OPERATING & ASSEMBLY INSTRUCTION
®
powerCON Locking 3 pole Power Connector
R
Page 1BDA 604
A. OPERATING INSTRUCTION
IMPORTANT SAFETY INSTRUCTION:
The powerCON system is certified as connector without breaking capacity according IEC 61984 / VDE 0627.
In this standard the term connector (without breaking capacity) refers to components which in normal use are not to
be engaged or disengaged when under load or live.
Connector Combination & Keyways:
With the two non-interchangeable types of connectors (A type and B type) it is impossible to produce a short circuit. Mating
connectors (combination) are identified by mechanical keyways and by color.
A type (color coding blue)
POWER IN
B type (color coding gray)
POWER OUT
L
IE C
HTEN
STEIN
LIE
CH
TENS
TEIN
B. ASSEMBLY INSTRUCTION
Place the bushing (1) and the chuck (2) over
the cable.
White chuck (a): 6.0 - 11.0 mm [0.236 - 0.433”]
Black chuck (b): 9.5 - 15.0 mm [0.374 - 0.59”]
VDE: 9.5 - 14.0 mm [0.374 - 0.551”]
Prepare the cable as shown.
Cable O.D.: 6.0 - 15.0 mm [0.236 - 0.59”]
2
Wire size: 2.5 mm (AWG 14)
Insert the wire into the terminals and fasten
the clamping device with a POZIDRIV® #1,
max. Torque 0.5 Nm (0.37 lb-ft).
B
A
B
[0.32"]
8 mm
[0.787”]
20 mm
[0.9”]
PE 23 mm
NAC3FCA* NAC3FCB*
C
max. Torque Value 0.5 Nm
POZIDRIV® #1
N L
WIRING C
ð
or
1.
2.
b
a
A