Operating instructions
Electronic pressure sensor
PL265x
706070/01 09/2011
UK
2
1 Preliminary note
1.1 Symbols used
Instruction
> Reaction, result
[…] Designation of buttons, switches or indications
Cross-reference
Important note
Non-compliance can result in malfunctions or interference.
Contents
1 Preliminary note 2 ...................................................................................................
1.1 Symbols used 2 ................................................................................................
2 Safety instructions 3 ...............................................................................................
3 Functions and features 4 ........................................................................................
3.1 Applications ...................................................................................................4
4 Function ...............................................................................................................5
4.1 Processing of the measured signals 5 ..............................................................
5 Installation............................................................................................................6
6 Electrical connection 7 ............................................................................................
7 Operation .............................................................................................................8
7.1 Cleaning of the filter cover 8 .............................................................................
8 Parameter setting 9 ................................................................................................
8.1 Adjustable parameters 9 ...................................................................................
9 Scale drawing 10 ....................................................................................................
10 Technical data 12 ..................................................................................................
10.1 Setting ranges 13 ...........................................................................................
3
UK
2 Safety instructions
• Read this ducument before installing the unit. Ensure that the product is suit-
able for your application without any restrictions.
• Non-adherence to the operating instructions or technical data can lead to
personal injury and/or damage to property.
• Inallapplicationscheckcomplianceoftheproductmaterials(→10Technical
data) with the media to be measured.
• Use in gases at pressures > 25 bar only after contacting the manufacturer ifm.
For the scope of validity cULus: The device shall be supplied from an isolating
transformer having a secondary Listed fuse rated as noted in the following table.
Overcurrent protection
Control-circuit wire size Maximum protective device rating
Ampere
AWG (mm2)
26 (0.13) 1
24 (0.20) 2
22 (0.32) 3
20 (0.52) 5
18 (0.82) 7
16 (1.3) 10
The Sensor shall be connected only by using any R/C (CYJV2) cord, having suit-
able ratings.