Perlick BC96 Manual de Usario

Lee a continuación 📖 el manual en español para Perlick BC96 (5 páginas) en la categoría Refrigerador. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/5
Installation
& Operation Manual
Flat Top Bottle Cooler
BC Series
Form No. Z2295
Rev. 07.06.2017
C
US
BC72 shown
Flat Top Bottle Coolers Installation & Operation Manual
Printed in USA 2
MODEL NUMBERS BC24 BC36 BC48/BC48LT BC60/BC60LT BC72/BC72LT BC96
LENGTH (mm) 24” (610) 36” (915) 48” (1219) 60” (1524) 72” (1828) 96” (2438)
INTERIOR CU. FT. (m
3) 3.75 (0.10) 7.83 (0.22) 11.68 (0.33) 15.53 (0.44) 19.38 (0.55) 27.08 (0.77)
CASE CAPACITY (12 bottles) 5.5 9.75 17.2 21 28.3 41
CASE CAPACITY (12 cans) 7.0 16 25 30 36 58
CONDENSING UNIT H.P. 1/5 1/5 1/4 1/4 1/3 1/3
AMPS 3.2 3.0 5.2 7.0 6.9 7.6
SHIPPING WEIGHT Lbs. (kg.) 190 (86) 245 (111) 300 (136) 353 (160) 405 (184) 515 (235)
INTERIOR All models have stainless steel walls and oor.
EXTERIOR
Choice of black, stainless steel and all stainless.
Black Option: Front and ends are black vinyl coated steel, back and bottom are galvanized.
Stainless Steel Option: Front and ends are stainless steel, back and bottom are galvanized.
All Stainless Option: Front, ends, back and bottom are all stainless steel.
TEMPERATURE
(Approx. factory settings) 38ºF/Standard Model. 30ºF Low-Temp Model
DOORS (Siding) Stainless steel top and bottom pans. Die cast handle. Option locks.
ELECTRICAL 115V, 60Hz, 1 Phase. Furnished with 6 foot rubber plug-in cord (115V model only). Also available in 230V, 50Hz, 1 phase AC.
PLUMBING No drain required. Condensate evaporates automatically.
INSULATION 2 inch foamed-in-place polyurethane insulation.
REFRIGERATION R134a capillary tube/type with hermetric condensing unit. Pulls out for service and cleaning.
VENTILATION 2’ model is front vented, all other models require 2” clearance from wall on either left end or back of cabinet for proper air ow.
OPTIONAL ACCESSORIES
• Floor racks • Casters • Bottle opener and receiver • Interior light
• Bin dividers • Speed rails • Wine temperature (specify red or white)
• Interior light kits • Adjustable legs • Roller basket shelving • Door locks
JOB
AREA
ITEM NO.
MODEL NO.
BC24 SERIES
BC36 SERIES
BC48 SERIES
BC48LT SERIES
BC60 SERIES
BC60LT SERIES
BC72 SERIES
BC72LT SERIES
BC96 SERIES
C
US
BC72 shown
* BC36 Model Only
* Shown with optional opener and receiver.
BC24 shown
Flat Top Bottle Coolers Installation & Operation Manual
Printed in USA 5
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice.
HOW TO OPERATE - FLAT TOP BOTTLE COOLERS
Temperature Control
An adjustable temperature control is located inside
the Bottle Cooler on the evaporator fan panel
assembly. It is factory set at approximately 38˚F
for standard refrigeration and approximately 30˚F
for low temperature models. Make adjustments as
detailed below to attain the desired temperature.
NOTE: A temperature setting that is too low will
not allow enough condensing unit “o󰀨” time to
maintain a frost-free coil.
Colder Temperatures: Turn the adjusting
screw clockwise (to the right)
Warmer Temperatures: Turn the adjusting
screw counterclockwise (to the left).
Temperature Control “OFF”: Turn the
adjusting screw completely counterclockwise
to the “O” position until a “click” is noted.
The condenser fan motor turns o󰀨 and on with
compressor. The evaporator fan motor runs
continuously.
Cleaning the Condenser
■ The condenser (located behind the from
grille) should be inspected every 30 days,
and cleaned, if necessary. Failure to
keep the condenser clean will cause a loss
in condensing unit e󰀩ciency, or compressor
failure.
Cleaning the Doors
■ Doors should be periodically removed from
the cabinet and inspected for a buildup of
foreign materials, such as syrups, beer, etc.
Buildups on the underside of the doors,
along with the cabinet breaker strips on
which they ride, will cause them to bind,
and therefore, not function as designed. If
dirty, these surfaces should be cleaned with
a mild detergent and water and then coated
with a silicone lubricating material. Aerosol
silicone sprays can be obtained locally at
most hardware or automotive stores.
To remove doors:
■ With door closed, lift it upward by its handle
and slide forward until doors clears the
cabinet top. Use the reverse procedure to
reinstall the doors.
Cleaning the Cabinets
■ Use a damp cloth with a mild detergent and
water to clean the inside and outside of the
cabinet. Dry thoroughly. Do not allow cleaning
agents or large amounts of water to go down
the drain. Use an acceptable stainless steel
polish to clean all stainless steel surfaces.
Never use steel wool or scouring pads to clean
stainless steel.
Avoiding Stainless Steel Corrosion
Corrosion can be prevented by following product
cautions, cleaning instructions and avoiding use
of certain chemicals or objects which will cause
stainless steel corrosion.
STAINLESS STEEL ENEMY
■ Steel wool or steel scouring pads
■ Cherry/Orange/Olive juice
■ Chlorine Bleach
■ Sharp Objects

Especificaciones del producto

Marca: Perlick
Categoría: Refrigerador
Modelo: BC96

¿Necesitas ayuda?

Si necesitas ayuda con Perlick BC96 haz una pregunta a continuación y otros usuarios te responderán




Refrigerador Perlick Manuales

Refrigerador Manuales

Últimos Refrigerador Manuales