Panasonic PAW-PACR4 Manual de Usario

Lee a continuación 📖 el manual en español para Panasonic PAW-PACR4 (9 páginas) en la categoría aire acondicionado. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/9
1
Operation Instruction PAW-PACR4
Operation Instruction PAW-PACR4
Author: Marco Bauer
Date: 22.01.2023
Status: 1.0.2
2
Operation Instruction PAW-PACR4
Contents
2 BASICS .............................................................................................................................................3
2.1 MENU STRUCTURE ........................................................................................................................3
2.2 MENU NAVIGATION ......................................................................................................................5
2.3 SETTING VALUES ...........................................................................................................................5
2.4. DEFAULT DISPLAY .........................................................................................................................6
3 PARAMETERS ...................................................................................................................................6
3.1 TEMPERATURE LIMIT 1..................................................................................................................6
3.2 TEMPERATURE LIMIT 2..................................................................................................................6
3.4 TEMPERATURE LIMIT 4..................................................................................................................6
3.5 ALARMLIMIT .................................................................................................................................6
3.6 HYSTERESIS ...................................................................................................................................6
3.7 ROTATION TIME ............................................................................................................................7
3.8 OPERATING MODE ........................................................................................................................7
3.9 LANGUAGE ....................................................................................................................................7
3.9 RESET TIME ...................................................................................................................................7
4 PROCESS DATA .................................................................................................................................7
4.1 AVAILABLE AGGREGATES ..............................................................................................................8
4.2 CURRENT UNITS ............................................................................................................................8
5 CURRENT FAULT MESSAGES .............................................................................................................8
5.1 THE FOLLOWING ERROR CODES ARE DISPLAYED: ..........................................................................8
3
2 BASICS
The user interface is designed as an OLED display with a rotary wheel and push button.
After switching on the device, an automatic system initialization is carried out, in which all four
air conditioning units are activated one after the other by the control. In a first step, only devices
that return an "active message" via digital inputs, within a defined period, are used for
temperature control for the period in which the controller is active. In case no digital input
response is received, a second step Modbus slave addresses 1 – 4 will be activated and checked
for “active message” via Modbus communication. The Modbus slave addresses are fixed and
cannot be changed.
The menu is navigated using the rotary wheel, the push button located in the rotary wheel and
the "back button" located next to it.
2.1 MENU STRUCTURE
Overview Parameter
Process data
Alarms
Temperaturelimit 1
24.0°C
Temperaturelimit 2
2
8
.0°C
T room 23.2 °C
T set
24.0
Actual Temp.
23.2 °C
Avail. Aggr.
0-1-1-0
Act. Aggr.
0
-
1
-
1
-
0
Current Mode
cooling
Act. Message
Err: 11
Temperaturelimit 3
30.0°C
Temperaturelimit 4
32.0°C
Alarmlimit
40.0°C
Hysteresis
1.0°C
Rotation Time
1.
2 h
Operation mode
cooling
Language
English
Reset time
0.1 h