IFM UGT529 Manual de Usario

Lee a continuación 📖 el manual en español para IFM UGT529 (5 páginas) en la categoría No categorizado. Esta guía fue útil para 6 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/5
Operating instructions
Ultrasonic diffuse-reflection sensor
with IO-Link
UGT527
UGT528
UGT529
80268715 / 00 05 / 2018
UK
2
1 Preliminary note
1.1 Symbols used
Instructions
> Reaction, result
[…] Designation of keys, buttons or indications
Cross-reference
Important note
Non-compliance may result in malfunction or interference.
Information
Supplementary note.
2 Safety instructions
Read this document before setting up the product and keep it during the entire
service life.
The product must be suitable for the corresponding applications and
environmental conditions without any restrictions.
Only use the product for its intended purpose ( ).→ 3 Functions and features
If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property may occur.
The manufacturer assumes no liability or warranty for any consequences
caused by tampering with the product or incorrect use by the operator.
Installation, electrical connection, set-up, operation and maintenance of the
product must be carried out by qualified personnel authorised by the machine
operator.
Protect units and cables against damage.
3 Functions and features
Ultrasonic sensor for monitoring levels and detecting objects.
3
UK
4 Installation
1
3
2
Secure the unit to a bracket.
1/2: status LEDs 1/2 (yellow), setting aid
and output indication
3: echo LED (green), is on when object or
background is detected
Sound-absorbing surfaces have a negative effect on a reliable function.
Consider the dead zone (Technical data sheet):
No object detection in the dead zone.
For units with metal housing (according to UL 508):
Observe a minimum distance of 12.7 mm between the sensor and non-
insulated live parts.
For further information please refer to www.ifm.com
General information about installation and operation.
5 Electrical connection
Disconnect power.
Connect device (depending on the type selected):
BK: black
BN: brown
BU: blue
WH: white
BN
WH
BK
BU
4
1
3
2OUT2
L+
L
OUT1
• OUT1: switching output / IO-Link
• OUT2: switching output
colours to DIN EN 60947-5-2

Especificaciones del producto

Marca: IFM
Categoría: No categorizado
Modelo: UGT529

¿Necesitas ayuda?

Si necesitas ayuda con IFM UGT529 haz una pregunta a continuación y otros usuarios te responderán




No categorizado IFM Manuales

No categorizado Manuales

Últimos No categorizado Manuales