Monogram ZV36RSFSS Manual de Usario
Lee a continuación 📖 el manual en español para Monogram ZV36RSFSS (16 páginas) en la categoría Afzuigkap. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/16
1
Monogram.
®
If you have questions, call 800-GE-CARES or visit our website at: www.monogram.com
Installation
Instructions
30", 36" and 48"
Professional
Restaurant Style
Vent Hoods
Models:
ZV48R
ZV36R
ZV30R
2
Installation Instructions
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRICAL
SHOCK OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
B. Before servicing or cleaning unit, switch power off at
the service panel and lock service panel to prevent
power from being switched on accidentally. If the
service panel cannot be locked, fasten a tag or
prominent warning label to the panel.
AVERTISSEMENT
POUR RÉDUIRE LE RISQUE D’INCENDIE, DE
CHOC ÉLECTRIQUE OU DE BLESSURES, IL FAUT
OBSERVER LES REGLES SUIVANTES:
A. Utiliser cet appareil uniquement de la maniére
prévue par le fabricant. En cas de question, consulter
le fabricant.
B. Avant toute intervention ou nettoyage, couper
l’alimentation électrique au disjoncteur et
verrouiller le panneau du disjoncteur pour éviter la
mise sous tension accidentelle. S’il n’est pas possible
de verrouiller le panneau du disconcteur, attacher
un placard ou une étiquette trés visible au panneau.
• For general ventilating use only. Do not use to
exhaust hazardous or explosive materials or vapors.
• Structural framing, installation work and electrical
wiring must be done by qualified person(s). In
accordance with all applicable codes and standards
including fire-rated construction.
• Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer’s
guideline and safety standards such as those
published by the National Fire Protection Association
(NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
• Local codes vary. Installation electrical connections
and grounding must comply with applicable codes.
In the absence of local codes, the vent should be
installed in accordance with National Electrical
Code ANSI/NFPA 70-1990 or latest edition.
CAUTION: To reduce risk of fire and to
properly exhaust air, be sure to duct air outside – Do
not vent exhaust air into spaces within walls or ceilings
or into attics, crawl spaces, or garages.
PRUDENCEIl faut prendre soin
d’installer un conduit vers l’extérieur pour réduire le
risque d’incendie et pouvoir évacuer l’air correctement.
Il ne faut pas évacuer l’air correctement. Il ne faut pas
évacuer l’air dans l’espace entre les parois d’un mur,
un plafond ou un grenier, un espace sanitaire ou un
garage.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
• IMPORTANT – Save these instructions for
local inspector’s use.
• IMPORTANT – Observe all governing codes
and ordinances.
• Note to Installer – Be sure to leave these instructions
with the Consumer.
• Note to Consumer – Keep these instructions for
future reference.
• Skill Level – Installation of this vent hood requires
basic mechanical and electrical skills.
• Completion time – 1 to 3 hours.
• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is not
covered under the Warranty.
CAUTION:
Due to the weight and size of these vent hoods and to
reduce the risk of personal injury or damage to the
product, TWO PEOPLE ARE REQUIRED FOR
PROPER INSTALLATION.
PRUDENCE
À cause du poids et de la taille de ces hottes et pour
reduire le risque de blessures et de dommages, IL FAUT
DEUX PERSONNES POUR FAIRE L’INSTALLATION
CORRECTEMENT.
WARNING:
To reduce the risk of fire or electrical shock, do not
use this range hood with any external solid-state speed
control device. Any such alteration from original
factory wiring could result in damage to the unit
and/or create an electrical safety hazard.
AVERTISSEMENT
Pour réduire le risque d’incendie ou de choc électrique,
il ne faut pas utiliser cette hotte avec un régulateur de
vitesse électronique externe. Toute modification de ce
type du branchement d’usine peute endommager
l’appareil ou créer un risque de choc électrique.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK.
3
12"
22-1/2"
35-15/16"
35-15/16"
25"
10"
Installation Instructions
PRODUCT DIMENSIONS
Model ZV36R
Model ZV48R
Model ZV30R
CONTENTS
Product Dimensions ......................................................... 3
Installation Clearances ..................................................... 4
Optional Duct Cover Accessories .................................... 4
Installation Height, Duct Cover Accessories ................... 5
Advance Planning ............................................................. 6
Power Supply .................................................................... 6
Duct Fittings ...................................................................... 7
Tools and Materials Required .......................................... 8
Remove the Packaging ..................................................... 8
Parts Provided ................................................................... 9
Step 1, Determine Ductwork and Wiring Locations .... 10
Step 2A, Install Hood Onto Wall ................................... 11
Step 2B, Install Hood Beneath Soffit ............................ 12
Step 3, Connect Ductwork ............................................. 13
Step 4, Connect Electrical .............................................. 13
Step 5, Install Duct Covers ............................................. 13
Step 6, Install Motor ....................................................... 13
Step 7, Install Filters ....................................................... 14
Step 8, Install Backguard and Shelf............................... 14
Step 9, Install Shelf Only................................................ 15
Step 10, Install Implement Rods ................................... 15
Each hood is
shipped with a
stainless steel
backguard and a
warming shelf.
Hoods may be
installed with the
shelf or backguard
alone, or with both
as shown.
Warming
Shelf
Backguard
47-15/16"
47-15/16"
25"
10"
12"
22-1/2"
12"
22-1/2"
29-15/16"
29-15/16"
25"
10"
Especificaciones del producto
Marca: | Monogram |
Categoría: | Afzuigkap |
Modelo: | ZV36RSFSS |
¿Necesitas ayuda?
Si necesitas ayuda con Monogram ZV36RSFSS haz una pregunta a continuación y otros usuarios te responderán
Afzuigkap Monogram Manuales
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
Afzuigkap Manuales
- Afzuigkap Candy
- Afzuigkap Electrolux
- Afzuigkap Samsung
- Afzuigkap ATAG
- Afzuigkap Bosch
- Afzuigkap AEG
- Afzuigkap IKEA
- Afzuigkap Panasonic
- Afzuigkap AEG Electrolux
- Afzuigkap Bauknecht
- Afzuigkap BEKO
- Afzuigkap Delonghi
- Afzuigkap Etna
- Afzuigkap Grundig
- Afzuigkap Indesit
- Afzuigkap Inventum
- Afzuigkap Miele
- Afzuigkap Siemens
- Afzuigkap Whirlpool
- Afzuigkap Zanussi
- Afzuigkap Zanker
- Afzuigkap Acec
- Afzuigkap Amica
- Afzuigkap Amana
- Afzuigkap Ardo
- Afzuigkap Arcelik
- Afzuigkap Asko
- Afzuigkap Silverline
- Afzuigkap Bartscher
- Afzuigkap GE
- Afzuigkap Orbegozo
- Afzuigkap Fisher And Paykel
- Afzuigkap Bertazzoni
- Afzuigkap Lamona
- Afzuigkap Klarstein
- Afzuigkap Fagor
- Afzuigkap Brandt
- Afzuigkap Omega
- Afzuigkap Smeg
- Afzuigkap Gorenje
- Afzuigkap Neff
- Afzuigkap Baumatic
- Afzuigkap Hoover
- Afzuigkap Saturn
- Afzuigkap KitchenAid
- Afzuigkap Teka
- Afzuigkap Progress
- Afzuigkap Cata
- Afzuigkap Gaggenau
- Afzuigkap Hotpoint-Ariston
- Afzuigkap Ignis
- Afzuigkap Kernau
- Afzuigkap Maytag
- Afzuigkap Thermador
- Afzuigkap Hanseatic
- Afzuigkap Vox
- Afzuigkap Cylinda
- Afzuigkap Bellini
- Afzuigkap Westinghouse
- Afzuigkap Vestel
- Afzuigkap ECG
- Afzuigkap Pelgrim
- Afzuigkap Blomberg
- Afzuigkap Itho
- Afzuigkap Elica
- Afzuigkap Constructa
- Afzuigkap BlueStar
- Afzuigkap Summit
- Afzuigkap Hotpoint
- Afzuigkap Midea
- Afzuigkap De Dietrich
- Afzuigkap Junker
- Afzuigkap Blaupunkt
- Afzuigkap Concept
- Afzuigkap Gram
- Afzuigkap Svan
- Afzuigkap Logik
- Afzuigkap Balay
- Afzuigkap PKM
- Afzuigkap Frilec
- Afzuigkap Rosieres
- Afzuigkap Scholtes
- Afzuigkap Profilo
- Afzuigkap KKT Kolbe
- Afzuigkap Berg
- Afzuigkap CDA
- Afzuigkap Imperial
- Afzuigkap Heinner
- Afzuigkap Schneider
- Afzuigkap Kenmore
- Afzuigkap Philco
- Afzuigkap Juno
- Afzuigkap Guzzanti
- Afzuigkap Defy
- Afzuigkap Infiniton
- Afzuigkap Blanco
- Afzuigkap Orima
- Afzuigkap Nordmende
- Afzuigkap Falmec
- Afzuigkap Haier
- Afzuigkap Rangemaster
- Afzuigkap Boretti
- Afzuigkap Ariston Thermo
- Afzuigkap Viking
- Afzuigkap Eico
- Afzuigkap Wolkenstein
- Afzuigkap Hansa
- Afzuigkap Thor
- Afzuigkap Air King
- Afzuigkap Exquisit
- Afzuigkap Proline
- Afzuigkap Euromaid
- Afzuigkap Corberó
- Afzuigkap Zelmer
- Afzuigkap Kelvinator
- Afzuigkap Soler And Palau
- Afzuigkap Zephyr
- Afzuigkap Bomann
- Afzuigkap Novy
- Afzuigkap Kuppersbusch
- Afzuigkap Continental Edison
- Afzuigkap Jenn-Air
- Afzuigkap Limit
- Afzuigkap Franke
- Afzuigkap AYA
- Afzuigkap Leisure
- Afzuigkap Nodor
- Afzuigkap Jocel
- Afzuigkap Glem Gas
- Afzuigkap Respekta
- Afzuigkap M-System
- Afzuigkap Meireles
- Afzuigkap Dacor
- Afzuigkap Falcon
- Afzuigkap Technika
- Afzuigkap Airforce
- Afzuigkap V-Zug
- Afzuigkap MPM
- Afzuigkap Becken
- Afzuigkap Esatto
- Afzuigkap Belling
- Afzuigkap Tesy
- Afzuigkap Kleenmaid
- Afzuigkap Privileg
- Afzuigkap Stoves
- Afzuigkap Faber
- Afzuigkap Ilve
- Afzuigkap Eurotech
- Afzuigkap Wolf
- Afzuigkap Thermex
- Afzuigkap Kunft
- Afzuigkap Mepamsa
- Afzuigkap Upo
- Afzuigkap Rommer
- Afzuigkap ZLine
- Afzuigkap Belion
- Afzuigkap Unox
- Afzuigkap Scancool
- Afzuigkap Sauter
- Afzuigkap Barazza
- Afzuigkap Broan
- Afzuigkap Toolcraft
- Afzuigkap Axiair
- Afzuigkap La Germania
- Afzuigkap Gutmann
- Afzuigkap Roblin
- Afzuigkap Oranier
- Afzuigkap Tisira
- Afzuigkap Bielmeier
- Afzuigkap Turbo Air
- Afzuigkap Schweigen
- Afzuigkap Apelson
- Afzuigkap Dominox
- Afzuigkap Everdure
- Afzuigkap Piccante
- Afzuigkap Kucht
- Afzuigkap Signature
- Afzuigkap Helios
- Afzuigkap JennAir
- Afzuigkap Best
- Afzuigkap Halifax
- Afzuigkap Elin
- Afzuigkap Fulgor Milano
- Afzuigkap Whispair
- Afzuigkap XO
- Afzuigkap K&H
- Afzuigkap Artusi
- Afzuigkap Robinhood
- Afzuigkap Sirius
- Afzuigkap Chef
- Afzuigkap Cosmo
- Afzuigkap Emilia
- Afzuigkap Euro Appliances
- Afzuigkap Arthur Martin-Electrolux
- Afzuigkap CENDO
- Afzuigkap Porter & Charles
- Afzuigkap Venmar
- Afzuigkap Airone
- Afzuigkap Trade-Wind
- Afzuigkap HomeCraft
- Afzuigkap CEEM
Últimos Afzuigkap Manuales
24 Septiembre 2024
24 Septiembre 2024
24 Septiembre 2024
24 Septiembre 2024
24 Septiembre 2024
24 Septiembre 2024
24 Septiembre 2024
24 Septiembre 2024
24 Septiembre 2024
24 Septiembre 2024