1. Package Contents
Thank you for purchasing PLANET Industrial Ethernet
Switch, ISW-501T/ISW-801T. In the following sections, the
term Industrial Ethernet Switch means the ISW-501T
or ISW-801T.
Open the box of the Industrial Ethernet Switch and carefully
unpack it. The box should contain the following items:
Industrial Ethernet
Switch x 1
User’s Manual x 1 RJ45 Dust
Cap x 5 (8)
DIN-rail Bracket w/
Screws x 1
Wall-mount Plate
w/Screws x 1 set
If any of these are missing or damaged, please contact
your dealer immediately; if possible, retain the carton
including the original packing material, and use them again
to repack the product in case there is a need to return it to
us for repair.
2.2 LED Indicators
LED Color Function
P1 Green Lit: indicates Power 1 has power.
P2 Green Lit: indicates Power 2 has power.
FAULT Green Lit: indicates either Power 1 or Power
2 has no power.
10/100
LNK/ACT Green
Lit: indicates the Switch is
successfully connecting to the
network at 100Mbps or 10Mbps.
O: indicates that the Switch is not
successfully connecting to the
network at 100Mbps or 10Mbps.
Blinking: indicates that the Switch is
actively sending or receiving data over
that port.
2.3 Switch Upper Panel
The upper panel of the Industrial Ethernet Switch consists
of one terminal block connector within two DC power
inputs.
2.6 Grounding the Device
Users MUST complete grounding wired with the device;
otherwise, a sudden lightning could cause fatal damage to
the device.
Max. fault loading: 24V, 1A
V1+ V2+
PWR1 PWR2Fault
DC Input: 12-48V
, 1.2A max.
AC Input: 24V
, 1.1A max.
1 2 3 4 5 6
Earth Ground
Note
EMD (Lightning) DAMAGE IS NOT CONVERED
UNDER WARRANTY.
2. Tighten the wire-clamp screws for preventing the wires
from loosening.
1 2 3 4 5 6
V1+ V1- V2+ V2-
Power 1 Power 2Fault
Note
1. The wire gauge for the terminal block should
be in the range between 12 and 24 AWG.
2. The power input range is DC 12V ~ 48V and
supports AC 24V.
3. Use one power input when using AC 24V.
2. Hardware Introduction
2.1 Switch Front Panel
The front panel of the Industrial Ethernet Switch consists of
Ethernet interfaces and LED indicators.
Front View
P1 P2 Fault
10 /10 0
ACT
LNK
2
3
4
5
1
P1 P2 Fault
6
7
8
5
2
3
4
1
10/100
ACT
LNK
Figure 1: ISW-501T Front
View
Figure 2: ISW-801T Front
View
Figure 3 shows the upper panel of the Industrial Ethernet
Switch.
Max. fault loading: 24V, 1A
V1+ V2+
PWR1 PWR2Fault
DC Input: 12-48V
, 1.2A max.
AC Input: 24V
, 1.1A max.
1 2 3 4 5 6
Figure 3: ISW-501T and ISW-801T Top View
2.4 Wiring the Power Inputs
The Upper Panel of the Industrial Ethernet Switch indicates
a DC inlet power socket and consis of one terminal block ts
connector within 6 contacts. Please follow the steps below
to insert the power wire.
1. Insert positive/negative DC power wires into Contacts 1
and 2 for Power 1, or 5 and 6 for Power 2.
Max. fault loading: 24V, 1A
V1+ V2+
PWR1 PWR2Fault
DC Input: 12-48V
, 1.2A max.
AC Input: 24V
, 1.1A max.
1 2 3 4 5 6
2.5 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal
block connector as the picture shows below. Inserting the
wires, the Industrial Ethernet Switch will detect the fault
status of the power failure, or port link failure and then
forms an open circuit. The following illustration shows an
application example for wiring the fault alarm contacts.
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Fault
Insert the wires into the fault alarm contacts
Note
1. The wire gauge for the terminal block should
be in the range between 12 and 24 AWG.
2. Alarm relay circuit accepts up to 24V, 1A
current (max.).
3. Installation
This section describes the functionalities of the Industrial
Ethernet Switch’s components and guides you to installing
it on the DIN rail and wall. Please read this chapter
completely before continuing.
Note
This following pictures show how to install the
device. However, the device in the picture is
not ISW-501T or ISW-801T.
3.1 DIN-rail Mounting Installation
1
2
3.2 Wall-mount Plate Mounting
- 9 -
- 10 -
- 11 -
- 12 - - 13 -
4. Product Specications
Model ISW-501T ISW-801T
Hardware Specications
10/100BASE-TX
Ports 5 8
LED Indicators
3 x LED for System and Power:
Green: DC Power 1
Green: DC Power 2
Green: Power Fault
1 x LED per Copper Port
Green: 10/100 LNK/ACT
Enclosure IP30-rated metal case
Dimensions
(W x D x H) 32 x 87 x 135mm
Weight 400g 428g
ESD Protection 6KV DC
Power
Requirements
12~48V DC, redundant power with
polarity reverse protection function,
24V AC power support
Power
Consumption/
Dissipation
1.6 watts/5.4BTU 2.1 watts/7.1BTU
Standards Conformance
Standards
Compliance
IEEE 802.3 Ethernet
IEEE 802.3u Fast Ethernet
IEEE 802.3x Full Duplex Flow Control
IEEE 802.3az Energy Ecient
Ethernet
Temperature Operating: -40~75 degrees C
Storage: -40~75 degrees C
Humidity Operating: 5% to 95%, Storage:
5% to 95% (non-condensing)
Regulatory
Compliance FCC Part 15 Class A, CE
Stability Testing
IEC60068-2-32 (free fall)
IEC60068-2-27 (shock)
IEC60068-2-6 (vibration)
Installation DIN-rail kit and wall-mount ear
Alarm
Provides one relay output for power
failure; Alarm relay current carry
ability: 1A @ DC 24V
Connector
Removable 6-pin terminal block
Pin 1/2 for Power 1; Pin 3/4 for fault
alarm; Pin 5/6 for Power 2
Switch Specications
Switch Processing
Scheme Store-and-Forward
Address Table 1K
Buer Memory Embedded 448K bits packet buer
Flow Control
Back pressure for half duplex,
IEEE 802.3x pause frame for full
duplex
Switch Fabric 1Gbps 1.6Gbps
Throughput (packet
per second) 0.74Mpps 1.19Mpps
5. Customer Support
Thank you for purchasing PLANET products. You can browse
our online FAQ resource at PLANET Web site rst to check
if it could solve your issue. If you need more support
information, please contact PLANET switch support team.
PLANET online FAQs:
http://www.planet.com.tw/en/support/faq
Switch support team mail address:
support@planet.com.tw
Copyright © PLANET Technology Corp. 2021.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
PLANET TECHNOLOGY CORPORATION
e-mail: sales@planet.com.tw http://www.planet.com.tw
10F., No.96, Minquan Rd., Xindian Dist., New Taipei City, Taiwan, R.O.C. Tel:886-2- -2219 9518 Fax:886-2-2219 9528-
EC Declaration of Conformity
For the following equipment:
*Type of Product : 5 -/8 Port 10/100TX Industrial Fast Ethernet Switch
*Model Number : ISW-501T, -8ISW 01T
* Produced by:
Manufacturer‘s Name : Planet Technology Corp.
Manufacturer‘s Address : 10F., No.96, Minquan Rd., Xindian Dist.,
New Taipei City 231, Taiwan, R.O.C.
is herewith confirmed to comply with the requirements set out in the Council Directive on the
Approximation of the Laws of the Member States relating to Electromagnetic Compatibility
Directive on (2014/30 U/E ).
For the evaluation regarding the EMC, the following standards were applied:
EN 55032 (2015 + AC:2016)
EN61000-3-2 (2014)
EN61000-3-3 (2013)
EN 55035 (2017)
Responsible for marking this declaration if the:
Manufacturer Authorized representative esta blished within the EU
Authorized representative established within the EU (if applicable):
Company Name: Planet Technology Corp.
Company Address: 10F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan, R.O.C.
Person responsible for making this declaration
Name, Surname Kent Kang
Position / Title : Director
Taiwan
May 25 18, 20
Place
Date
Legal Signature

Especificaciones del producto

Marca: Planet
Categoría: No categorizado
Modelo: ISW-801T

¿Necesitas ayuda?

Si necesitas ayuda con Planet ISW-801T haz una pregunta a continuación y otros usuarios te responderán




No categorizado Planet Manuales

No categorizado Manuales

Últimos No categorizado Manuales