Installation Manual 1
P/No.: 3828A21005E
LG BRANCH DISTRIBUTOR UNIT
INSTALLATION MANUAL
(PMBD3620/PMBD3630/PMBD3640/PMBD7230
PMBD5420L/PMBD5430L/PMBD5440L)
To prevent injury to the user or other people and property damage, the following instructions
must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness
is classified by the following indications.
Meanings of symbols used in this manual are as shown below.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
Be sure not to do.
Be sure to follow the instruction.
Be sure to establish an earth connection.
Safety Precautions
WARNING
For electrical work, contact the
dealer, seller, a qualified
electrician, or an Authorized
Service Center.
Do not disassemble or repair the
product. There is risk of fire or
electric shock.
Be cautious when unpacking and
installing the product.
Sharp edges could cause injury. Be
especially careful of the case edges
and the fins on the condenser and
evaporator.
Install the panel and the cover of
control box securely.
There is risk of fire or electric shock.
ENGLISH ITALIANO FRANÇAISESPAÑOL DEUTSCH
2Branch Distributor
Safety Precautions
Do not place anything on the
power cable.
• There is risk of fire or electric shock.
Take care to ensure that power
cable could not be pulled out or
damaged during operation.
There is risk of fire or electric shock.
Do not place a heater or other
appliances near the power cable.
There is risk of fire and electric
shock.
Always ground the product.
There is risk of fire or electric shock
Do not install, remove, or re-install
the unit by yourself (customer).
There is risk of fire, electric shock,
explosion, or injury.
Do not allow water to run into
electric parts.
It may cause there is risk of fire,
failure of the product, or electric
shock.
For installation, always contact the
dealer or an Authorized Service
Center.
There is risk of fire, electric shock,
explosion, or injury
Do not modify or extend the power
cable.
There is risk of fire or electric shock.
Do not install the product on a
defective installation stand.
It may cause injury, accident, or
damage to the product.
CAUTION
Parts
1. INSTALLATION MANUAL
2. HANGER METAL
3. SCREWS
4. SOCKET
5. INSULATION PE
1 pc
(Nut: ø15.88, Socket: ø12.7)
(PMBD7230 ONLY)
4 pcs
12 pcs
1 pc
2 pcs
Items to be prepared in the field
• Connecting wires
(H05VV, 4 wires, 0.75mm, or 1.2mm)
• Installation parts
(Hanging bolts: 4 x M10 or M8, Nuts: 12, flat
washers:8)
Screws for wall-mounting : 6 x M5
Insulation
Brass cap
Aluminum tape
If strange sound, or smell or smoke comes from
product.
• Turn the breaker off or disconnect the power supply
cable. There is risk of electric shock or fire
Do not let the air conditioner run for a long time when
the humidity is very high and a door or a window is
left open.
Moisture may condense and wet or damage furniture.
Keep level even when installing the
product.
To avoid vibration or water leakage.
Always check for gas (refrigerant)
leakage after installation or repair
of product.
Low refrigerant levels may cause
failure of product.
Do not step on or put anyting on
the product. (outdoor units)
• There is risk of personal injury and
failure of product.
90˚
Safety Precautions
Installation Manual 3
ENGLISH

Especificaciones del producto

Marca: LG
Categoría: aire acondicionado
Modelo: PMBD3640
Color del producto: Zwart
Peso.: 407 g
Ancho: 77.1 mm
Profundidad: 115.5 mm
Altura: 26 mm
Material de la carcasa: Metaal
Código de seguridad internacional (IP): IP30
Indicadores LED: Fault, LAN, Link, Power, Status, WAN
Tipo de embalaje: Doos
Colocación: Muur
Herramientas de montaje: Ja
Banda de frecuencia: 2.412 - 5.700 GHz
Guía de inicio rápido: Ja
Número de puertos Ethernet LAN (RJ-45): 2
Consumo de energía (máx.): 11.7 W
Certificación: EMC, EMI, EMS
A PESAR DE: Ja
Conexión para adaptador de red: Ja
Sensibilidad del receptor: Typ. -90 @ 6 Mbps\nTyp. -88 @ 9 Mbps\nTyp. -87 @ 12 Mbps\nTyp. -85 @ 18 Mbps\nTyp. -81 @ 24 Mbps\nTyp. -78 @ 36 Mbps\nTyp. -74 @ 48 Mbps\nTyp. -73 @ 54 Mbps
LAN Ethernet, velocidades de transferencia de datos: 10, 100 Mbit/s
Tecnología de cableado: 10/100/1000Base-T(X)
Estándar de red: IEEE 802.11a, IEEE 802.11b, IEEE 802.11g, IEEE 802.11n
Algoritmos de seguridad compatibles: AES, HTTPS, SSH, SSL/TLS, WPA-TKIP
tipo de antena: Extern
Cantidad de antenas: 2
Nivel de ganancia de antena (máx.): 2 dBi
RS-232: Ja
Temperatura de almacenamiento: -40 - 85 °C
Humedad de almacenamiento: 5 - 95 procent
Botón de reinicio: Ja
Filtrado de direcciones MAC: Ja
filtro de dirección IP: Ja
Servidor DHCP: Ja
tipo MIMO: Multi User MIMO
Conexión de antena: RP-SMA
Velocidad máxima de transferencia de datos: 300 Mbit/s
2,4GHz: Ja
5GHz: Ja
Canal de Banda ancha: 20 MHz
VLAN=soporte: Ja
cliente DHCP: Ja
Alimentación a través de Ethernet (PoE): Nee
Funciones de antena: Afneembare antenne
Número de conectores: 2
Velocidad máxima de transferencia de datos (2,4 GHz): 54 Mbit/s
Velocidad máxima de transferencia de datos (5 GHz): - Mbit/s
Número de canales: 13 kanalen
Protocolos de gestión: DHCP Server/Client, HTTP, IPv4, LLDP, SMTP, SNMPv1/v2c/v3, Syslog, TCP/IP, Telnet, UDP, Proxy ARP, VLAN, Wireless Search Utility, MXview, MXview Wireless, MXconfig
transmitir potencia: 23 dBmW
voltaje-de-entrada-de-CA: 9 - 30 V
Temperatura de funcionamiento (TT): 0 - 60 °C
Humedad relativa de funcionamiento (VV): 5 - 95 procent
Número-de-productos-incluidos: 1 stuk(s)
registro-del-sistema: Ja
Tipo de dirección de antena: Omni-directioneel
Método de espectro ensanchado: DSSS, OFDM
Servicio de usuario de autenticación remota telefónica (RADIUS): Ja
6GHz: Nee

¿Necesitas ayuda?

Si necesitas ayuda con LG PMBD3640 haz una pregunta a continuación y otros usuarios te responderán




aire acondicionado LG Manuales

aire acondicionado Manuales

Últimos aire acondicionado Manuales