected
place.
M12 plugs may only be opened or closed in a sufficiently clean environment.
3
UK
Special conditions for safe operation
The housing and housing parts made of plastic were tested in accordance with table 8 of
EN 60079-0 for group II and table 5 of EN 61241-0 for group II and for a low mechanical
risk with an impact energy of 4 joules.
Use sockets which are suited for hazardous areas, e.g. ifm sockets EVC**A with Ex
certificate (certificate number BVS 08 ATEX E 109 U).
Protect the sockets by tightening the hexagon coupling nut sufficiently according to the
requirements of the Ex protection related operating instructions of the socket.
Do not separate the connector when energized.
Apply a durable warning in suitable form close to the connector reading: "Do not separate
when energized" or use the enclosed label if you can ensure a durable marking.
Maintenance / Repair
The unit must not be modified nor can it be repaired. In case of a fault please contact the
manufacturer.
If required, the technical data sheets and EC declarations of conformity can be obtained
from the manufacturer (see cover sheet). Indicate the article number.