Midea 2M-46K Manual de Usario
Lee a continuación 📖 el manual en español para Midea 2M-46K (39 páginas) en la categoría Airco. Esta guía fue útil para 7 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/39
Before using your air conditioner, please read
this manual carefully and keep it for future reference.
ROOM AIR CONDITIONER
Please read this installation manual completely
before installing the product.
If the power cord is damaged, replacement work
shall be performed by authorised personnel only.
Installation work must be performed in accordance
with the national wiring Standards by authorised
personnel only.
Contact an authorised service technician for
repair, maintenance or installation of this unit.
INVERTER ONE-TWO / ONE-THREE
/ONE- FOUR/ONE-FIVE SPLIT-TYPE
1
CONTENTS
SAFETY PRECAUTIONS
Warning ...........................................................................................................................................2
Caution ............................................................................................................................................2
INSTALLATION INSTRUCTIONS
Selecting installation place...............................................................................................................3
Wall-mounted type ...........................................................................................................................3
Accessories .........................................................................................................4
Four-way cassette type ................................................................................................................9
Duct & Ceiling type .......................................................................................................................15
Ceiling and Floor type ....................................................................................................................21
Floor and Standing type(Console)..................................................................................................24
Outdoor unit installation ................................................................................................................28
REFRIGERANT PIPE CONNECTION
Refrigerant pipe connection ..........................................................................................................29
Inside you will find many helpful hints on how to install and test the air conditioner properly.
All the illustrations and specifications in the manual are subject to change without prior notice for product
improvement. The actual shape should prevail.
Read This Manual
ELECTRICAL WORK
Electrical work .................. ...........................................................................................................30
TEST RUNNING
Test running ..................................................................................................................................37
AIR PURGING
Air purging with vacuum pump .....................................................................................................35
Safety and leakage check ............................................................................................................36
Contact an authorised service technician for repair or maintenance of this unit.
The appliance shall be installed in accordance with national wiring regulations.
This appliance is not intended for use by persons(including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Young children should be supervised to ensure that they do not play with the air conditioner.
Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
Installation work must be performed in accordance with the national wiring standards by
authorised personnel only.
CAUTION
2
SAFETY PRECAUTIONS
WARNING
Read the follow SAFETY PRECAUTIONS carefully before installation.
Electrical work must be installed by a licensed electrician. Be sure to use the correct rating
of the power plug and main circuit for the model to be installed.
Incorrect installation due to ignoring of the instruction will cause harm or damage.
The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
The items to be followed are classified by the symbols:
Symbol with background white denotes item that is PROHIBITED from doing.
CAUTION
This symbol indicates the possibility of injury or damage to property.
WARNING
1) Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water
leakage, electrical shock or fire.
2) Install according to this installation instructions strictly. If installation is defective, it will cause water
leakage, electrical shock or fire.
3) Use the attached accessories parts and specified parts for installation. otherwise, it will cause the set to fall,
water leakage, electrical shock or fire.
4) Install at a strong and firm location which is able to withstand the set s weight. If the strength is not enough
or installation is not properly done, the set will drop and cause injury.
,
5) For electrical work, follow the local national wiring standard, regulation and this installation instructions. An
independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found
in electrical work, it will cause electrical shock or fire.
6) Use the specified cable and connect tightly and clamp the cable so that no external force will be acted on
the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
7) Wiring routing must be properly arranged so that control board cover is fixed properly. If control board cover
is not fixed perfectly, it will cause heat-up at connection point of terminal, fire or electrical shock.
8) When carrying out piping connection, take care not to let air substances other than the specified
refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure
in the refrigeration cycle, explosion and injury.
9) Do not modify the length of the power supply cord or use of extension cord, and do not share the
single outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock.
CAUTION
1) This equipment must be earthed and installed with earth leakage current breaker. It may cause electrical
shock if grounding is not perfect.
2) Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and
accumulates at surrounding of the unit, it may cause fire.
3) Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water
may enter the room and damage the furniture.
5) Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
6) An all-pole disconnection device which has at least 3mm clearances in all poles , and have a
leakage current that may exceed 10mA, the residual current device (RCD) having a rated residual
operating current not exceeding 30mA, and disconnection must be incorporated in the fixed wiring
in accordance with the wiring rules.
4) The appliance shall be installed in accordance with national wiring regulations.
Especificaciones del producto
Marca: | Midea |
Categoría: | Airco |
Modelo: | 2M-46K |
¿Necesitas ayuda?
Si necesitas ayuda con Midea 2M-46K haz una pregunta a continuación y otros usuarios te responderán
Airco Midea Manuales
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
Airco Manuales
- Airco Zibro
- Airco Electrolux
- Airco Samsung
- Airco LG
- Airco AEG
- Airco Panasonic
- Airco BEKO
- Airco Delonghi
- Airco Daewoo
- Airco Grundig
- Airco Honeywell
- Airco Inventum
- Airco Siemens
- Airco Toshiba
- Airco Unold
- Airco Whirlpool
- Airco Vaillant
- Airco Adler
- Airco Amana
- Airco Argo
- Airco Arcelik
- Airco Bartscher
- Airco Tosot
- Airco Eurom
- Airco GE
- Airco Orbegozo
- Airco Sharp
- Airco Klarstein
- Airco Gorenje
- Airco Hitachi
- Airco Nedis
- Airco Thomson
- Airco Innoliving
- Airco Tristar
- Airco Domo
- Airco Trisa
- Airco Hotpoint-Ariston
- Airco Rowenta
- Airco Livoo
- Airco Manta
- Airco SereneLife
- Airco Hisense
- Airco Hyundai
- Airco Vox
- Airco Westinghouse
- Airco Emerio
- Airco RCA
- Airco Clatronic
- Airco Hotpoint
- Airco Sencor
- Airco Blaupunkt
- Airco Mabe
- Airco Frigidaire
- Airco Svan
- Airco Logik
- Airco Danby
- Airco Anslut
- Airco Daikin
- Airco Carson
- Airco Mesko
- Airco Profilo
- Airco Tripp Lite
- Airco Truma
- Airco Heinner
- Airco Sanyo
- Airco Jocca
- Airco Einhell
- Airco Kenmore
- Airco Philco
- Airco TCL
- Airco Guzzanti
- Airco Defy
- Airco Infiniton
- Airco Mitsubishi
- Airco Dometic
- Airco Aspes
- Airco Dimplex
- Airco DCG
- Airco Emerson
- Airco White Knight
- Airco Suntec
- Airco Orima
- Airco Haier
- Airco Gree
- Airco Evolar
- Airco Proline
- Airco Royal Sovereign
- Airco Corberó
- Airco Zelmer
- Airco Meaco
- Airco Fujitsu
- Airco Kelvinator
- Airco Element
- Airco Malmbergs
- Airco Everglades
- Airco Daitsu
- Airco Sanus
- Airco Wilfa
- Airco Carrier
- Airco Olimpia Splendid
- Airco Trotec
- Airco Saunier Duval
- Airco Camry
- Airco Qlima
- Airco Alpatec
- Airco Jocel
- Airco Comfee
- Airco Godrej
- Airco Sauber
- Airco Maiko
- Airco Tectro
- Airco Rotel
- Airco Becken
- Airco Bavaria
- Airco Equation
- Airco Edy
- Airco HTW
- Airco Maxicool
- Airco Dantherm
- Airco Thermex
- Airco Master
- Airco MundoClima
- Airco Argoclima
- Airco Baxi
- Airco Proklima
- Airco Sonnenkonig
- Airco Lavorwash
- Airco Climadiff
- Airco Fairland
- Airco Toyotomi
- Airco Just Fire
- Airco Furrion
- Airco Cecotec
- Airco Iceberg
- Airco Livington
- Airco Firstline
- Airco Holland Electro
- Airco Evapolar
- Airco EcoFlow
- Airco NewAir
- Airco Kogan
- Airco ActronAir
- Airco Klimaire
- Airco SEEGER
- Airco General Electric
- Airco Friedrich
- Airco Simplicity
- Airco Starlyf
- Airco Moa
- Airco Fuji Electric
- Airco Kibernetik
- Airco Prem-i-air
- Airco Céliera
- Airco Bodin
- Airco Brivis
- Airco MRCOOL
- Airco B-Air
- Airco Rinnai
- Airco GoldAir
- Airco Ravanson
- Airco Daizuki
- Airco Evapcool
- Airco Protector
- Airco Krone
- Airco ARCTIC WIND
- Airco Keystone
- Airco Cool-Space
- Airco VänEE
- Airco Perfect Aire
Últimos Airco Manuales
19 Septiembre 2024
19 Septiembre 2024
19 Septiembre 2024
19 Septiembre 2024
19 Septiembre 2024
19 Septiembre 2024
19 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024