Netgear ANT224 Manual de Usario

Lee a continuación 📖 el manual en español para Netgear ANT224 (2 páginas) en la categoría No categorizado. Esta guía fue útil para 8 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/2
)NSTALLATION'UIDE
NETGEAR ProSafe Indoor/Outdoor 10 dB 2x2 Directional Antenna ANT224D10
Package Contents
NETGEAR ProSafe Indoor/Outdoor 10 dB 2x2
Directional Antenna ANT224D10
2 lightning arrestors with 30 cm low-loss cables
2 reverse N/SMA adapters
Wall mount and pole mounting hardware
Installation Guide (this guide) and Warranty/
Support card
Ground cable is not included but is required for outdoor
installation. The grounding cable must be equivalent or
better than: AWG 10, UL 1015, Stranded, 600 V, 105 C,
green or green/yellow insulation, 2 clip of 5.5 mm inner
diameter cramped at both ends, cable no longer than 5
meters. Antenna cables are not provided, but are
required to connect to an access point (AP).
Note: For optimal results in extending wireless range, consult a qualified professional
installer service.
Antenna Placement and Location
Antenna placement dramatically affects potential coverage. Follow these guidelines to
maximize coverage:
Place the antenna in a vertical position, connector toward the bottom.
Minimize the obstructions in the front of the antenna. There should be a good visual line
of sight and maximum open space between the antenna and the other antenna(s).
Outdoor point-to-point applications are bridging, repeater mode, or building-to-
building. Mount the antenna on the top of a building on a pole or on an external wall.
For building-to-building transmission you can also install antennas indoors within 10 ft.
of clean windows (no metal coating) in both buildings facing each other. Account for
30-70 % less range than outdoors.
Indoor point to multipoint Warning: The antenna is not omnidirectional and is not
suitable for low ceilings, partial obstructions, walls, cubicles, or when large metal
objects are present.
For best performance with indoor installation, use a short cable between the antenna
and the wireless device. Install the antenna so that it is a minimum of 50 cm (20 in.)
away from people.
First, Mount the Antenna
Then, Connect the Antenna
1. Turn off your wireless access point.
2. This step is only for outdoor installation. For indoor installation, go to step 3.
a. Connect a 30 cm cable (included) to the antenna and to an RF port on the lightning
arrestor.
b. Connect the grounding cable (not included) from the lightning arrestor to the
ground of the building.
Warning: The lightning arrestor and appropriate ground cable must be used for
outdoor installation. NETGEAR does not assume any responsibility in case of
hazard resulting of non-compliance.
c. Screw the N/SMA reverse adapter onto the lightning arrestor RF port.
3. Connect a NETGEAR cable ACC-10314-01, 03,or 04 (sold separately) to the adapter.
4. Locate the primary detachable antennas on the wireless AP. Remove the antennas and
connect the other end of the NETGEAR cable to this port.
5. Reconnect your wireless device to the network and turn it on.
Wall Mounting Pole Mounting
Antenna faces coverage
area. Indoors, put it 2M+
from the floor and above
cubicles. Do not install in
IT rooms or rooms with
metal partitions.
Indoor Connection
Outdoor Connection
Access Point
NETGEAR antenna
cable (sold separately)
N/SMA Adapter
Antenna
Access Point
Lightning
Arrestor
Grounding cable
Ethernet
N/SMA
Adapter
30 cm NETGEAR low-
loss antenna cable(not provided)
Antenna
NETGEAR antenna cable
(sold separately)
ANT224D10 IG.fm Page 1 Monday, July 20, 2009 9:43 AM
July 2009
This symbol was placed in accordance with the European Union Directive 2002/96 on the Waste
Electrical and Electronic Equipment (the WEEE Directive). If disposed of within the European Union,
this product should be treated and recycled in accordance with the laws of your jurisdiction implementing
the WEEE Directive.
© 2009 by NETGEAR, Inc. All rights reserved. NETGEAR and the NETGEAR logo are registered trademarks of
NETGEAR, Inc. in the United States and/or other countries. Other brand and product names are trademarks or
registered trademarks of their respective holders. Information is subject to change without notice.
Technical Support
Thank you for selecting NETGEAR products. Locate the serial
number on the label of your product and use it to register your
product at www.NETGEAR.com/register. Registration is
required before you can use our telephone support service.
Registration via our website is strongly recommended.
Go to http://kbserver.netgear.com for product updates and Web
support. For Warranty and Customer Support information see
the Customer Support card that came with you product.
Antenna Specifications 30 cm Cable Lightning Arrestor Specifications
Frequency range 2.4~2.5GHz Frequency range 0 to 3 GHz Frequency range DC~6GHz
Impedance 50 ohm VSWR 1.5 max. VSWR 1.5 max.
VSWR 2.0: 1 max. Cable type HPF 195 Harbour Industries Insertion loss less 0.9dB
Isolation at least 20 dB Transmission loss 2.2 dB max @ 2.4 – 2.5 GHz DC Spark Over Voltage
100V/S
184-276V
HPBW/H 33° Connector type 2 N type male reverse Gas Tube Insulation
Resistance At 100Vdc
10 G Ohm max.
HPBW/V 32° Max. working voltage 250 Vrms min. Impedance 50 Ohms
Polarization Linear; vertical Minimum bend radius 25 mm (1 in.) Insulation resistance 2,000 Megohms
Power handling 1 W Jacket FRPBC Black, 5 mm (0.195 in.)
diameter
Capacitance 1MHz Pf
current
less 1
Peak gain 10 dBi Recommended
coupling nut torque
229 mm.kg* to 559 mm.kg*
(4.1 in.lbs to 10.0 in.lbs)
DC Holdover Voltage
per ITU-T K.12
135V
Temperature Operating –30 to 80° C (–22 to176° F)
Storage –40 to 85° C (–40 to185° F)
Coupling nut
retention force
22 kg* (50 lbs.) min. Connectors N type female reverse
Humidity 95% RH Connector body and
contact
Brass Per JIS H3250 C3604 BD, plated Temperature 40~85° C (–40 to 185° F)
Radome material ABS Insulation PTFE Fluorocarbon per ASTM D 1710 Water proof Rain resistant
Dimensions (l x w x h) 240 x 240 x 40mm
(9.45 x 9.45 x 1.57 in)
Temperature/RH Storage and operating –40 to 75° C
(–40 to167° F)/ 20 to 95% RH
RoHS compliant Yes
Weight 700 gf (24.7 oz.) Water proof Rain resistant
Connector N plug reverse x 2
Horizontal Radiation Patterns Vertical Radiation Patterns
Statement of Conditions
In the interest of improving internal design, operational function, and/or reliability, NETGEAR reserves
the right to make changes to the products described in this document without notice. NETGEAR does
not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s)
described herein.
Federal Communications commission (FCC) Compliance Notice: Radio Frequency
Notice
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired
operation.
To comply with FCC regulations, the ANT32405 should only be used with devices that have been FCC
approved for use with the NETGEAR ANT32405. Check the NETGEAR website at
http://tools.netgear.com/legal/fcc_antennas.html for an updated list of FCC approved devices.
Note: This equipment has been tested and found to comply with the limits for Class B digital devices,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures: (1) Reorient or relocate the receiving
antenna; (2) Increase the separation between the equipment and receiver; (3) Connect the equipment to
an outlet or circuit different from that to which the receiver is connected; (4) Consult the dealer or an
experienced radio/TV technician for help.
FCC and EU Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
To avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the
antenna must be less than 20 cm (8 inches) during normal operation.
This device should not be co-located with other transmitters.
For EU, use of any antenna requires careful planning and extra considerations to comply with EU
emissions and health standards and regulations. Antenna installation must comply with the maximum
level authorized by each country.
ANT224D10 IG.fm Page 2 Monday, July 20, 2009 9:43 AM

Especificaciones del producto

Marca: Netgear
Categoría: No categorizado
Modelo: ANT224

¿Necesitas ayuda?

Si necesitas ayuda con Netgear ANT224 haz una pregunta a continuación y otros usuarios te responderán




No categorizado Netgear Manuales

No categorizado Manuales

Últimos No categorizado Manuales