COMMERCIAL PROTECTOR SYSTEM®
INSTALLATION INSTRUCTIONS
To reduce the risk of SERIOUS INJURY or DEATH:
This device is for use ONLY on LiftMaster® Commercial Door
Operators.
For INDOOR USE ONLY.
Disconnect power BEFORE installing the Commercial Protector
System®.
READ AND FOLLOW ALL INSTRUCTIONS.
Facing the door from inside the garage (installation procedures are the same for all door types).
Left Side of Garage Right Side of Garage
Photoelectric Sensor
Photoelectric Sensor
Invisible Light Beam
Protection Area
THE COMMERCIAL PROTECTOR SYSTEM®
IMPORTANT INFORMATION ABOUT THE PHOTOELECTRIC SENSORS
Be sure power to the operator is disconnected.
When properly connected and aligned, the photoelectric sensors will detect an obstruction in the path of its invisible light beam. If an
obstruction breaks the light beam while the door is closing, the door will stop and typically reverse to the full open position.
The photoelectric sensors must be installed inside the garage so that the sending and receiving sensors face each other across the door,
no more than 6" (15 cm) above the fl oor. Either can be installed on the left or right of the door as long as the sun never shines directly
into the receiving eye lens. This product is not suitable for outdoor use.
The brackets must be securely fastened to a solid surface such as the wall framing. If installing in masonry construction, add a piece of
wood at each location to avoid drilling extra holes in masonry if repositioning is necessary.
The invisible light beam path must be unobstructed. No part of the garage door (or door tracks, springs, hinges, rollers or other
hardware) may interrupt the beam while the door is closing. If it does, use a piece of wood to build out each sensor mounting location to
the minimum depth required for light beam clearance.
APPLICATION
The Commercial Protector System® (CPS) is suitable for LiftMaster
Commercial Door Operators with a Normally Open (N.O.) sensing
edge input.
The CPS is for use with ancillary entrapment protection devices
only, and not used for primary monitored entrapment protection
devices.
CARTON INVENTORY
PART # DESCRIPTION QTY
CPS-U Photoelectric Sensors with Mounting Hardware 1
41K4629 Commercial Protector Interface 1
WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov
2
INSTALLATION
ASSEMBLE AND MOUNT THE BRACKETS
The following instructions show recommended assembly of the
bracket(s) and “C” wrap based on the wall installation of the
photoelectric sensors on each side of the door or on the door
tracks themselves. There are also alternate mounting methods
which may fi t your installation requirements better.
Make sure the wraps and brackets are aligned so the
photoelectric sensors will face each other across the door.
1 Fasten the “C” wraps to the mounting brackets having square
holes, using hardware shown.
WALL INSTALLATION
2 Connect each assembly to a slotted bracket, using the hardware
shown. Note alignment of brackets for left and right sides of
the door.
3 Finger tighten the lock nuts.
4 Use bracket mounting holes as a template to locate and drill
(2) 3/16" diameter pilot holes on both sides of the garage
door, 4-6 inches (10-15 cm) above the fl oor. Do not exceed
6 inches (15 cm).
5 Attach bracket assemblies with 1/4"x1-1/2" lag screws.
6 Adjust right and left side bracket assemblies to the same
distance out from mounting surface. Make sure all door
hardware obstructions are cleared. Tighten the nuts securely.
DOOR TRACK INSTALLATION
2 Discard slotted bracket. Drill 3/8" holes in each track and fasten
securely with hardware .
Mounting Bracket
with Square Holes “C” Wrap
#10-32x3/8"
Screws
#10-32
Lock Nuts
1/4"x1-1/2"
Lag Screws
1/4"-20x12" Carriage Bolts
(with square shoulders)
1/4"-20
Lock Nuts
Mounting Bracket
with Slot
Mounting Bracket with
Square Holes
“C” Wrap
ALTERNATE WALL INSTALLATION ALTERNATE FLOOR INSTALLATION
Mounting Bracket
with Slot
Mounting Bracket
with Square Holes
“C” Wrap
Photoelectric Sensor with Wire
Indicator Light
Floor
Photoelectric Sensor with Wire
Inside
Wall Indicator Light
Mounting Bracket with
Square Holes
Mounting Bracket
with Slot
“C” Wrap
Floor
Attach with Concrete
Anchors (Not Provided)
“C” Wrap
Mounting Bracket with
Square Holes
1/4" Lock Nuts
Door Track
Drill 3/8" Holes
1/4"-20x1/2"
Carriage Bolts
Inside
Wall
Inside
Wall
Inside
Wall
3
INSTALLATION
MOUNT AND WIRE THE PHOTOELECTRIC SENSORS
1 Center each photoelectric sensor in the bracket with the lenses
pointing toward each other across the door.
2 Attach the photoelectric sensors to the brackets with the
provided hardware. Finger tighten the receiving sensor wing
nut. Securely tighten the sending sensor wing nut.
3 Run the photoelectric sensor wires to the operator. Fasten the
photoelectric sensor wires appropriately.
4 Connect the photoelectric sensor wires to the operator (refer to
CPS Wiring Connections, page 5).
Sensor Wire
Indicator Light
“C” Wrap
Wing Nut
1/4"-20x1-1/2" Hex Bolt
Photoelectric
Sensor
Photoelectric Sensor
6" (15 cm) max. above fl oor
Photoelectric Sensor
6" (15 cm) max. above fl oor
Invisible Light Beam
Protection Area
Sensor Wires
Connect Sensor Wire to Operator
(refer to CPS Wire Connections, page 5)

Especificaciones del producto

Marca: Liftmaster
Categoría: No categorizado
Modelo: 41K4629
Color del producto: Zwart
Ancho: 140 mm
Profundidad: 150 mm
Altura: 86 mm
Interruptor encendido / apagado: Ja
Certificación: CB(62368+60950) / TUV / cTUVus / CE / FCC / BSMI / CCC / RCM / EAC / EAC RoHS / NOM
Destinado a: PC
Certificados de sostenibilidad: RoHS
Protección de voltaje de energía: Over current, Over power, Over voltage, Overheating, Short circuit, Under voltage
Certificación 80 PLUS: 80 PLUS Bronze
Tiempo medio entre fallos (MTBF): 100000 uur
Los activos totales: 550 W
Factor de potencia: 0.99
Tipo de enfriamiento: Actief
voltaje-de-entrada-de-CA: 100 - 240 V
Frecuencia-de-entrada-de-CA: 50 - 60 Hz
Diámetro del ventilador: 120 mm
Conector de alimentación de la placa base: 24-pin ATX
Factor de forma de fuente de alimentación (PSU): ATX
Tecnología de rodamientos: FDB
Número de conectores de alimentación SATA: 5
Tipo de cableado: Niet-modulair
Conectores de alimentación PCI Express (6+2 pines): 2
Conector de alimentación EPS (4+4 pines): Ja

¿Necesitas ayuda?

Si necesitas ayuda con Liftmaster 41K4629 haz una pregunta a continuación y otros usuarios te responderán




No categorizado Liftmaster Manuales

No categorizado Manuales

Últimos No categorizado Manuales