Planet IPOE-260 Series Manual de Usario

Planet No categorizado IPOE-260 Series

Lee a continuación 📖 el manual en español para Planet IPOE-260 Series (2 páginas) en la categoría No categorizado. Esta guía fue útil para 3 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/2
- 1 -
- 2 -
- 3 -
- 4 -
- 5 -
- 6 -
- 7 -
- 8 -
1. Package Contents
Thank you for purchasing PLANET Industrial 2-port 10/100/1000T
802.3at PoE+ Injector Hub, IPOE-260/IPOE-260-12V. In the
following section, the term “Industrial PoE+ Injector Hub”
means the IPOE-260 or IPOE-260-12V.
Open the box of the Industrial PoE+ Injector Hub and carefully
unpack it. The box should contain the following items:
Industrial PoE+
Injector Hub x 1 User’s Manual x 1 Wall-mount Kit x 1
DIN-rail Kit x 1 RJ45 Dust Caps x 4
If any of these are missing or damaged, please contact your dealer
immediately.
Power
Consumption
(Ethernet Full
Loading)
Max. 2 watts/6.8 BTU
(Power on without
any connection)
Max. 80 watts/272.9
BTU (Full loading
with PoE function)
Max. 4 watts/13.6
BTU (Power on
without any
connection)
Max. 80 watts/272.9
BTU (Full loading with
PoE function)
Dimensions
(W x D x H) 30 x 70 x 105 mm
Weight 280g 280g
Enclosure IP30 metal case
Installation DIN-rail kit and wall-mount kit
ESD Protection 6KV
EFT Protection 6KV
Power over Ethernet
PoE Standard IEEE 802.3at Power over Ethernet Plus/
mid-span PSE
PoE Power Output
48V DC input: Per
PoE port max. 32
watts
56V DC input: Per
PoE port max. 36
watts
Per port 54V DC,
max. 36 watts
PoE Power Supply
Type Mid-span
Power Pin
Assignment 4/5 (+), 7/8 (-)
3.4 Wiring the Power Inputs
The terminal block connector on the top panel of Industrial PoE+
Injector Hub is used for two DC redundant power inputs. Please
follow the steps below to insert the power wire.
Caution
When performing any of the procedures like inserting
the wires or tightening the wire-clamp screws, make
sure the power is OFF to prevent from getting an
electric shock.
1. Insert positive and negative DC power wires into contacts 1 and
2 for POWER 1, or contacts 3 and 4 for POWER 2.
V1+
PWR1
V2+ V2
PWR2
DC Input:
48-56V
, 1.6A max.
1 2 3 4
2. Tighten the wire-clamp screws for preventing the wires from
loosening.
1234
Power 1 Power 2
+ - + -
3. Hardware Introduction
3.1 Switch Front Panel
The front panels of the Industrial PoE+ Injector Hubs consist of
Ethernet interfaces and LED indicators.
Front View
P1 P2
Ethernet
Ethernet
802.3at PoE+
802.3at PoE+
P1 P2
Ethernet
Ethernet
802.3at PoE+
802.3at PoE+
Data port 1
PoE port 1
Data port 2
PoE port 2
Figure 1: Figure 2:
IPOE-260 Front View IPOE-260-12V Front View
2.ProductSpecications
Model IPOE-260 IPOE-260-12V
Hardware Specications
Copper Ports
2 pair 10/100/1000BASE-T RJ45 auto-MDI/
MDI-X ports:
Data input port 1 and PoE output port 1
Data input port 2 and PoE output port 2
Connector Removable 4-pin terminal block
Pin 1/2 for Power 1; Pin 3/4 for Power 2
LED Indicator
System:
Power 1 (Green),
Power 2 (Green),
PoE Port:
802.3at PoE+ x 2 (Green + Orange)
Network Cable
Twisted-pair cable up to 100 meters (328ft)
10BASE-T: 4-pair UTP Cat. 3, 4, 5, 5e, 6
100BASE-TX: 4-pair UTP Cat. 5, 5e, 6
1000BASE-T: 4-pair UTP Cat. 5e, 6
Data Rate 10/100/1000Mbps
Power
Requirements
48~56V DC,
redundant power
with reverse polarity
protection function.
12~56V DC,
redundant power
with reverse polarity
protection function.
PoE Power Budget
(max.)
72 watts@48~56V
DC input
60W @12~23V DC
input
72W @24~56V DC
input
Number of devices
that can be
powered
2
Standards Conformance
Regulatory
Compliance FCC Part 15 Class A, CE
Stability Testing
IEC 60068-2-32 (free fall)
IEC 60068-2-27 (shock)
IEC 60068-2-6 (vibration)
Standards
Compliance
IEEE 802.3 Ethernet
IEEE 802.3u Fast Ethernet
IEEE 802.3ab Gigabit Ethernet
IEEE 802.3at Power over Ethernet Plus
Environment
Temperature Operating: -40~75 degrees C
Storage: -40~75 degrees C
Humidity Operating: 5~90% (non-condensing)
Storage: 5~90% (non-condensing)
3.2 LEDDenition:
LED Color Function
P1 Green Lights to indicate power input 1 has power.
P2 Green Lights to indicate power input 2 has power.
802.3at
PoE+
PoE-in-Use
Green Lights to indicate the device is providing
PoE power to 802.3af PD.
Green +
Amber
Lights to indicate the device is providing
PoE power to 802.3at PD.
3.3 Switch Upper Panel
The upper panels of the Industrial PoE+ Injector Hubs consist of
one terminal block connector within two power inputs.
V1+
PWR1
V2+ V2
PWR2
DC Input:
48-56V
, 1.6A max.
1 2 3 4
Figure 3: IPOE-260 Top View
V1+
PWR1
V2+ V2
PWR2
DC Input:
12-56V
, 6A max.
1 2 3 4
Figure 4: IPOE-260-12V Top View
Note
The wire gauge for the terminal block should be in the
range between 12 and 24 AWG.
3.5 Grounding the Device
Users MUST complete grounding wired with the device; otherwise,
a sudden lightning could cause fatal damage to the device.
V1+
PWR1
V2+ V2
PWR2
DC Input:
48-56V
, 1.6A max.
1 2 3 4
Earth Ground
Note
EMD (Lightning) DAMAGE IS NOT CONVERED UNDER
WARRANTY.
- 9 -
- 10 -
- 11 -
- 12 - - 13 - - 14 -
4. Installation
This section guides you to installing the Industrial PoE+ Injector
Hub on the DIN rail and wall. Please read this chapter completely
before continuing.
Note
In the installation steps below, this manual uses
PLANET IGS-801 8-port Industrial Gigabit Switch as
an example. The steps for PLANET Industrial Slim-type
Switch, Industrial Media/Serial Converter and Indus-
trial PoE devices are similar.
4.1 DIN-rail Mounting Installation
1
2
4.2 Wall-mount Plate Mounting
5. Three-View Diagram
IPOE-260
104.00
30.00
70.00
18.00
91.00
28.00
48.80
18.00
18.00
Top View
Side View Front View
Mounting Kit
Mounting Kit
DIN-Rail Kit
Side View Rear View
Unit: mm
Bottom View
P1 P2
Etherne t
Etherne t
802.3a t PoE+
802.3a t PoE+
V1+
PWR1
V2+ V2
PWR2
DC npu I t:
48-5 6V
, A 1.6 max .
Figure 5: IPOE-260 Three-View Diagram
4.3 Side Wall-mount Plate Mounting
Caution
You must use the screws supplied with the wall-
mounting brackets. Damage caused to the parts by
using incorrect screws would invalidate your warranty.
IPOE-260-12V
104.00
30.00
70.00
18.00
91.00
28.00
48.80
18.00
18.00
Top View
Side View Front View
Mounting Kit
Mounting Kit
DIN-Rail Kit
Side View Rear View
Unit: mm
Bottom View
P1 P2
Etherne t
Etherne t
802.3a t PoE+
802.3a t PoE+
V1+
PWR1
V2+ V2
PWR2
DC npu I t:
12-5 6V
, A 6 ma x.
Figure 6: IPOE-260-12V Three-View Diagram
Customer Support
Thank you for purchasing PLANET products. You can browse our
online FAQ resource on PLANET web site rst to check if it could
solve your issue. If you need more support information, please
contact PLANET support team.
PLANET online FAQs:
http://www.planet.com.tw/en/support/faq
Support team mail address:
support@planet.com.tw
Copyright © PLANET Technology Corp. 2019.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
FCC Warning
This device has been tested and found to comply with the limits
for a Class A digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used
in accordance with the Instruction manual, may cause harmful
interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own
expense
WEEE Warning
To avoid the potential eects on the environment and
human health as a result of the presence of hazardous
substances in electrical and electronic equipment, end
users of electrical and electronic equipment should
understand the meaning of the crossed-out wheeled bin symbol. Do
not dispose of WEEE as unsorted municipal waste and have to
collect such WEEE separately.

Especificaciones del producto

Marca: Planet
Categoría: No categorizado
Modelo: IPOE-260 Series

¿Necesitas ayuda?

Si necesitas ayuda con Planet IPOE-260 Series haz una pregunta a continuación y otros usuarios te responderán




No categorizado Planet Manuales

No categorizado Manuales

Últimos No categorizado Manuales