NL-6004P u-blox NEO-6P MD6/serial receiver roof mount
Operation manual (62447)
1. Introduction
The NL-6004P is a MD6/serial GNSS receiver with internal antenna and ublox NEO-6P GPS
module. This module allows a positioning accuracy of under one metre through a combination of
PPP (Precision Point Positioning) and SBAS technologies. The MD6/serial interface enables
connection to a notebook, UMPC, tablet or car PC. The receiver bottom side is rubberized and
magnetic, which allows for universal positioning. Thanks to its compact design and its high
precision positioning technology, it is the ideal companion at work and at leisure.
Contents*
1x Navilock NL-6004P
1x 8 cm CD ROM including operation manual
* Before using the device, please make sure that all the parts are included in the package. If any
parts are missing or damaged, please contact your dealer immediately.
Important health and safety information
When using this product, take the following precautions in order to avoid possible damages and legal consequences. Always follow all
safety and operation manuals exactly and keep them for future reference. Observe all warnings in the operation manual and on the
product. In order to avoid injuries, electrocution, fire and damages to the product, observe the following precautions:
ELECTRIC SECURITY
This product is designed for operation with power supply via the USB or PS/2 port. Any other operation mode can be dangerous and
may void the warranty claims for this product. This unit contains an internal back-up battery.
NOTE: RECYCLE OR DISPOSE OF USED BATTERIES OR RECHARGEABLE BATTERIES IN
ACCORDANCE WITH ALL APPLICABLE REGULATIONS AND THE INSTRUCTIONS INCLUDED
WITH THE PRODUCT.
PRECAUTIONS REGARDING DIRECT SUNLIGHT
Make sure the unit is not exposed to very high humidity and temperatures. Never leave the unit, the battery or the rechargeable
battery for an extended period in a vehicle or plate, where the temperature can increase to over 60°C (140°F), for example on the
dashboard of a car, the window sill or behind a pane of glass, which is directly exposed to the sun or very strong UV light. Otherwise
the unit or the vehicle may be damaged, and the battery or the rechargeable battery may overheat.
Damages requiring repairs
Disconnect the unit from the AC supply in the following cases; also disconnect the rechargeable battery and contact an authorized
repair man or your dealer.
Liquid or an object has entered the product.
The product has fallen down or was damaged.
There are visible signs of overheating.
• When operated normally, the product does not function flawlessly.
Avoid using the unit directly after strong temperature changes.
If the unit is exposed to strong temperature and humidity fluctuations, condensation can form in the unit. In order to avoid damage to
the unit, please wait until the condensation has dried off before using the unit.
NOTE: If you bring the unit from a cold to a warm environment, or vice versa, first let it get
accustomed to the new temperature before turning it on.
2. Starting operation
You may connect the NL-6004P either to the serial interface of your PC using an MD6 to DB9
adapter cable, or to the USB interface of your PC using an MD6 to USB adapter cable.
MD6 to DB9: http://www.navilock.de/produkte/G_61265/merkmale.html?setLanguage=en
MD6 to USB: http://www.navilock.de/produkte/G_61264/merkmale.html?setLanguage=en
All values for the serial connection via DB9, such as COM Port, Baud rate etc., result from the
settings of this interface on your PC.
Use the following guide for USB adaptation:
Plug the USB cable into a free USB connector of your notebook, etc. Your Windows operating
system then detects the NL-6004P and attempts to install a driver. When automatic detection
does not work, install the Prolific USB driver from the supplied CD under the Installation -> NL-
6004P menu item.
Please restart your computer after the installation is completed. Afterwards, the GPS COM Port
will be available in the device manager under connections. Set this port in your navigation or
route planner software. Do not simultaneously use any other program accessing this COM
Port.
3. LED indicator
this receiver comes without LED
4. Application environment
The NL-6004P can be used as a MD6/Serial GPS receiver under Windows CE/2000/XP/Vista/7/8.
The corresponding driver is available on the CD-ROM.
5. Functional test with u-center 7.xx
Download u-center from:
http://www.navilock.de/produkte/G_60095/software.html?setLanguage=en. Install the u-center
software on your unit. Select the version suitable for your system. U-center is a pure test
program and cannot be used for navigation or orientation. It must always be closed after the
test. It blocks the COM port and does not allow any access of the navigation or route software
to the COM port. It also serves for updating the Assist GPS data and switching to EGNOS or
WAAS etc.