Planet ISW-1600T Manual de Usario

Lee a continuación 📖 el manual en español para Planet ISW-1600T (2 páginas) en la categoría No categorizado. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/2
- 1 -
- 2 -
- 3 -
- 4 -
- 5 -
- 6 -
- 7 -
- 8 -
Industrial Multi-port 10/100TX
Fast Ethernet Switch
ISW-1600T/IFGS-1822TF
Version 1.0
User's Manual
2.ProductSpecications
Product ISW-1600T IFGS-1822TF
Hardware Specications
Fast Ethernet
Copper Ports
16 10/100BASE-TX RJ45 auto-MDI/MDI-X
ports
Gigabit Ethernet
Copper Ports --
Two
10/100/1000BASE-T
RJ45 auto-MDI/MDI-X
ports
(shared with Port-17
and Port-18)
SFP Slots --
Two 1000BASE-SX/
LX/BX SFP interfaces
(shared with Port-17
and Port-18)
Switch Architecture Store-and-Forward
Switch Fabric 3.2Gbps
(non-blocking)
7.2Gbps
(non-blocking)
Throughput
(packet per
second)
2.38Mpps@ 64 bytes 5.36Mpps@ 64 bytes
Address Table 16K entries, automatic source address
learning and aging
Shared Data Buer 4Mbits
3.2 LEDDenition:
System
LED FunctionColor
DC1 Lights to indicate DC power input 1 has power.Green
DC2 Lights to indicate DC power input 2 has power.Green
Fault Red Lights to indicate that AC or DC power has
failed.
Per 10/100BASE-TX Port
LED FunctionColor
LNK/
ACT Green
Lights to indicate the link through that port is
successfully established.
Blinking to indicate that the switch is actively
sending or receiving data over that port.
O to indicates that the port is linked down.
100
Speed Amber
Lights to indicate that the port is operating at
100Mbps.
O to indicates that the port is operating at
10Mbps.
O to indicates that the port is linked down.
Standards
Compliance
IEEE 802.3 10BASE-T
IEEE 802.3u
100BASE-TX
IEEE 802.3x ow
control and back
pressure
IEEE 802.1p Class of
Service
IEEE 802.3az Energy
Ecient Ethernet
(EEE)
IEEE 802.3 10BASE-T
IEEE 802.3u
100BASE-TX
IEEE 802.3ab Gigabit
1000T
IEEE 802.3z Gigabit
SX/LX
IEEE 802.3x ow
control and back
pressure
IEEE 802.1p Class of
Service
IEEE 802.3az Energy
Ecient Ethernet
(EEE)
Environment
Operating
Temperature -40 ~ 75 degrees C
Storage
Temperature -40 ~ 85 degrees C
Humidity 5 ~ 95% (non-condensing)
1. Package Contents
Thank you for purchasing PLANET Industrial Multi-port 10/100TX
Fast Ethernet Switch, ISW-1600T/IFGS-1822TF. In the following
sections, the term means the “Industrial Ethernet Switch”
ISW-1600T or IFGS-1822TF.
Open the box of the Industrial Ethernet Switch and carefully
unpack it. The box should contain the following items:
Industrial Ethernet
Switch x 1
User’s Manual x 1 Wall-mount Kit x 1
RJ45 Dust Cap x 16 DIN-rail Kit SFP Dust Cap x 2
(IFGS-1822TF only)
If any of these are missing or damaged, please contact your dealer
immediately; if possible, retain the carton including the original
packing material, and use them again to repack the product in case
there is a need to return it to us for repair.
Flow Control IEEE 802.3x pause frame for full-duplex
Back pressure for half-duplex
ESD Protection 6KV DC
Enclosure IP30 metal case
Installation DIN-rail kit and wall-mount kit
Connector
Removable 6-pin terminal block for power
input
Pin 1/2 for Power 1, Pin 3/4 for fault alarm,
Pin 5/6 for Power 2
Alarm One relay output for power failure. Alarm
relay current carry ability: 1A @ 24V DC
Dimensions
(W x D x H) 66 x 107 x 152 mm 66 x 107 x 152 mm
Weight 255g 300g
Power
Requirements Dual 12~48V DC, 24V AC
Power
Consumption
Max. 5.3
watts/18BTU
(Ethernet full
loading)
Max. 6.3
watts/21.4BTU
(Ethernet full
loading)
Standards Conformance
Regulatory
Compliance FCC Part 15 Class A, CE
Stability Testing
IEC60068-2-32 (free fall)
IEC60068-2-27 (shock)
IEC60068-2-6 (vibration)
3. Hardware Introduction
3.1 Switch Front Panel
The front panel of the consists of Industrial Ethernet Switch
Ethernet interfaces and LED indicators.
Front View
P1 P2 Fau lt
2
4
6
8
10
12
14
16
1
3
5
7
9
11
13
15
ACTLNK
100
P1 P2 Fau lt
2
4
6
8
10
12
14
16
1
3
5
7
9
11
13
15
1000X
1000T
ACTLNK
1000
ACTLNK
100
17
17
18
18
Figure1:
ISW-1600T Front View
Figure2:
IFGS-1822TF Front View
Per Gigabit RJ45/SFP Combo Interface
(Port-17~Port-18 of IFGSW-1822TF)
LED FunctionColor
LNK/
ACT Green
Lights to indicate the link through that port is
successfully established.
Blinking to indicate that the switch is actively
sending or receiving data over that port.
O to indicates that the port is linked down.
1000
Speed Amber
Lights to indicate that the port is operating at
1000Mbps.
O to indicates that the port is operating at
10/100Mbps.
O to indicates that the port is linked down.
3.3 Switch Upper Panel
The upper panel of the Industrial Ethernet Switch consists of one
terminal block connector within two power input and one relay
ouput.
Max. fault loading: 24V, 1A
V1+ V1- V2+ V2-
PWR1 PWR2Fault
DC Input: 12-48V
, 2A max.
AC Input: 24V
, 1A max.
1 2 3 4 5 6
Figure3: ISW-1600T and IFGS-1822TF Top View
- 9 -
- 10 -
- 11 -
- 12 - - 13 - - 14 -
3.4 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of
Industrial Ethernet Switch is used for two DC redundant power
inputs. Please follow the steps below to insert the power wire.
When performing any of the procedures like inserting
the wires or tightening the wire-clamp screws, make
sure the power is OFF to prevent from getting an
electric shock.
1. Insert positive and negative DC power wires into contacts 1 and
2 for POWER 1, or contacts 5 and 6 for POWER 2.
Max. fault loading: 24V, 1A
V1+ V1- V2+ V2-
PWR1 PWR2Fault
DC Input: 12-48V
, 2A max.
AC Input: 24V
, 1A max.
1 2 3 4 5 6
2. Tighten the wire-clamp screws for preventing the wires from
loosening.
1 2 3 64 5
Power 1 Fault Power 2
+ - + -
4. Installation
This section describes the functionalities of the Industrial Ethernet
Switchs components and guides you to installing it on the DIN rail
and wall. Please read this chapter completely before continuing.
Note
This following pictures show how to install the device.
However, the device in the picture is not ISW-1600T
or IFGS-1822TF.
4.1 DIN-rail Mounting Installation
2
1
Note
1. The wire gauge for the terminal block should be in
the range between 12 and 24 AWG.
2. The power input range is 12V ~ 48V DC and
supports 24V AC.
3. Use one power input when using 24V AC.
3.5 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. Inserting the wires, the
Industrial Ethernet Switch will detect the fault status of the power
failure and then forms an open circuit. The following illustration
shows an application example for wiring the fault alarm contacts.
123456
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Fault
Insert the wires into the fault alarm contacts
Note
1. The wire gauge for the terminal block should be in
the range between 12 and 24 AWG.
2. Alarm relay circuit accepts up to 24V DC,1A
4.2 Wall-mount Plate Mounting
4.3 Side Wall-mount Plate Mounting
5. Customer Support
Thank you for purchasing PLANET products. You can browse our
online FAQ resource on PLANET web site rst to check if it could
solve your issue. If you need more support information, please
contact PLANET switch support team.
PLANET online FAQ:
http://www.planet.com.tw/en/support/faq
Switch support team mail address:
support@planet.com.tw
Copyright © PLANET Technology Corp. 2019.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
FCC Warning
This equipment has been tested and found to comply with the
regulations for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed
and used in accordance with this user’s guide, may cause harmful
interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference, in which
case the user will be required to correct the interference at his own
expense.
CE Mark Warning
This is a Class A product. In a domestic environment, this product
may cause radio interference, in which case the user may be
required to take adequate measures.
WEEE Warning
To avoid the potential eects on the environment and
human health as a result of the presence of hazardous
substances in electrical and electronic equipment, end
users of electrical and electronic equipment should
understand the meaning of the crossed-out wheeled bin symbol. Do
not dispose of WEEE as unsorted municipal waste and have to
collect such WEEE separately.

Especificaciones del producto

Marca: Planet
Categoría: No categorizado
Modelo: ISW-1600T

¿Necesitas ayuda?

Si necesitas ayuda con Planet ISW-1600T haz una pregunta a continuación y otros usuarios te responderán




No categorizado Planet Manuales

No categorizado Manuales

Últimos No categorizado Manuales