Operating instructions
Through-beam sensor
OJ50xx laser
704755 / 00 05 / 2010
UK
2
Contents
1 Preliminary note....................................................................................................3
1.1 Symbols used .................................................................................................3
2 Safety instructions ................................................................................................3
4 Installation ............................................................................................................4
4.1 Installation of the supplied mounting fixture ...................................................5
5 Electrical connection.............................................................................................6
6 Setup ....................................................................................................................6
7 Settings.................................................................................................................7
7.1 Setting of the sensitivity with stationary objects* ............................................7
7.2 Setting of the sensitivity with moving objects* ................................................8
7.3 Setting of the maximum sensitivity* ................................................................9
7.4 Electronic lock ................................................................................................9
7.5 Programming the output function* ..................................................................9
8 Operation ............................................................................................................10
9 Maintenance, repair and disposal.......................................................................10
3
UK
1 Preliminary note
1.1 Symbols used
Instruction
> Reaction, result
Cross-reference
Important note
Non-compliance can result in malfunctions or interference.
Information
Supplementary note.
2 Safety instructions
According to the cULus approval
Caution - Use of controls or adjustments or procedures other than those specified
herein may result in hazardous radiation exposure.
Visible laser light; CLASS 1 LASER PRODUCT.
IEC 60825-1 : 2007
Complies with 21 CFR 1040.10 except for deviations pursuant to Laser
Notice No. 50, dated June 2007.
Position of the product label Additional label
Beispiel OJ5016
6
5 Electrical connection
The unit must be connected by a qualified electrician.
The national and international regulations for the installation of electri-
cal equipment must be adhered to.
Voltage supply according to EN 50178.
Disconnect power.
Connect the unit as follows:
Receiver DC PNP Receiver DC NPN
L
L+
3
2
4
1
teach
L
L+
3
2
4
1
teach
Transmitter DC
1
3
L+
L
Programming of the output function by pushbutton or programming wire
(→ 7.5 Programming the output function).
6 Setup
The through-beam sensor is supplied ready to operate (plug & play) set at the
max. sensing range. This is sufficient if the through-beam sensor can operate with
maximum excess gain. The following setting procedures should only be necessary
in less straight-forward applications, for example if partly transparent objects must
be detected.
8
7.2 Setting of the sensitivity with moving objects*
1
Go into the programming mode of the unit.
Press about 2 s
until the red LED flashes.
The red LED goes out; the yellow and green LEDs flash alternately. >
The unit is in the programming mode. >
2
Allow objects to pass through the detection area during the measurement (about
1 s) (number of the objects between min. 8 Hz and max. switching frequency).
Press once.
The yellow and green LEDs go out for approx. 1 s, then flash again alternately. >
3
Allow objects to pass through the detection area during the measurement (about
1 s) (number of the objects between min. 8 Hz and max. switching frequency).
Press once.
The yellow and green LEDs go out for approx. 1 s. >
After approx. 3 s the green LED is on. >
The unit is in the operating mode. >
* The sensitivity can also be set in exactly the same way using the programming wire (pin 2 /
WH). To activate the functions the programming wire is connected to L+ (pin 1 / BN) for PNP
units or to L- (pin 3 / BU) for NPN units for the appropriate time. Feedback: If setting was not
successful via the programming wire, the output will switch for 2 s. The unit then passes into
the operating mode with the sensitivity being unchanged.