IFM VWV002 Manual de Usario

Lee a continuación 📖 el manual en español para IFM VWV002 (9 páginas) en la categoría No categorizado. Esta guía fue útil para 6 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/9
Operating instructions
Wireless vibration sensor
VW
80291663/00 09/2020
UK
2
1 Preliminary note
Technical data, approvals, accessories and further information at
www.ifm.com.
2 Safety instructions
Read this document before setting up the product and keep it during the entire
service life.
The product must be suitable for the corresponding applications and
environmental conditions without any restrictions.
Only use the product for its intended purpose (→ Functions and features).
If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property may occur.
The manufacturer assumes no liability or warranty for any consequences
caused by tampering with the product or incorrect use by the operator.
Installation, electrical connection, set-up, operation and maintenance of the
product must be carried out by qualified personnel authorised by the machine
operator.
The plant operator is responsible for the safety of the plant in which the device
is installed.
If the device is not used as intended by the manufacturer, the protection
supported by the device may be impaired.
Protect units and cables against damage.
Operation can affect the function of electronic devices that are not correctly
shielded. Disconnect the unit in the vicinity of medical equipment. Please
contact the manufacturer of the device in case of problems.
2.1 Interference with medical devices
The device emits radio waves that may interfere with the operation of electronic
devices in the vicinity, including pacemakers, hearing aids and defibrillators.
If you have a pacemaker or other implanted medical device, do not use the sensor
without first consulting your doctor or the manufacturer of your medical device.
Keep a safe distance between the device and your medical devices and refrain
from further use of the device if you observe permanent impairment of your
medical device.
3
UK
3 Symbols used
► Instruction
> Reaction, result
→ Cross-reference
Important note
Non-compliance may result in malfunction or interference.
Information
Supplementary note.
4 Functions and features
Condition monitoring on machines and installations (vibration and temperature)
The device transmits sensor data at pre-configured intervals by radio to a
gateway and from the gateway into the backend system.
In the backend, the sensor data is visualised and can be used to carry out
analyses, evaluations and create alarm rules.
Recommended temperature range -20...55° C.
The device must not be operated within a radius of 20 km around Ny-Ålesund,
Spitsbergen, Norway.
Operating temperatures outside this range will shorten battery life.
5 Product overview
Order number Description
VWV001 Measurement axis in Z direction
VWV002 Measurement axis in X, Y and Z direction
6 Function
The device has a radio interface on the basis of a 2.4 GHz ISM band and enables
access to process and diagnostic data (e.g. battery status) via the gateway.
The device offers the following functions if combined with suitable hardware and
software (e.g. moneo):
remote parameter setting of the device
transmission of measured values without wiring or loss of measured values

Especificaciones del producto

Marca: IFM
Categoría: No categorizado
Modelo: VWV002

¿Necesitas ayuda?

Si necesitas ayuda con IFM VWV002 haz una pregunta a continuación y otros usuarios te responderán




No categorizado IFM Manuales

No categorizado Manuales

Últimos No categorizado Manuales