Centre plate with timer function "standard"
Blinds Management
Centre plate with timer function "standard"
Art. No. : .. 5232 ST ..
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1: Device components
(1) Venetian blind control
(2) Frame
(3) Cover
1/5
32537613
J:0082537613 21.05.2014
Figure 2: Display and buttons
(4) Current weekday
(5) Operating mode: Manual or Automatic
(6) Current time of day
(7) Buttons
3 Function
Intended use
- Manual and time-controlled operation of electrically-driven Venetian blinds, shutters and
awnings
- Operation on control of the Venetian blind control system
Product characteristics
- Each Up and Down travelling time can be saved for weekdays and for the weekend
- Travelling times programmed at the factory
- Current time of day can be saved as travelling time
- Automatic and manual operation
- Operation via 4 buttons
- Indication of the current time
- Programming without flush-mounted insert possible
- Power reserve > 6 hours
Behaviour after a mains voltage failure
Voltage failure less than 6 hours
- Time and switching times are retained
- Missed travelling times are not performed later
Voltage failure greater than 6 hours
- Time flashes and the manual operating mode is active.
- Time and weekday must be set again
- The travelling times are reset to default setting
Travelling times with the default setting
Movement direction Weekdays Time
up Mo - Fr 7:00
Down Mo - Fr 20:00
2/5
32537613
J:0082537613 21.05.2014
Blinds Management
Centre plate with timer function "standard"
up Sa - Su 9:00
Down Sa - Su 20:00
4 Operation
Moving the Venetian blind
oPress or button between one and three seconds.n o
The Venetian blind moves in the desired direction to the end position or stops when the
button is pressed again.
iIn automatic operation, the Up and Down travelling time programmed for this day is
displayed for about 4 seconds during manual operation.
Adjusting the slats
oPress the or button for less than one second.n o
The slat position changes in the desired direction for as long as the button is pressed.
Changing between automatic and manual operation
oPress button for longer than 1 second.AUTO/MAN
The cover changes the operating mode.
iIn manual operation, no automatic moves are executed.
Setting time and programming travelling times
Figure 3: Programming steps
After the start of programming, the following steps are passed through in succession (figure 3).
A: Enter current time and day.
B: Enter Up and Down travelling time for Mon-Fri.
C: Enter up and down travelling time for Sat-Sun.
oPress the button for longer than 2 seconds.PROG
The programming is started. The value to be changed flashes.
oPress or button to change times. n o
oPress button to save the entered value and to recall the next value (figure 3).Prog
iA long press when setting the minutes causes an adjustment in steps of 5.
iTo cancel the programming, press the button for longer than 2 seconds or do notPROG
press any button for 2 minutes.
3/5
32537613
J:0082537613 21.05.2014
Blinds Management
Centre plate with timer function "standard"

Especificaciones del producto

Marca: Jung
Categoría: No categorizado
Modelo: ES5232ST
Color del producto: Zwart
Peso.: 948 g
Ancho: 215 mm
Profundidad: 165 mm
Altura: 350 mm
Amable: Buitengebruik muurverlichting
Material de la carcasa: Aluminium
Número de lámparas: 1 gloeilamp(en)
Tipo de lámpara: Witgloeiend
Lámpara de encendido: - W
Código de seguridad internacional (IP): IP44
Tipo de fuente de energía: AC
Cantidad por paquete: - stuk(s)
Funciones de seguridad: Nee
Tipo de ajuste/pie: E27
Controlado remotamente: Nee
Los activos totales: 60 W
clase de protección: I
Modo autónomo: Nee
Regulador de intensidad: Nee
voltaje-de-entrada-de-CA: 220 - 240 V
Frecuencia-de-entrada-de-CA: 50 - 60 Hz
Lámpara compatible con clases de eficiencia energética (antigua): A, A+, A++, B,C, D,E
Glaskleur: Transparant
Adecuado-para-uso-en-exteriores: Patio

¿Necesitas ayuda?

Si necesitas ayuda con Jung ES5232ST haz una pregunta a continuación y otros usuarios te responderán




No categorizado Jung Manuales

No categorizado Manuales

Últimos No categorizado Manuales