Planet ISW-500T Manual de Usario

Lee a continuación 📖 el manual en español para Planet ISW-500T (4 páginas) en la categoría No categorizado. Esta guía fue útil para 3 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/4
- 1 - - 2 - - 3 - - 4 -
1. Package Contents
Thank you for purchasing PLANET industrial 5-/8-port 10/100TX
Compact Ethernet Switch, ISW-500T/800T. In the following section, the
term “Industrial Ethernet Switch” means the ISW-500T or ISW-800T.
Open the box of the Industrial Ethernet Switch and carefully unpack it.
The box should contain the following items:
Industrial Ethernet Switch x 1 User’s Manual x 1
DIN-rail Kit x 1 Wall-mount Kit x 1 RJ45 Dust Cap
ISW-500T x 5
ISW-800T x 8
If any of these are missing or damaged, please contact your dealer
immediately; if possible, retain the carton including the original packing
material, and use them again to repack the product in case there is a
need to return it to us for repair.
2.ProductSpecications
Product ISW-500T ISW-800T
Hardware Specications
Copper Ports 5 10/100BASE-TX RJ45
auto-MDI/MDI-X ports
8 10/100BASE-TX RJ45
auto-MDI/MDI-X ports
Switch Architecture Store-and-Forward
Switch Fabric 1Gbps (non-blocking) 1.6Gbps (non-blocking)
Throughput
(packet per second) 0.74Mpps@ 64 bytes 1.19Mpps@ 64 bytes
Address Table 1K entries, automatic source address learning
and aging
Shared Data Buer 448K bits
Flow Control IEEE 802.3x pause frame for full-duplex
Back pressure for half-duplex
ESD Protection 6KV DC
Enclosure IP30 metal case
Installation DIN-rail kit and wall-mount kit
Connector
Removable 6-pin terminal block for power input
Pin 1/2 for Power 1, Pin 3/4 for fault alarm, Pin
5/6 for Power 2
Alarm One relay output for power failure.
Alarm relay current carry ability: 1A @ 24V DC
LED Indicator
System:
Power 1 (Green), Power 2 (Green)
Fault Alarm (Red)
Per 10/100TX RJ45 Ports:
10/100 LNK/ACT (Green)
Dimensions
(W x D x H) 30 x 70 x 104 mm 41 x 70 x 115 mm
Weight 255g 300g
Power Requirements Dual 12~48V DC, 24V AC
Power Consumption Max. 2 watts/6.86BTU
(Ethernet full loading)
Max. 2.5 watts/8.57BTU
(Ethernet full loading)
Standards Conformance
Regulatory
Compliance FCC Part 15 Class A, CE
Stability Testing
IEC60068-2-32 (free fall)
IEC60068-2-27 (shock)
IEC60068-2-6 (vibration)
Standards Compliance
IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX/100BASE-FX
IEEE 802.3x ow control and back pressure
IEEE 802.1p Class of Service
IEEE 802.3az Energy Ecient Ethernet (EEE)
Environment
Operating
Temperature -40 ~ 75 degrees C
Storage Temperature -40 ~ 85 degrees C
Humidity 5 ~ 95% (non-condensing)
3. Hardware Introduction
3.1 Three-View Diagram
The three-view diagram of the Industrial Ethernet Switch consists
of ve or eight auto-sensing 10/100/BASE-TX RJ45 port and one
removable 6-pin terminal block. The LED indicators are also located
on the front panel.
104.00
30.00
70.00
18.00
9.00
91.00
52.00 52.00
50.00
30.00
28.00
48.80 40.00
18.00
40.00
18.00
147.00
Mounting Kit
Mounting Kit
DIN-Rail Kit
Unit: mm
Rear ViewSide View Side View
Top View
Front View
Bottom View
P1 P2 Fault
ACTLNK
10/100
1
2
3
4
5
Max . F ault Alarm Loa ding: 24V, 1A
DC Inp ut: 12-48V
, 0.17A max .
AC Inpu t: 24V
, 0.15A max .
Fault
V1+ V2 +
PWR 2PWR 1
Figure 1: ISW-500T Three-View Diagram
115.00
41.00
70.00
18.00
9.00
103.00
28.65
27.19
70.00
40.00 48.80 40.00
28.00 18.00 28.00
159.00
Top View
Front View
Mounting Kit
Mounting Kit
DIN-Rail Kit
Unit: mm
Rear View
Bottom View
Side View Side View
P1 P2 Fault
ACTLNK
10/100
1
2
3
4
5
6
7
8
Max . Fault Alar m Lo ading: 24V, 1A
DC In put: 12-48 V
, 0.2A max .
AC Inpu t: 24V
, 0.16A max .
Fault
V1+ V2 +
PWR 2PWR 1
Figure 2: ISW-800T Three-View Diagram
[ISW-500T]
1. Insert positive and negative DC power wires into contacts 1 and 2 for
Power 1, or 5 and 6 for Power 2.
Max. Fault Alarm Loading: 24V, 1A
DC nput: 12-48V
, 0.17A max.
AC I ut: 24V
, 0.15A max.
Fa ult
V1+ V2+
PWR2PWR1
1 2 3 4 5 6
Wire Range Wire Type Torque In-lbs (N.m)FW
12-24 AWG Str/Sol 5 (0.56)Cu 2
2. This product is intended to be supplied with a UL-listed power adapter
or power source, rated 24V AC 50/60Hz min. 0.15A or 12-48V DC
min. 0.17A, and Tma 75°C (max.).
3. Tighten the wire-clamp screws for preventing the wires from loos-
ening.
123456
Power 1 Fault Power 2
+ - + -
Note
1. The power input range is 12V ~ 48V DC and supports
24V AC.
2. Use one power input when using 24V AC.
Note
1. La plage d’entrée d’alimentation est de 12V ~ 48V DC
et prend en charge 24V AC.
2. Utilisez une entrée d’alimentation lorsque vous utilisez
24V AC.
[ISW-800T]
1. Insert positive and negative DC power wires into contacts 1 and 2 for
POWER 1, or contacts 5 and 6 for POWER.
Max. Fault Alarm Loading: 24V, 1A
D nput: 12-48V
, 0.2A max.
AC I ut: 24V
, 0.16A max.
Fa ult
V1+ V2+
PWR2PWR1
1 2 3 4 5 6
Wire Range Wire Type Torque In-lbs (N.m)FW
12-24 AWG Str/Sol 5 (0.56)Cu 2
2. This product is intended to be supplied with a UL-listed power adapter
or power source, rated 24V AC, 50/60Hz min. 0.16A or 12-48V DC,
min. 0.2A, and Tma 75°C (max.).
3. Tighten the wire-clamp screws for preventing the wires from loos-
ening.
123456
Power 1 Fault Power 2
+ - + -
Note
1. The power input range is 12V ~ 48V DC and supports
24V AC.
2. Use one power input when using 24V AC.
Note
1. La plage d’entrée d’alimentation est de 12V ~ 48V DC
et prend en charge 24V AC.
2. Utilisez une entrée d’alimentation lorsque vous utilisez
24V AC.
3.2 Front View
P1 P2 Fault
ACTLNK
10/100
1
2
3
4
5
P1 P2 Fault
ACTLNK
10/100
1
2
3
4
5
6
7
8
Figure 3: ISW-500T Front View ISW-800T Front ViewFigure 4:
3.3 LEDDenition:
System
LED Color Function
DC1 Green Lights to indicate DC power input 1 has power.
DC2 Green Lights to indicate DC power input 2 has power.
Fault Red Lights to indicate that AC or DC power has failed.
Per 10/100BASE-TX Port
LED Color Function
10/100
LNK/ACT Green
Lights
Indicating the port is running at
10/100Mbps speed and successfully
established.
Blinks Indicating that the switch is actively
sending or receiving data over that port.
3.4 Top View
Max. Fault Alarm Loading: 24V, 1A
DC Input: 12-48V
, 0.17A max.
AC Input: 24V
, 0.15A max.
Fa ult
V1+ V2+
PWR2PWR1
1 2 3 4 5 6
Figure 5: ISW-500T Top View
Max. Fault Alarm Loading: 24V, 1A
DC Input: 12-48V
, 0.2A max.
AC Input: 24V
, 0.16A max.
Fa ult
V1+ V2+
PWR2PWR1
1 2 3 4 5 6
Figure 6: ISW-800T Top View
3.5 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of Industrial
Ethernet Switch is used for two DC redundant power inputs. Please
follow the steps below to insert the power wire by professionals.
Caution
When performing any of the procedures like inserting the
wires or tightening the wire-clamp screws, make sure the
power is OFF to prevent from getting an electric shock.
Caution
Lorsque vous effectuez l’une des procédures telles que
l’insertion des fils ou le serrage des vis de serrage,
assurez-vous que l’alimentation est coupée pour éviter tout
choc électrique.
- 5 - - 6 - - 7 -
3.6 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. Inserting the wires, the Industrial
Ethernet Switch will detect the fault status of the power failure and then
forms an open circuit. The following illustration shows an application
example for wiring the fault alarm contacts.
1 2 3 4 5 6
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Fault
Insert the wires into the fault alarm contacts
Wire Range Wire Type Torque In-lbs (N.m)FW
12-24 AWG Str/Sol 5 (0.56)Cu 2
Alarm relay circuit accepts up to 24V DC, 1A.
3.7 Grounding the Device
Users MUST complete grounding wired with power cord adapter or
power supply source should be connected to a socket outlet with an
earthing connection; otherwise, a sudden lightning could cause fatal
damage to the device
Max. Fault Alarm Loading: 24V, 1A
DC Input: 12-48V
, 0.17A max.
AC Input: 24V
, 0.15A max.
Fault
V1+ V2+
PWR2PWR1
1 2 3 4 5 6
Note
EMD (Lightning) DAMAGE IS NOT CONVERED UNDER
WARRANTY.
Note
LES DOMMAGES EMD (éclair) NE SONT PAS PRIS SOUS
GARANTIE.
4. Installation
This section describes the functionalities of the Industrial Ethernet
Switch’s components and guides you to installing it on the DIN rail and
wall. Please read this chapter completely before continuing.
Note
This following pictures show the user how to install the
device, and the device is not ISW-500T or ISW-800T.
4.1 DIN-rail Mounting Installation
1
2
4.2 Wall-mount Plate Mounting
Mount on product or wall (Screw size and quantity: 4mm (L), 3mm
(dia.) and 4pcs); DIN-rail mount on product (Screw size and quantity:
4mm (L), 3mm (dia.) and 3pcs)
4.3 Side Wall-mount Plate Mounting
Caution
You must use the screws supplied with the wall-mounting
brackets. Damage caused to the parts by using incorrect
screws would invalidate your warranty.
Attention
Vous devez utiliser les vis fournies avec les supports
muraux. Les dommages causés aux pièces par l’utilisation
de vis incorrectes invalideraient votre garantie.
5. Customer Support
Thank you for purchasing PLANET products. You can browse our online
FAQ resource on PLANET web site rst to check if it could solve your
issue. If you need more support information, please contact PLANET
switch support team.
PLANET online FAQs:
http://www.planet.com.tw/en/support/faq.php
Support team mail address:
support @planet.com.tw
Copyright © PLANET Technology Corp. 2021.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
FCC Warning
This equipment has been tested and found to comply with the
regulations for a Class A digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in
accordance with this user’s guide, may cause harmful interference to
radio communications. Operation of this equipment in a residential area
is likely to cause harmful interference, in which case the user will be
required to correct the interference at his own expense.
Avertissement de la FCC
Cet équipement a été testé et jugé conforme à la réglementation pour
un appareil numérique de classe A, conformément à la partie 15 des
gles de la FCC. Ces limites sont conçues pour fournir une protection
PLANET TECHNOLOGY CORPORATION
e-mail: sales@planet.com.tw http://www.planet.com.tw
10F., No.96, Minquan Rd., Xindian Dist., New Taipei City, Taiwan, R.O.C. Tel:886-2- - -2- -2219 9518 Fax:886 2219 9528
EC Declaration of Conformity
For the following equipment:
*Type of Product : Industrial 5- -/8 Port 10/100TX Compact Ethernet Switch
*Model Number : ISW-500T, -8ISW 00T
* Produced by:
Manufacturer‘s Name : Planet Technology Corp.
Manufacturer‘s Address : 10F., N Xindian Dist.,o.96, Minquan Rd.,
New Taipei City 231, Taiwan, R.O.C.
is herewith confirmed to comply with the requirements set out in the Council Directive on the
Approximation of the Laws of the Member States relating to Electromagnetic Compatibility
D 2014/30 Uirective on ( /E ).
For the evaluation regarding the EMC, the following standards were applied:
EN 55032 (2015 + AC:2016)
EN 55024 (2010 + A1:2015)
Responsible for marking this declaration if the:
Manufacturer Authorized representative established within the EU
Authorized representative established within the EU (if applicable):
Company Name: Planet Technology Corp.
Company Address: 10F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan, R.O.C.
Person responsible for making this declaration
Name, Surname Kent Kang
Position / Title : Director
Taiwan
Apr. 12 18, 20
Place
Date
Legal Signature
raisonnable contre les interférences nuisibles lorsque l’équipement est
utilisé dans un environnement commercial. Cet équipement génère,
utilise et peut émettre de l’énergie radiofréquence et, s’il n’est pas
installé et utilisé conformément au présent guide de l’utilisateur,
peut causer des interférences nuisibles aux communications radio. Le
fonctionnement de ces équipements dans une zone résidentielle est
susceptible de provoquer des interférences préjudiciables, auquel cas
l’utilisateur sera tenu de corriger les interférences à ses propres frais.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may
cause radio interference, in which case the user may be required to take
adequate measures.
This equipment is compliant with Class A of CISPR 32. In a residential
environment this equipment may cause radio interference.
Avertissement de marquage CE
Il s’agit d’un produit de classe A. Dans un environnement domestique,
ce produit peut provoquer des interférences radio, auquel cas l’utilisateur
peut être tenu de prendre des mesures adéquates.
Cet équipement est conforme à la classe A du CISPR 32. Dans un
environnement sidentiel, cet équipement peut causer des interférences
radio.
WEEE Warning
To avoid the potential eects on the environment and human
health as a result of the presence of hazardous substances in
electrical and electronic equipment, end users of electrical and
electronic equipment should understand the meaning of the
crossed-out wheeled bin symbol. Do not dispose of WEEE as
unsorted municipal waste and have to collect such WEEE separately.
Avertissement WEEE
An déviter les eets potentiels sur l’environnement et la
santé humaine résultant de la présence de substances
dangereuses dans les équipements électriques et électroniques,
les utilisateurs naux d’équipements électriques et
électroniques devraient comprendre la signication du symbole
du bac à roulettes barré. Ne jetez pas les WEEE en tant que déchets
municipaux non triés et devez les collecter pament.

Especificaciones del producto

Marca: Planet
Categoría: No categorizado
Modelo: ISW-500T

¿Necesitas ayuda?

Si necesitas ayuda con Planet ISW-500T haz una pregunta a continuación y otros usuarios te responderán




No categorizado Planet Manuales

No categorizado Manuales

Últimos No categorizado Manuales