System Manual
In-Home bus: Audio
Issue 2016
2
Contents
8 Supplementary functions
Switching and control functions 79
Door release actuation 80
Parallel door call 82
Storey call parallel switching 86
Supplementary contact, radio
chime, pilfer safeguard 87
Staircase light/Outside light 88
9 Servicing
Restart, exchange,
operating mode 89
LE 91D displays BNG650-
Measured values 92
10 Glossary, Index 93
1 In-Home bus: Audio
System description 3
2 Siedle Systemtechnik
Jung indoor stations 3
3 Safety remarks
Danger 3
4 tion, conductor Congura
lengths
User assignment 4
Single line system 5
Single line system with -
intercom functions 7
Multiple line system 8
5 In-Home: Audio users
Door loudspeakers, call buttons 10
Power supply, 12 line rectiers
Switching, control 13
Software, PC interface,
DoorCom 14
Bus indoor devices 15
Jung indoor stations 17
Accessories 18
6 Installation
General information 20
Bus call button module,
b 21us line rectier
Modular Jung indoor station 22
6.1 Installation audio
Siedle Vario 24
Siedle custom-t door loud-
speaker 26
Siedle Classic 28
Siedle Steel 30
Siedle Vario with Intercom
functions 32
Siedle Vario 2 door stations 34
Multiple line system 36
Call via display call module 38
DoorCom 40 Analog DCA650-…
6.2 Siedle Systemtechnik
installation
Jung audio indoor station 42
Siedle and Jung indoor stations
combined 44
7 Programming
Overview of functions 46
Remarks 50
7.1 Programming – manual
Activating the bus line rectier 51
Activating the bus door loud-
speaker 52
Activating the indoor devices 53
Activating Jung indoor devices 54
Door call to Siedle Basic 55
Door call to bus telephone 56
Door call to bus handsfree tele-
phone 57
Door call via the storey call
button 58
Parallel door call 59
Internal call 60
Dialling the door station 62
Call differentiation of
2 door stations 63
Additional contact on the
BSM650-64
Button of a bus telephone on
the BSM650-… 65
Call button of a door station on
the BSE650- 66
Button of a bus telephone on
the BSE650- 67
Bus secondary signal unit
BNS750-… 68
Call via DRM 612 69 -…
Door call to Jung indoor station 70
Parallel door call to Jung indoor
station 71
Internal call between Jung
indoor stations 72
7.2 Programming – Plug+Play
Basics 74
Example o 76f a 4-family home
Procedure – Example 77
7.3 Programming – with PC
BPS650-… and PRI602-…USB 78
3
Conguration “Single line“
The In-Home bus: The Audio system
comprises a bus installation with
a two-core line permitting the
connection of up to 31users, e.g.
bus telephones, handsfree bus
telephones, door stations or devices
for switching and control functions.
Technically speaking, one device can
occupy more than one user.
The line has its own bus line rectier
for central functions such as speech,
door release or light switching.
The two cores assume the dual
functions of power supply and also
transmission of audio, switching
and control signals. Junction points
and branches are admissible at any
optional position in the line. In order
to connect more than 31users, sev-
eral Siedle In-Home: Audio lines can
be interconnected.
Conguration “Multiple line“
In-Home: Audio “Single line“ is
restricted to 31users; In order to
connect more than 31users, up to
15lines can be coupled together.
Each line requires its own bus
line rectier. Junction points and
branches are admissible at any
optional position in the line.
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualied
electrician. Failure to observe this
regulation could result in the risk of
serious damage to health or fatal
injury due to electric shocks.
• When working at the device,
observe the remarks relating to
mains cut-off.
Observe the DIN EN60065
standard! When establishing the
electronic connection, observe
the requirements of VDE0805 or
EN60950.
• The building installation must
include an all-pole mains switch
with a contact separation of at least
3mm.
Ensure maximum fusing of 16A
for the mains connection in the
building installation.
When planning large-scale
(complex) systems, the distributor
space required for the switch panel
mounting devices must be taken
into consideration in the distributor
planning process.
No external voltages >30VAC/DC
may be applied to bus users.
Devices with 230V connection
In accordance with DIN VDE0100
part410, section 411.1.3 attention
must be paid to ensuring a safe
separation between system lines
and the mains voltage; i.e. system
and mains cores must not be per-
mitted to touch! The system line
cable (extra-low safety voltage) must
be stripped back by the minimum
possible.
1 In-Home bus: Audio
System description
3 Safety remarks
Danger
“Siedle Systemtechnik“ and the
relevant logo are used to describe
devices, components or systems
which are not manufactured
and designed by Siedle but are
tted with Siedle technology. The
Systemtechnik logo guarantees tech-
nical compatibility with the Siedle
system world. Products identied
with “Siedle Systemtechnik“ may
therefore be used without restric-
tions as components of a Siedle
communication system.
Jung indoor stations in switch
design
Within the framework of a cooper-
ation agreement with the company
Jung, Siedle equips Jung indoor sta-
tions with “Siedle Systemtechnik“.
Indoor stations from Jung which
bear the Systemtechnik logo on
their components, their packaging
or the product information, are fully
compatible with Siedle technology.
They are integrated in this manual as
Siedle system components.
2 Siedle Systemtechnik
Jung indoor stations

Especificaciones del producto

Marca: Jung
Categoría: No categorizado
Modelo: SIAILS6

¿Necesitas ayuda?

Si necesitas ayuda con Jung SIAILS6 haz una pregunta a continuación y otros usuarios te responderán




No categorizado Jung Manuales

No categorizado Manuales

Últimos No categorizado Manuales