Installaon Manual
Type
LED Power Supply
Families
AP, CEN, CLG, ELG, ELN, GSC, HBG, HLG, HLN, HLP, HSG, HVG, LCM, LP, LPF, PLC, NPF, OWA, PCD,
PLC, PLD, PLM, PLN, PLP, PWM, ULP
Introducon
The LED power supply is a dedicated LED driving device that delivers a constant current/voltage or generates an
adjustable current controlled by an external dimmer to LEDs. Depending on its types or design concept, some of
them not only have PFC capability but also can be located in a harsh environment such as dusty, humid places.
Mean Well’s LED power supplies include metal case, plasc case, and PCB types.
Installaon
( )1 Before commencing any installaon or maintenance work, please disconnect the power supply from the ulity.
Ensure that it cannot be re-connected inadvertently!
( )2 Keep proper venlaon around the unit and do not stack any object on it. Also a 10-15 cm clearance must be
kept when the adjacent device is a heat source.
( )3 Mounng orientaons other than standard orientaon or operate under high ambient temperature may
increase the internal component temperature and will require a de-rang in output current. Please refer to
the specicaon sheet to receive the opmum mounng posion and informaon about the -rang curve. de
( )4 Current rang of an approved primary /secondary cable should be greater than or equal to that of the unit.
Please refer to its specicaon.
( )5 For LED power supplies with waterproof connectors, verify that the linkage between the unit and the lighng
xture is ght so that water cannot intrude into the system.
( )6 For dimmable LED power supplies, make sure that your dimming controller is capable of driving
these units. For ELN series, either “D” or “Ptype, require 40mA each unit; for those with “3 in 1” dimming
funcon, e.g. HLG and LPF series, require 0.15mA each unit.
( )7 Wiring: The wire color will vary by country, please refer to the table below.
North America
European Harmonized
Live and ACL
Black
Brown
Neutral and ACN
white
Blue
PE and FG (Class I only)
Green
Green/yellow
( )a Connect the FG wire (green or green/yellow) of the LED power supply to (green or green/yellow), this PE
step can be skipped when the unit is marked class II, ungrounded.
( )b Connect the ACL wire (black or brown) of the LED power supply to Live (black or brown).
( )c Connect the ACN wire (white or blue) of the LED power supply to Neutral (white or blue).
Installaon Manual
( )8 The maximum number of the LED PSUs that can be connected to a circuit breaker at 230V is shown as below.
Model
B10
B16
C10
C16
D10
D16
APC-8
17
18
29
37
59
APC- 12
17
18
29
37
59
APC- 16
13
14
23
28
46
APC- 25
9
9
15
18
30
APC- 35
5
6
9
12
19
APC- 8E
17
18
29
37
59
APC- 12E
17
18
29
37
59
APC- 16E
13
14
23
26
42
APV-8
17
18
29
37
59
APV- 12
17
18
29
37
59
APV- 16
13
14
22
28
44
APV- 25
9
9
15
18
30
APV- 35
6
6
10
13
21
APV- 8E
17
18
29
37
59
A -12E PV
17
18
29
37
59
APV-16E
13
14
22
28
44
CEN- 60
32
20
32
20
32
CEN- 75
25
16
25
16
25
CEN-100
19
11
19
11
19
CLG- 60
32
20
32
20
32
CLG- 100
3
3
5
6
10
CLG- 150
3
3
5
6
10
ELG- 75
7
7
11
14
23
ELG- 100
3
4
6
8
12
ELG- 150
3
3
5
6
11
ELG- -C 75
7
7
11
14
23
ELG- -C 100
3
4
6
8
12
ELG- -C 150
3
4
6
8
13
ELN- 30
4
5
8
10
16
ELN- 60
3
3
5
7
11
GSC18
42
26
42
26
42
GSC25
42
26
42
26
42
GSC40
36
22
36
22
36
HBG- 100
4
5
8
10
16
HBG- 160
4
4
7
8
12
HBG- 240
2
2
3
4
7
HBG- 60
28
20
32
20
32
Installaon Manual
Model
B10
B16
C10
C16
D10
D16
HLG- 40H
7
12
13
20
26
41
HLG- 60H
6
9
10
16
20
32
HLG- 80H
2
3
3
6
7
12
HLG- 100H
3
4
5
8
10
16
HLG- 120H
3
5
5
9
10
17
HLG- 150H
2
4
4
7
8
13
HLG- 185H
2
4
4
7
6
11
HLG- 240H
1
2
3
4
5
8
HLG- 320H
1
1
1
2
3
5
HLG- 600H
1
1
1
2
2
3
HLG- -C 60H
5
8
8
13
16
26
HLG- -C 80H
3
4
5
8
10
16
HLG- -C 120H
2
4
4
6
8
13
HLG- -C 185H
1
2
2
3
4
7
HLG- -C 240H
1
2
2
3
4
7
HLG- -C 320H
0
1
1
2
3
5
HLN- 40H
7
12
13
20
26
41
HLN- 60H
6
9
10
16
20
32
HLN- 80H
2
3
3
6
7
12
HLP- 40H
7
12
13
20
26
41
HLP- 60H
6
9
10
16
20
32
HLP- 80H
2
3
3
5
6
10
HSG- 70
4
6
7
11
14
22
HVG-65 (480V)
7
12
12
20
25
40
HVG-100 (480V)
3
5
5
8
10
17
HVG-150 (480V)
2
4
4
6
8
13
HVG-240 (480V)
2
4
4
7
9
15
HVG-320 (480V)
1
2
2
4
5
8
HVGC-65 (480V)
7
12
12
20
25
40
HVGC-100 (480V)
3
5
5
8
10
17
HVGC-150 (480V)
2
4
4
6
8
13
HVGC-240 (480V)
2
4
4
7
9
15
HVGC-320 (480V)
1
2
2
4
5
8
LCM- 25
16
26
27
44
50
80
LCM- 40
16
26
27
44
29
47
LCM- 60
15
25
20
32
20
32
LCM-25DA
16
26
27
44
50
80
LCM-40DA
16
26
27
44
29
47
LCM-60DA
15
25
20
32
20
32
LPC- 20
5
8
9
14
18
29
LPC- 35
2
4
4
7
9
15

Especificaciones del producto

Marca: Mean Well