Pioneer CA-ECO-UNI.003 Manual de Usario

Pioneer No categorizado CA-ECO-UNI.003

Lee a continuación 📖 el manual en español para Pioneer CA-ECO-UNI.003 (2 páginas) en la categoría No categorizado. Esta guía fue útil para 4 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/2
CA-ECO-UNI.003
VOLTAGE STABILIZER 7Vdc-12Vdc
Technical Description:
Min Max
Operating Input voltage range 7 Vdc 12 Vdc
Operating Output voltage 12 Vdc*
Permanent Out current 5A dc continuous Up to 10A for 6 seconds
Key Out current 100 mA
Standby consumption < 5 mA
Key In consumption < 1 mA
Max output power 120 W
Efficiency - 90%
Overcurrent/Short protection YES (EXT FUSE)
Polarity reversal protection YES (EXT FUSE)
Operating Temperature -40°C ÷ +85°C
Dimensions 75x25x55mm
Weight 300g
Certifications E24(NSAI) approved according to R10-04
*The circuit only operates in a range of input voltage going
from 7V to 12V. Outside this range the circuit stops to
operate and the output voltage follows the input voltage
minus 0.6V. The Key Out signal is conditioned by the status
of the Key In and by the operating state of the regulator (see
graphics on page 2), and it is available as a signal for the car
stereo.
This harness allows to connect:
-YELLOW/RED: 7÷12Vdc input (Permanent In)
- BLUE: 7÷9Vdc input ignition key (Key In)
- YELLOW: 12Vdc output (Permanent Out)
- RED: 12V output key (Key Out)
- BLACK + BLACK: GND (both internally shorted)
The manufacturer will reserve to make technical changes to the device without notice.
All installation work must be performed by a qualified professional installer only.
The manufacturer / dealer is not liable for any kind of incidental or indirect damages.
1/2 Version 3.0 Written on 25 10 2017
10R-041548
Functional charts
Note: Fall times is purely indicative.
The charts show the default behavior; customized versions
are available with regard to the management of the timing of
the outputs.
The manufacturer will reserve to make technical changes to the device without notice.
All installation work must be performed by a qualified professional installer only.
The manufacturer / dealer is not liable for any kind of incidental or indirect damages.
2/2 Version 3.0 Written on 25 10 2017
12345678910
0
2
4
6
8
10
12
KEY IN
PERMANENT IN
KEY OUT
PERMANENT OUT
Time [s ]
Voltage [V]
0 1 2 3 4 5 6 7 8 9 10 11
0
2
4
6
8
10
12
14
Time [s ]
Voltage [V]
12345678910
0
2
4
6
8
10
12
14
Time [s ]
Voltage [V]
12345678910
0
2
4
6
8
10
12
14
Time [s ]
Voltage [V]
1 2 3 4 5 6 7 8 9 10
0
2
4
6
8
10
12
14
Time [s ]
Voltage [V]

Especificaciones del producto

Marca: Pioneer
Categoría: No categorizado
Modelo: CA-ECO-UNI.003

¿Necesitas ayuda?

Si necesitas ayuda con Pioneer CA-ECO-UNI.003 haz una pregunta a continuación y otros usuarios te responderán




No categorizado Pioneer Manuales

No categorizado Manuales

Últimos No categorizado Manuales