Lincoln Electric Cool Arc 50 Manual de Usario

Lee a continuación 📖 el manual en español para Lincoln Electric Cool Arc 50 (13 páginas) en la categoría No categorizado. Esta guía fue útil para 4 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/13
IM3017
04/2021
REV05
COOL ARC® 50
OPERATOR’S MANUAL
ENGLISH
Lincoln Electric Bester Sp. z o.o.
ul. Jana III Sobieskiego 19A, 58-260 Bielawa, Poland
www.lincolnelectric.eu
English English
I
12/05
THANKS! For having chosen the QUALITY of the Lincoln Electric products.
Please Examine Package and Equipment for Damage. Claims for material damaged in shipment must be notified
immediately to the dealer.
For future reference record in the table below your equipment identification information. Model Name, Code & Serial
Number can be found on the machine rating plate.
Model Name:
……………………………………………………………………………………………………………………………………….
Code & Serial Number:
……………………………………………………………….. …………………………………………………………………..
Date & Where Purchased
………………………………………………………………. …………………………………………………………………..
ENGLISH INDEX
Technical Specifications ............................................................................................................................................................... 1
Electromagnetic Compatibility (EMC) .......................................................................................................................................... 2
Safety............................................................................................................................................................................................ 3
Introduction ................................................................................................................................................................................... 5
Installation and Operator Instructions .......................................................................................................................................... 5
WEEE ......................................................................................................................................................................................... 10
Spare Parts ................................................................................................................................................................................. 10
REACh ........................................................................................................................................................................................ 10
Authorized Service Shops Location ........................................................................................................................................... 10
Electrical Schematic ................................................................................................................................................................... 10
Accessories ................................................................................................................................................................................ 11
English English
1
Technical Specifications
NAME INDEX
COOL ARC® 50 K14050-1
INPUT
Input Voltage Input Amperes I
1max Frequency EMC Class
400/230 V ± 10%
single phase 1,2A 50/60Hz A
RATED OUTPUT AT 40°C
Flow range
MIG
TIG
Open flow
0,5 to 3,3 l/min
with torch 4,5m: 1,7 1,8 l/min
with torch 3,8m: 1,3 1,4 l/min
3,3 l/min
PARAMETERS RATING
The cooling power of flow 1liter per minute at temperature of
25°C Maximum pressure rate
1,15 kW 0,4 MPa
PARAMETERS O FTHE COOLER’S RESERVOIR
Maximum reservoir capacity Minimum required reservoir capacity
9,2 l 6 l
COOLANT
Recommended coolant FREEZCOOL - W000010167
Do not use!!
Pre-packaged welding industry coolants. These coolants may contain oil-based
substances, which attack the plastic components of the cooler. Once added to the cooler,
these substances are impossible to purge from the water lines and heat exchanger.
Automotive anti-freeze. These coolants will damage the pump and block of the heat
exchanger, affecting cooling performance.
PHYSICAL DIMENSIONS
Height Width Length Weight
265 mm 355 mm 680 mm 21 kg
Protection Rating Operating Temperature Storage Temperature
IP23 -10°C (14°F) to +40°C (104°F) -25°C (-13°F) to +55°C (131°F)