JANDY JEP-R Manual de Usario
Lee a continuación 📖 el manual en español para JANDY JEP-R (60 páginas) en la categoría Pompa. Esta guía fue útil para 5 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/60

H0412200 Rev J
ENGLISH | FRAN AIS | ESPAÑOLÇ
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and
qualified in pool equipment by the jurisdiction in which the product will be installed where such state
or local requirements exist. The maintainer must be a professional with sufficient experience in pool
equipment installation and maintenance so that all of the instructions in this manual can be followed
exactly. Before installing this product, read and follow all warning notices and instructions that accompany
this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can
cause serious injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the
installation, operation and safe use of this product. This information should be given to
the owner/operator of this equipment.
INSTALLATION AND
OPERATION MANUAL
Jandy Pro Series
JEP-R
Variable-Speed Pump Digital Controller
For use with Jandy Pro Series Variable-Speed Pumps
For Indoor or Outdoor Installations

Table of Contents
DATE OF INSTALLATION
INSTALLER INFORMATION
INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER)
PUMP MODEL HORSEPOWER
FILTER MODEL SERIAL NUMBER
CONTROLLER MODEL SERIAL NUMBER
NOTES:
EQUIPMENT INFORMATION RECORD
Section 1. IMPORTANT
SAFETY INSTRUCTIONS 3 ...................
1.1 Safety Instructions 3 .............................................
1.2 Pool Pump Suction Entrapment Prevention
Guidelines 6 ..........................................................
Section 2. Installation of the
Digital Controller 7 ................................
2.1 Introduction ........................................................7
2.2 The Controller Panel 7 ..........................................
2.3 The Controller Components 7 ...............................
2.3.1 Additional materials 8 .....................................
2.4 Installation of the Backplate
onto an Electrical Box 8 ........................................
2.5 Installation of the Backplate
on a Flat Wall 8 .....................................................
2.6 Connection to Jandy® Pro Series
variable-speed Pump 8 .........................................
2.7 Variable Speed Pump Switch Settings 9 ..............
2.8 Connection to Remote Contacts 9 ........................
2.9 Remote Operation 10 .............................................
2.10 Remote Closure 4 Behavior 10 ...............................
2.11 Remote Closure 4 Application
- Booster Pump Support 10 ....................................
Section 3. User Operation of the Variable-Speed
Controller ............................................ 11
3.1 The Controller Interface .....................................11
3.2 Basic Functions .................................................11
3.3 OFF Mode ..........................................................11
3.4 RUN Mode .........................................................11
3.5 Manual Start and Stop 12 .......................................
3.6 Pump Speed Setting 12 ..........................................
3.7 Timeclock Setup and Operation.........................12
3.8 Keypad Lock 13 ......................................................
Section 4. Service Setup Options 13 .......................
4.1 Entering Service Setup 13 ......................................
4.2 Minimum and Maximum Pump Speeds 13 .............
4.3 Load Defaults 14 .....................................................
4.4 Last Fault 14 ...........................................................
4.5 Priming Speed and Duration 14 ..............................
4.6 eStar Speed 15 .......................................................
4.7 Pump Freeze Protect Operation 15 ........................
4.8 Selecting Pump Type .........................................15
4.9 Display Power Usage 15 ........................................
Section 5. User Set Up Options 16 ...........................
5.1 Setting Time-of-Day ...........................................16
5.2 Labeling Speeds 16 ................................................
5.3 General Labels 16 ..................................................
5.4 Custom Labels 16 ...................................................
5.5 Display Light Control 16 ..........................................
5.6 Language Selection 17 ...........................................
5.7 Run Duration (Speeds 3 and 4 Only) 17 .................
5.8 Password Protect 17 ...............................................
Section 6. Menu Flow Chart 18 .................................
PAGE 2
ENGLISH JEP-R Variable-Speed Pump Controller | Installation Manual

Section 1. IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
1.1 Safety Instructions
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the
following:
WARNING
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN RESULT IN SERIOUS
INJURY OR DEATH. Do not block pump suction, as this can cause severe injury or death. Do not
use this pump for wading pools, shallow pools, or spas containing bottom drains, unless the pump is
connected to at least two (2) functioning suction outlets. Drain covers must be certified to the latest
published edition of ANSI®/ASME® A112.19.8 or its successor standard, ANSI/APSP-16.
WARNING
To reduce the risk of injury, do not permit children to use this product.
WARNING
To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide,
or full flow) valve position with the pump running.
WARNING
To reduce the risk of injury, do not remove the suction fittings of your spa or hot tub. Never operate a spa or hot tub if
the suction fittings are broken or missing. Never replace a suction fitting with one rated less than the flow rate marked
on the equipment assembly.
WARNING
Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when the internal temperature
of the body reaches a level several degrees above the normal body temperature of 98.6°F (37°C). The symptoms
of hyperthermia include dizziness, fainting, drowsiness, lethargy, and an increase in the internal temperature of
the body. The effects of hyperthermia include: 1) unawareness of impending danger; 2) failure to perceive heat;
3) failure to recognize the need to exit spa; 4) physical inability to exit spa; 5) fetal damage in pregnant women;
6) unconsciousness resulting in a danger of drowning.
WARNING
To Reduce the Risk of Injury -
a The water in a spa should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and 104°F )
(40°C) are considered safe for a healthy adult. Lower water temperatures are recommended for young children
and when spa use exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for causing fetal damage during the early months of
pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to 100°F (38°C).
c) Before entering a spa or hot tub, the user should measure the water temperature with an accurate thermometer
since the tolerance of water temperature-regulating devices varies.
d) The use of alcohol, drugs, or medication before or during spa or hot tub use may lead to unconsciousness with
the possibility of drowning.
e) Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system
problems, or diabetes should consult a physician before using a spa.
f) Persons using medication should consult a physician before using a spa or hot tub since some medication may
induce drowsiness while other medication may affect heart rate, blood pressure, and circulation.
PAGE 3
ENGLISH
JEP-R Variable-Speed Pump Controller | Installation Manual
Especificaciones del producto
Marca: | JANDY |
Categoría: | Pompa |
Modelo: | JEP-R |
Color del producto: | Zwart |
Peso.: | 2800 g |
Manual de usuario: | Ja |
Fuente de alimentación: | 100-240V 50/60Hz, 0, 8A |
Tecnología de conectividad: | Bedraad |
red LAN: | Ja |
Tarjetas de memoria compatibles: | Memory Stick (MS), MMC, MS PRO, SD, SDHC |
Resolución de grabación: | 720 x 480 Pixels |
Número de puertos USB 2.0: | 3 |
Número de puertos HDMI: | 1 |
Número de puertos Ethernet LAN (RJ-45): | 1 |
Certificación: | CE, FCC, RoHs |
Formato de señal analógica: | NTSC, PAL |
Formato de imagen soportado: | BMP, GIF, JPG, PNG, TIF |
Versión HDMI: | 1.3 |
Sintonizador de TV integrado: | Ja |
Cambio de hora: | Nee |
Sistemas operativos compatibles: | Windows 2000 / XP / VISTA / 7\nMac OS X\nLinux |
Velocidad de transferencia de datos de LAN inalámbrica (máx.): | 300 Mbit/s |
Número de puertos SCART: | 1 |
Formatos de subtítulos admitidos: | ASS, SMI, SRT, SSA, SUB |
Capacidad del disco duro: | 1000 GB |
Vídeo de grupo de componentes (YPbPr/YCbCr): | 1 |
tipo de sintonizador de televisión: | DVB-T |
Dimensiones (Ancho x Fondo x Alto): | 342 x 207 x 55 mm |
LED de enlace/actuación: | Ja |
Tamaño del disco duro: | 3.5 " |
Ratio de transferencia: | 480 Mbit/s |
Wifi.: | Ja |
CD ROM: | Ja |
¿Necesitas ayuda?
Si necesitas ayuda con JANDY JEP-R haz una pregunta a continuación y otros usuarios te responderán
Pompa JANDY Manuales

27 Octubre 2024

2 Septiembre 2024

2 Septiembre 2024

2 Septiembre 2024

2 Septiembre 2024

2 Septiembre 2024

31 Agosto 2024

31 Agosto 2024

31 Agosto 2024

31 Agosto 2024
Pompa Manuales
- Pompa Karcher
- Pompa Nefit
- Pompa Siemens
- Pompa Vaillant
- Pompa Al-ko
- Pompa Eurom
- Pompa Generac
- Pompa Ozito
- Pompa Gude
- Pompa Silvercrest
- Pompa Makita
- Pompa Bestway
- Pompa Vonroc
- Pompa Crivit
- Pompa Hyundai
- Pompa Ryobi
- Pompa Sicce
- Pompa Outwell
- Pompa Metabo
- Pompa Worx
- Pompa Milwaukee
- Pompa Tacklife
- Pompa Hazet
- Pompa Einhell
- Pompa SKS
- Pompa Gardena
- Pompa Hayward
- Pompa Eheim
- Pompa Nibe
- Pompa Melinera
- Pompa Oase
- Pompa GRE
- Pompa Powerplus
- Pompa Sanibroyeur
- Pompa Danfoss
- Pompa Michelin
- Pompa Scheppach
- Pompa Zodiac
- Pompa Powerfix
- Pompa Topeak
- Pompa Hozelock
- Pompa Lezyne
- Pompa Fluke
- Pompa For_Q
- Pompa Simpson
- Pompa Fieldmann
- Pompa WHALE
- Pompa Fluval
- Pompa Fuxtec
- Pompa Astralpool
- Pompa Abac
- Pompa Waldbeck
- Pompa Cannondale
- Pompa Coleman
- Pompa Maruyama
- Pompa Jabsco
- Pompa Toolcraft
- Pompa Eufab
- Pompa Pontec
- Pompa Westfalia
- Pompa ESPA
- Pompa POLARIS
- Pompa Osram
- Pompa Park Tool
- Pompa Velda
- Pompa Vivaria
- Pompa Plantiflor
- Pompa Little Giant
- Pompa Panduit
- Pompa Wetelux
- Pompa Anova
- Pompa DAB
- Pompa Esotec
- Pompa Wayne
- Pompa T.I.P.
- Pompa Rule
- Pompa Neptun
- Pompa Elpumps
- Pompa Hollex
- Pompa B-Air
- Pompa Baracuda
- Pompa Lifan
- Pompa Enermax
- Pompa Monzana
- Pompa Liberty Pumps
- Pompa BluGarda
- Pompa Alpha Tools
- Pompa Grundfos
- Pompa Madimack
- Pompa Sauermann
- Pompa Eco-Flo
- Pompa Nowax
- Pompa Zoeller
- Pompa Superior Pump
- Pompa SHURflo
- Pompa EvoHeat
- Pompa MSW
- Pompa OKAY
- Pompa FIAP
- Pompa Barwig
- Pompa Ribimex
- Pompa Ebara
- Pompa Perlick
- Pompa Basement Watchdog
- Pompa Ergotools Pattfield
- Pompa Zéfal
- Pompa Zehnder Pumpen
- Pompa Comet
- Pompa SANDPIPER
- Pompa Heissner
- Pompa Blackburn
- Pompa OSIP
- Pompa Franklin Electric
Últimos Pompa Manuales

26 Octubre 2024

26 Octubre 2024

26 Octubre 2024

15 Octubre 2024

15 Octubre 2024

15 Octubre 2024

15 Octubre 2024

15 Octubre 2024

15 Octubre 2024

12 Octubre 2024