Installation Manual
Type
Medical Switching Power Supply
(1) Enclosed (Families: MSP)
(2) Modular (Families: MP, NMP)
(3) PCB (Families: MPS, MPD, MPT, MQ, RPS, RPD, RPT, RPTG, NEM, PM)
(4) Adaptor (Families: GSM, MES)
Installation
(1) Enclosed Type
(a) Before any installation or maintenance work, please disconnect your system from the utility.
Ensure that it cannot be re-connected inadvertently!
(b) Mounting orientations other than standard orientation or operate under high ambient
temperature may increase the internal component temperature and will require a de-rating in
output current. Please refer to the specification sheets to receive the optimum mounting
position and information about the de-rating curve.
(c) Fans or ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance
must be kept when the adjacent device is a heat source.
(d) Keep enough insulation distance between mounting screws and internal components of
Enclosed units. Please refer to case drawing on specifications to receive the maximum length of
mounting screw.
(e) Recommended wires of Enclosed units are shown as below.
AWG 18 16 14 12 10 8
Rated Current of
Equipment (Amp) 6A 6-10A 10-16A 16-25A 25-32A 32-40A
Cross-section of
Lead(mm2 ) 0.75 1.00 1.5 2.5 4 6
Note: The suggested maximum current above only suit for 1-4 strips, 5 or more
strips should not exceed 80% of current rating.
Make sure that all strands of each stranded wire enter the terminal connection and the screw
terminals are securely fixed to prevent poor contact.
(f) For other information about the products, please refer to www.meanwell.com for details.
(2) Modular Type
(a) Before any installation or maintenance work, please disconnect your system from the utility.
Ensure that it cannot be re-connected inadvertently!
(b) Mounting orientations other than standard orientation or operate under high ambient
temperature may increase the internal component temperature and will require a de-rating in
output current. Please refer to the specification sheets to receive the optimum mounting
position and information about the de-rating curve.
(c) Fans or ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance
must be kept when the adjacent device is a heat source.
(d) Keep enough insulation distance between mounting screws and internal components of
Modular units. Please refer to case drawing on specifications to receive the maximum length of
mounting screw.
(e) Recommended wires of Modular units are shown as below.
AWG 18 16 14 12 10 8
Rated Current of
Equipment (Amp) 6A 6-10A 10-16A 16-25A 25-32A 32-40A
Cross-section of
Lead(mm2 ) 0.75 1.00 1.5 2.5 4 6
Note: The suggested maximum current above only suit for 1-4 strips, 5 or more
strips should not exceed 80% of current rating.
Make sure that all strands of each stranded wire enter the terminal connection and the screw
terminals are securely fixed to prevent poor contact.
(f) For other information about the products, please refer to www.meanwell.com for details.
Installation Manual
(3) PCB Type
(a) Before any installation or maintenance work, please disconnect your system from the utility.
Ensure that it cannot be re-connected inadvertently!
(b) Mounting orientations other than standard orientation or operate under high ambient
temperature may increase the internal component temperature and will require a de-rating in
output current. Please refer to the specification sheets to receive the optimum mounting
position and information about the de-rating curve.
(c) Fans or ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance
must be kept when the adjacent device is a heat source.
(d) Recommended wires of PCB units are shown as below.
AWG 18 16 14 12 10 8
Rated Current of
Equipment (Amp) 6A 6-10A 10-16A 16-25A 25-32A 32-40A
Cross-section of
Lead(mm2 ) 0.75 1.00 1.5 2.5 4 6
Note: The suggested maximum current above only suit for 1-4 strips, 5 or more
strips should not exceed 80% of current rating.
Make sure that all strands of each stranded wire enter the terminal connection and the screw
terminals are securely fixed to prevent poor contact.
(e) At least 5mm insulation distance on the bottom of PCB units should be kept and a Mylar film
should be added between the units and the system. In addition, keep enough insulation
distance of 15mm around the PCB units.
(f) PCB units greater than 120W may require a forced air/fan for cooling. Please refer to
specifications to receive a minimum air intensity and air-flow direction.
(g) For other information about the products, please refer to www.meanwell.com for details.
(4) Adapter Type
(a) Before any installation or maintenance work, please disconnect your system from the utility.
Ensure that it cannot be re-connected inadvertently!
(b) Mounting orientations other than standard orientation or operate under high ambient
temperature may increase the internal component temperature and will require a de-rating in
output current. Please refer to the specification sheets to receive the optimum mounting
position and information about the de-rating curve.
(c) Fans or ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance
must be kept when the adjacent device is a heat source.
(d) Before attaching the DC plug of an adaptor to equipment, please unplug the adaptor from the
AC power and verify the unit is within the voltage and current rating on the equipment.
(e) Keep the linkage between the adaptor and its power cord tightly as well as connecting the DC
plug to equipment properly.
(f) Protect the power cord of adaptors from being trodden on or being squashed.
(g) An approved power cord of an adaptor should greater or equal to SVT, 3G×18AWG or H03VV-F,
3G×0.75mm2.
(h) If the final equipment is not used for long period of time, disconnect the equipment from
adaptors to avoid being damaged by voltage peaks or lightning strike.
(i) For other information about the products, please refer to www.meanwell.com for details.
User Manual
NMP series:
http://www.meanwell.com/webapp/product/search.aspx?prod=NMP1K2&pdf=Tk1QLUUucGRm&a=4
Installation Manual
Warning / Caution !!
(1) Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician.
Please do not remove the case of the power supply by yourself! Please do not install the units in
places with high moisture or near the water.
(2) Please do not install the units in places with high ambient temperature or near fire source. The
maximum ambient temperature, please refer to their specifications.
(3) Output current and output wattage must not exceed the rated values on specifications.
(4) To avoid risk of electric shock, for class I products, the ground (FG) must be connected to protective
earth.
(5) The Enclosed, Modular and PCB units are designed in accordance with EMC regulations and the
related test reports are available by request. Since they are belong to component power supplies
and will be installed inside system enclosure, when they are integrated into a system, the EMC
characteristics of the end system must be re-verified again.
Manufacturer
MEAN WELL ENTERPRISES Co., LTD.
No.28, Wuquan 3rd Rd., Wugu Dist.,
New Taipei City 24891, Taiwan
Tel: +886-2-2299-6100
Web: www.meanwell.com
Branch Office
China
MEAN WELL (GUANGZHOU)
ENTERPRISES Co., LTD.
2F, A Building, Yuean lndustry Park,
Huangcun,Dongpu Yown, Tianhe
District, Gungzhou, China
Post Code:510660
Tel: +86-20-2887-1200
Web: www.meanwell.com.cn
U.S.A.
MEAN WELL USA, INC.
44030 Fremont Blvd., Fremont,
CA 94538, U.S.A.
Tel: +1-510-683-8886
Web: www.meanwellusa.com
Europe
MEAN WELL EUROPE B.V.
Langs de Werf 8, 1185XT
Amstelveen, The Netherlands
Tel: +31-20-758-6000
Web: www.meanwell.eu

Especificaciones del producto

Marca: Mean Well
Categoría: No categorizado
Modelo: RPS-65-12
Color del producto: Black, White
Peso.: 510 g
Ancho: 120 mm
Profundidad: 120 mm
Altura: 91.7 mm
Amable: IP-beveiligingscamera
Material de la carcasa: Aluminium
Código de seguridad internacional (IP): IP66
Capacidad máxima de la tarjeta de memoria: 128 GB
Formato de audio soportado: ADPCM, G.711, G.726
factor vorm: Dome
Tecnología de conectividad: Bedraad
red LAN: Ja
Método de montaje: Plafond/muur
Resolución Máxima: 1920 x 1080 Pixels
Número total de megapíxeles: 2 MP
Formatos de compresión de vídeo: H.264, H.265, M-JPEG
Tipo de fuente de energía: DC, PoE
Número de cámaras: 1
Lector de tarjetas de memoria integrado: Ja
Tarjetas de memoria compatibles: MicroSD (TransFlash), MicroSDHC, MicroSDXC
Vision nocturna: Ja
tipo LED: IR
Distancia focal fija: 4 mm
Detección de movimiento por vídeo: Ja
Micrófono, entrada de línea: Ja
Número de puertos Ethernet LAN (RJ-45): 1
Consumo de energía (máx.): 6.4 W
Tamaño del sensor óptico: 1/2.8 "
Tipo de sensor de imagen: CMOS
Velocidad de obturación de la cámara: 1/5 - 1/12000 s
Memoria interna: 512 MB
balance de blancos: ATW, AWC, Indoor, Manual, Outdoor
Tipo cámarasluiter: Elektronisch
Resoluciones de gráficos compatibles: 640 x 360,640 x 480 (VGA),720 x 480,720 x 576,800 x 448,800 x 600 (SVGA),1280 x 720 (HD 720),1280 x 960,1920 x 1080 (HD 1080)
Reducción de ruido: Ja
Estándar de red: IEEE 802.3af
Algoritmos de seguridad compatibles: EAP-LEAP, EAP-TLS
Soporta Windows: Windows 10, Windows 8.1
Número de usuarios: 6 gebruiker(s)
Temperatura de almacenamiento: -30 - 60 °C
Máximo 30 cuadros por segundo: 30 fps
Protocolos de red compatibles: IPv4, IPv6, TCP/IP, UDP/IP, RTP(UDP), RTP(TCP), RTCP, RTSP, NTP, HTTP, HTTPS, SSL/TLS, DHCP, FTP, SMTP, ICMP, IGMP, SNMPv1/v2c/v3(MIB-2), ARP, DNS, DDNS, QoS, UPnP, Bonjour, LLDP
Soporta el sistema operativo Mac: Mac OS X 10.12 Sierra, Mac OS X 10.13 High Sierra, Mac OS X 10.14 Mojave
Humedad de almacenamiento: 0 - 90 procent
filtro de dirección IP: Ja
Salida de vídeo compuesto: 1
Memoria flash: 256 MB
Tipo de interfaz Ethernet: Fast Ethernet
Calidad de servicio (QoS): Ja
yo codifico: IK10
Frecuencia de muestreo: 8 kHz
Control PTZ: Ja
Ángulo de rotación: 355 °
rango de panorámica: 0 - 350 °
Número de lentes: 1
Número de apertura máxima: 1.6
Control de cámara panorámica: Ja
Función de inclinación de la cámara: Ja
Método de transmisión: Multicast, Unicast
Número de sensores: 1
Vídeo transmitido en vivo: Ja
Alcance de visión nocturna: 25 m
Filtro de terminación de infrarrojos (IR): Ja
Compensación de retroiluminación: Ja
Número de píxeles efectivos (H x V): 1920 x 1080 Pixels
Entrada/salida de alarma: Ja
control de velocidad de bits: Constant Bit Rate (CBR), Variable Bit Rate (VBR)
Consumo de energía (alimentación a través de Ethernet (PoE)): 7.4 W
Amplio rango dinámico (WDR): Ja
Consumo de energía (típico): 5.1 W
Temperatura de funcionamiento (TT): -30 - 55 °C
Humedad relativa de funcionamiento (VV): 0 - 90 procent
Rango de ángulo de inclinación: 0 - 67 °
Máscara zona privada: Ja
Análisis de comportamiento: Detectie van lijnoverschrijding
Funciones del sistema de videovigilancia inteligente (IVS): Defocus
Ángulo de visión de la lente, horizontal: 87.6 °
Girar y reflejar: Ja
Tipo de notificación de alerta: E-mail
Lente de ángulo de visión, diagonal: 104.5 °
Ángulo de visión de la lente, vertical: 46.4 °
Alarma activa de desmontaje no autorizado: Ja
Vasto foco: Ja

¿Necesitas ayuda?

Si necesitas ayuda con Mean Well RPS-65-12 haz una pregunta a continuación y otros usuarios te responderán




No categorizado Mean Well Manuales

No categorizado Manuales

Últimos No categorizado Manuales