For Light Duty Commercial Use
Install On Sectional Doors With
Torsion Assemblies Only
NOT FOR RESIDENTIAL USE
Light-Duty Jackshaft Operator
for Sectional Doors
Model LJ8900W
LiftMaster
300 Windsor Drive
Oak Brook, IL 60523
Please read this manual and the enclosed safety materials carefully!
The door WILL NOT CLOSE unless the Protector System® and cable tension monitor
are connected and properly aligned.
Periodic checks of the operator are required to ensure safe operation.
The model number is located on the front cover of the operator.
DO NOT exceed 10 complete cycles of door operation per hour.
This product is to be installed and serviced by a trained door systems technician only.
This product may require adjustments to door springs and/or track configurations. This
product is not intended for use on low headroom tracks with outside pickup drum or
doors utilizing extension springs.
2 YEAR WARRANTY
After Installation, Please Leave with Customer
Register your door operator to receive updates and offers from LiftMaster
Take a photo of the
camera icon including
the points ( ).
Send it in by texting
the photo to 71403
(US) or visit
www.liftmaster.photo
(Global)
2
Introduction
When you see these Safety Symbols and Signal Words on the following pages, they
will alert you to the possibility of if you do not comply with the serious injury or death
warnings that accompany them. The hazard may come from something mechanical or
from electric shock. Read the warnings carefully.
When you see this Signal Word on the following pages, it will alert you to the possibility
of damage to your door and/or the door operator if you do not comply with the cautionary
statements that accompany it. Read them carefully.
Mechanical
Electrical
Safety Symbol and Signal Word Review
This door operator has been designed and tested to offer safe service provided it is installed, operated, maintained and tested in strict
accordance with the instructions and warnings contained in this manual.
Table of Contents
Introduction 2
Safety Symbol and Signal Word Review 2 ...
Planning 3 ....................................................
Preparing Your Door 4 .................................
Tools Needed 4 ............................................
Carton Inventory 5 .......................................
Hardware 5 ..................................................
Additional Items You May Need 5 ................
Assembly 6
Attach the Collar to the Door Operator 6 ......
Attach Mounting Bracket to
Door Operator 7 ...........................................
Installation 7
Position and Mount the Door Operator 8 .....
Attach the Emergency Release Rope
and Handle 9 ................................................
Install the Automatic Door
Lock (Not Provided) 9 ..................................
Attach the Cable Tension Monitor
(Required) 10 ...............................................
Install the Single Button
Control Station 11 ........................................
Install the Protector System 12 ....................
Install the Light Curtain (Not Provided) 15 ...
Connect Power 16 ........................................
Install the Battery
Backup (Not Provided) 18 ............................
Adjustments 19
Program the Travel 19 .................................
Automatic Force Setup............................19
Test the Safety Reversal System 20 .............
Test the Protector System 20 .......................
Test Cable Tension Monitor 21 ....................
Test Automatic door lock 21 ........................
To Open the Door Manually 21 ....................
Operation 22
Using Your Door Operator 23 ......................
Programming 24
Remote Control (Not Provided) 24 ...............
To Erase the Memory 24 ..............................
Maintenance 25
Care of Your Door Operator 25 ....................
Troubleshooting 26
Diagnostic Chart 26 .....................................
Additional Troubleshooting 27 .....................
Repair Parts 29
Installation Parts 29 .....................................
Door Operator Parts 29 ................................
Accessories 30
Contact Information 30
WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause
cancer or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
3
Planning
Survey your area to see if any of the conditions below apply to your installation.
Depending on your requirements, additional materials may be required.
THIS DOOR OPERATOR IS COMPATIBLE WITH:
Doors that use a torsion bar and springs. The torsion bar must be 1" (2.5 cm)
diameter. NOT compatible with reverse wound drums.
4-6" (10-15 cm) drums, not to be used on tapered drums over 6" (15 cm).
High lift (up to 54" (137.2 cm) high) and standard lift sectional doors up to 14 ft.
(4.3 m) high.
Doors up to 18 ft. (5.5 m) wide.
Doors up to 180 sq. ft. (16.7 sq. m).
Review or inspect proposed installation area. The door operator can be installed on the left
or right side of door. Select the side that meets the requirements listed below.
a. Must have minimum of 2.5" (6.4 cm)
between the wall and the center of the
torsion bar.
b. Must have minimum of 3" (7.6 cm)
between the ceiling and the center of
torsion bar.
c. Must have minimum of 8.5" (21.6cm)
between the side wall (or obstruction)
and the end of torsion bar.
d. The torsion bar must extend at least
1.5" (3.81 cm) past the bearing.
This may vary depending on your
installation requirements.
e. An electric outlet is required within
6ft. (1.83 m) of the installation area.
If outlet does not exist, contact a
qualified electrician.
f. Depending upon building
construction, extension brackets or
wood blocks may be needed to install
safety reversing sensors and cable
tension monitor.
g. Alternate floor mounting of the
safety reversing sensors will require
hardware (not provided).
h. Check the seal on the bottom of the
door. Any gap between the floor and
the bottom of the door must not
exceed 1/4 inch (6 mm). Otherwise,
the safety reversal system may not
work properly.
Introduction
NOTE: Inspect the torsion bar while the
door is raised and lowered. It is important
that there is no noticeable movement up
and down or left and right. If the movement
is not corrected, the life of the door
operator will be greatly reduced.
a
b
h
c
d
e
f
g
Torsion
bar
2.5"
(6.4 cm)
3"
(7.6 cm)
Wall or
obstruction
Torsion bar
8.5"
(21.6cm)
Safety
reversing
sensor
myQ LED
Remote Light
(Not provided)
Automatic
door lock
(Not
provided)
Door spring

Especificaciones del producto

Marca: Liftmaster
Categoría: No categorizado
Modelo: LJ8900W
Tipo de operación: Lever, Rotary
Color del producto: Black, Stainless steel
Peso.: 2560 g
Indicador de nivel de agua: Ja
Amable: Niet-geïsoleerd
Función mantener caliente: Ja
Material de la carcasa: Roestvrijstaal
Activos: 1500 W
Interruptor encendido / apagado: Ja
Luz indicadora: Ja
Temperatura-ajustable: Ja
Uso recomendado: Warme dranken
Protección contra sobrecalentamiento: Ja
Contenido: 16 l
Manejas): Ja
Número de jeringas: 1
Portátil: Ja
voltaje-de-entrada-de-CA: 230 V
Frecuencia-de-entrada-de-CA: 50 Hz

¿Necesitas ayuda?

Si necesitas ayuda con Liftmaster LJ8900W haz una pregunta a continuación y otros usuarios te responderán




No categorizado Liftmaster Manuales

No categorizado Manuales

Últimos No categorizado Manuales